Reference right ventricular systolic and diastolic function normalized to age, gender and body surface area from steady-state free precession cardiovascular magnetic resonance
The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Abstract
AIMS: Recent advances in cardiovascular magnetic resonance (CMR) include improved image quality with steady-state free precession (SSFP) sequences and advanced post-processing of high temporal resolution ventricular function. We used these techniques to establish the reference values for right ventricular (RV) volumes and function. METHODS AND RESULTS: We studied 120 healthy subjects (60 men, 60 women; from 20 to 80 years) after exclusion of cardiovascular abnormality. Data were generated from SSFP cines, with three-dimensional modelling. Gender, body surface area (BSA), and age were independent predictors of several RV parameters. Normalized RV mass (RVM) and absolute and normalized RV volumes decreased significantly with age, whereas ejection fraction increased. For diastolic variables, absolute and normalized early peak filling rate (PFR(E)) decreased and absolute and normalized active peak filling rate (PFR(A)) in males increased, with decreased PFR(E)/PFR(A). Increasing BSA was associated with increased RVM, volumes, and PFR(E). Gender significantly influenced absolute and normalized mass and volumes, and absolute and normalized PFR(A). CONCLUSION: These data using state-of-the-art CMR show that normal values of RV systolic and diastolic parameters vary significantly by gender, BSA, and age. Appropriate reference ranges normalized to all three variables should be used in the determination of normality or severity of abnormality of RV dimensions and function.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The right ventricular filling through the tricuspid valve has similar dynamics (Maceira et al., 2006b).”
From Thoroughly Calibrated Modular Agent-Based Model of the Human Cardiovascular and Renal Systems for Blood Pressure Regulation in Health and Disease (2021) · cites this paper as Maceira et al., 2006b
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Rapid Measurement of B-Type Natriuretic Peptide in the Emergency Diagnosis of Heart Failure
Maisel, A. S., Krishnaswamy, P., Nowak, R. M., McCord, J., Hollander, J. E., Duc, P., Omland, T., Storrow, A. B., Abraham, W. T., Wu, A. H. B., et al. (2002) · New England Journal of Medicine · doi:10.1056/nejmoa020233 · Cited by 3,362
Simplified calculation of body surface area
(1987) · New England Journal of Medicine · doi:10.1056/nejm198710223171717 · Cited by 3,238 · cited 5×
“5 22 (15, 29) 21 (14, 28) 21 (14, 28) 20 (13, 27) 20 (13, 27) 19 (12, 26)”
InfluentialGrothues, F., Smith, G. C., Moon, J. C. C., Bellenger, N. G., Collins, P., Klein, H. U., & Pennell, D. J. (2002) · The American Journal of Cardiology · doi:10.1016/s0002-9149(02)02381-0 · Cited by 1,267
Self-citationMaceira, A., Prasad, S., Khan, M., & Pennell, D. (2006) · Journal of Cardiovascular Magnetic Resonance · doi:10.1080/10976640600572889 · Cited by 847
Self-citationGrothues, F., Moon, J. C., Bellenger, N. G., Smith, G. S., Klein, H. U., & Pennell, D. J. (2004) · American Heart Journal · doi:10.1016/j.ahj.2003.10.005 · Cited by 776
Self-citationAlfakih, K., Plein, S., Thiele, H., Jones, T., Ridgway, J. P., & Sivananthan, M. U. (2003) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.10262 · Cited by 732
Lorenz, C., Walker, E., Morgan, V., Klein, S., & Graham, T. (1999) · Journal of Cardiovascular Magnetic Resonance · doi:10.3109/10976649909080829 · Cited by 717
Bellenger, N., Davies, L. C., Francis, J., Coats, A., & Pennell, D. (2000) · Journal of Cardiovascular Magnetic Resonance · doi:10.3109/10976640009148691 · Cited by 681
Self-citationCine MR Angiography of the Heart with Segmented True Fast Imaging with Steady-State Precession
Carr, J. C., Simonetti, O., Bundy, J., Li, D., Pereles, S., & Finn, J. P. (2001) · Radiology · doi:10.1148/radiology.219.3.r01jn44828 · Cited by 468
Measurement of right and left ventricular volumes in healthy individuals with cine MR imaging.
Sechtem, U., Pflugfelder, P. W., Gould, R. G., Cassidy, M. M., & Higgins, C. B. (1987) · Radiology · doi:10.1148/radiology.163.3.3575717 · Cited by 407
Cited by
Otto, C. M., Nishimura, R. A., Bonow, R. O., Carabello, B. A., Erwin, J. P., Gentile, F., Jneid, H., Krieger, E. V., Mack, M., McLeod, C., et al. (2021) · Circulation · doi:10.1161/cir.0000000000000923 · Cited by 3,686
Recommendations for Noninvasive Evaluation of Native Valvular Regurgitation
Zoghbi, W. A., Adams, D., Bonow, R. O., Enriquez-Sarano, M., Foster, E., Grayburn, P. A., Hahn, R. T., Han, Y., Hung, J., Lang, R. M., et al. (2017) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2017.01.007 · Cited by 3,556
2014 AHA/ACC Guideline for the Management of Patients With Valvular Heart Disease
Nishimura, R. A., Otto, C. M., Bonow, R. O., Carabello, B. A., Erwin, J. P., Guyton, R. A., O’Gara, P. T., Ruiz, C. E., Skubas, N. J., Sorajja, P., et al. (2014) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2014.02.536 · Cited by 3,523
Nishimura, R. A., Otto, C. M., Bonow, R. O., Carabello, B. A., Erwin, J. P., Guyton, R. A., O’Gara, P. T., Ruiz, C. E., Skubas, N. J., Sorajja, P., et al. (2014) · Circulation · doi:10.1161/cir.0000000000000031 · Cited by 2,905
Otto, C. M., Nishimura, R. A., Bonow, R. O., Carabello, B. A., Erwin, J. P., Gentile, F., Jneid, H., Krieger, E. V., Mack, M., McLeod, C., et al. (2021) · Circulation · doi:10.1161/cir.0000000000000932 · Cited by 2,449
2020 ACC/AHA Guideline for the Management of Patients With Valvular Heart Disease
Otto, C. M., Nishimura, R. A., Bonow, R. O., Carabello, B. A., Erwin, J. P., Gentile, F., Jneid, H., Krieger, E. V., Mack, M., McLeod, C., et al. (2021) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2020.11.018 · Cited by 1,982
2020 ACC/AHA Guideline for the Management of Patients With Valvular Heart Disease: Executive Summary
Otto, C. M., Nishimura, R. A., Bonow, R. O., Carabello, B. A., Erwin, J. P., Gentile, F., Jneid, H., Krieger, E. V., Mack, M., McLeod, C., et al. (2021) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2020.11.035 · Cited by 1,075
2014 AHA/ACC guideline for the management of patients with valvular heart disease
Nishimura, R. A., Otto, C. M., Bonow, R. O., Carabello, B. A., Erwin, J. P., Guyton, R. A., O’Gara, P. T., Ruiz, C. E., Skubas, N. J., Sorajja, P., et al. (2014) · The Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/j.jtcvs.2014.05.014 · Cited by 989
Normal values for cardiovascular magnetic resonance in adults and children
Kawel-Boehm, N., Maceira, A., Valsangiacomo-Buechel, E. R., Vogel-Claussen, J., Turkbey, E. B., Williams, R., Plein, S., Tee, M., Eng, J., & Bluemke, D. A. (2015) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/s12968-015-0111-7 · Cited by 746
Self-citationLeft-Dominant Arrhythmogenic Cardiomyopathy
Sen-Chowdhry, S., Syrris, P., Prasad, S. K., Hughes, S. E., Merrifield, R., Ward, D., Pennell, D. J., & McKenna, W. J. (2008) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2008.09.019 · Cited by 661
Self-citationKawel-Boehm, N., Hetzel, S. J., Ambale-Venkatesh, B., Captur, G., Francois, C. J., Jerosch-Herold, M., Salerno, M., Teague, S. D., Valsangiacomo-Buechel, E., van der Geest, R. J., et al. (2020) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/s12968-020-00683-3 · Cited by 610
Zoghbi, W. A., Asch, F. M., Bruce, C., Gillam, L. D., Grayburn, P. A., Hahn, R. T., Inglessis, I., Islam, A. M., Lerakis, S., Little, S. H., et al. (2019) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2019.01.003 · Cited by 439
2020 Clinical practice guidelines for Chronic heart failure
Russian Society of Cardiology (RSC) (2020) · Russian Journal of Cardiology · doi:10.15829/1560-4071-2020-4083 · Cited by 395
Pennell, D. J., Udelson, J. E., Arai, A. E., Bozkurt, B., Cohen, A. R., Galanello, R., Hoffman, T. M., Kiernan, M. S., Lerakis, S., Piga, A., et al. (2013) · Circulation · doi:10.1161/cir.0b013e31829b2be6 · Cited by 394
Self-citationKawut, S. M., Lima, J. A. C., Barr, R. G., Chahal, H., Jain, A., Tandri, H., Praestgaard, A., Bagiella, E., Kizer, J. R., Johnson, W. C., et al. (2011) · Circulation · doi:10.1161/circulationaha.110.985515 · Cited by 390
Lahm, T., Douglas, I. S., Archer, S. L., Bogaard, H. J., Chesler, N. C., Haddad, F., Hemnes, A. R., Kawut, S. M., Kline, J. A., Kolb, T. M., et al. (2018) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201806-1160st · Cited by 343
Gulati, A., Ismail, T. F., Jabbour, A., Alpendurada, F., Guha, K., Ismail, N. A., Raza, S., Khwaja, J., Brown, T. D. H., Morarji, K., et al. (2013) · Circulation · doi:10.1161/circulationaha.113.002518 · Cited by 342
Self-citationKirk, R., Dipchand, A. I., Rosenthal, D. N., Addonizio, L., Burch, M., Chrisant, M., Dubin, A., Everitt, M., Gajarski, R., Mertens, L., et al. (2014) · The Journal of Heart and Lung Transplantation · doi:10.1016/j.healun.2014.06.002 · Cited by 340
Cardiovascular Magnetic Resonance
Pennell, D. J. (2010) · Circulation · doi:10.1161/circulationaha.108.811547 · Cited by 338
Self-citationSCMR Position Paper (2020) on clinical indications for cardiovascular magnetic resonance
Leiner, T., Bogaert, J., Friedrich, M. G., Mohiaddin, R., Muthurangu, V., Myerson, S., Powell, A. J., Raman, S. V., & Pennell, D. J. (2020) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/s12968-020-00682-4 · Cited by 328
Self-citationPeng, P., Lekadir, K., Gooya, A., Shao, L., Petersen, S. E., & Frangi, A. F. (2016) · Magnetic Resonance Materials in Physics, Biology and Medicine · doi:10.1007/s10334-015-0521-4 · Cited by 281
Hachulla, A.-L., Launay, D., Gaxotte, V, de Groote, P., Lamblin, N., Devos, P., Hatron, P.-Y., Beregi, J.-P., & Hachulla, E. (2009) · Annals of the Rheumatic Diseases · doi:10.1136/ard.2008.095836 · Cited by 280
Maceira, A. M., Cosín-Sales, J., Roughton, M., Prasad, S. K., & Pennell, D. J. (2010) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/1532-429x-12-65 · Cited by 274
Self-citation2020 ACC/AHA guideline for the management of patients with valvular heart disease
Otto, C. M., Nishimura, R. A., Bonow, R. O., Carabello, B. A., Erwin, J. P., Gentile, F., Jneid, H., Krieger, E. V., Mack, M., McLeod, C., et al. (2021) · The Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/j.jtcvs.2021.04.002 · Cited by 279
Right Ventricular Systolic Dysfunction in Young Adults Born Preterm
Lewandowski, A. J., Bradlow, W. M., Augustine, D., Davis, E. F., Francis, J., Singhal, A., Lucas, A., Neubauer, S., McCormick, K., & Leeson, P. (2013) · Circulation · doi:10.1161/circulationaha.113.002583 · Cited by 264
The echocardiographic assessment of the right ventricle: what to do in 2010?
Jurcut, R., Giusca, S., La Gerche, A., Vasile, S., Ginghina, C., & Voigt, J.-U. (2010) · European Journal of Echocardiography · doi:10.1093/ejechocard/jep234 · Cited by 249
“The thickness of the RV free wall is in the range of only 3– 5 mm,(13,14) and the RV mass is approximately one-fourth of that of the LV.(15,16) Still, owing to the lower impedance and greater distensibility of the pulmonary artery bed, the RV can pump blood at”
BackgroundMethodInfluentialLai, W. W., Gauvreau, K., Rivera, E. S., Saleeb, S., Powell, A. J., & Geva, T. (2008) · The International Journal of Cardiovascular Imaging · doi:10.1007/s10554-008-9314-4 · Cited by 238
“Partly as a consequence of the limitations of 2D echocardiography, cardiac MRI has emerged as the ‘‘gold standard’’ method for the clinical assessment of RV size and function [8, 9].”
MethodTanner, M. A., Galanello, R., Dessi, C., Smith, G. C., Westwood, M. A., Agus, A., Pibiri, M., Nair, S. V., Walker, J. M., & Pennell, D. J. (2008) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/1532-429x-10-12 · Cited by 238
Self-citationMaffessanti, F., Muraru, D., Esposito, R., Gripari, P., Ermacora, D., Santoro, C., Tamborini, G., Galderisi, M., Pepi, M., & Badano, L. P. (2013) · Circulation: Cardiovascular Imaging · doi:10.1161/circimaging.113.000706 · Cited by 235
Cardiovascular Magnetic Resonance in Arrhythmogenic Right Ventricular Cardiomyopathy Revisited
Sen-Chowdhry, S., Prasad, S. K., Syrris, P., Wage, R., Ward, D., Merrifield, R., Smith, G. C., Firmin, D. N., Pennell, D. J., & McKenna, W. J. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2006.07.045 · Cited by 235
Self-citationBuechel, E. V., Kaiser, T., Jackson, C., Schmitz, A., & Kellenberger, C. J. (2009) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/1532-429x-11-19 · Cited by 228
Weatherald, J., Boucly, A., Chemla, D., Savale, L., Peng, M., Jevnikar, M., Jaïs, X., Taniguchi, Y., O’Connell, C., Parent, F., et al. (2018) · Circulation · doi:10.1161/circulationaha.117.029254 · Cited by 226
Marcus, F. I., Zareba, W., Calkins, H., Towbin, J. A., Basso, C., Bluemke, D. A., Estes, N. A. M., Picard, M. H., Sanborn, D., Thiene, G., et al. (2009) · Heart Rhythm · doi:10.1016/j.hrthm.2009.03.013 · Cited by 213
“(32,33) This is beginning to be addressed as a result of this study.”
BackgroundPetersen, S. E., Khanji, M. Y., Plein, S., Lancellotti, P., & Bucciarelli-Ducci, C. (2019) · European Heart Journal - Cardiovascular Imaging · doi:10.1093/ehjci/jez232 · Cited by 212
Efficacy of deferasirox in reducing and preventing cardiac iron overload in β-thalassemia
Pennell, D. J., Porter, J. B., Cappellini, M. D., El-Beshlawy, A., Chan, L. L., Aydinok, Y., Elalfy, M. S., Sutcharitchan, P., Li, C.-K., Ibrahim, H., et al. (2010) · Blood · doi:10.1182/blood-2009-04-217455 · Cited by 195
Self-citationFour-dimensional Flow MRI: Principles and Cardiovascular Applications
Azarine, A., Garçon, P., Stansal, A., Canepa, N., Angelopoulos, G., Silvera, S., Sidi, D., Marteau, V., & Zins, M. (2019) · RadioGraphics · doi:10.1148/rg.2019180091 · Cited by 193
“Cardiac MRI is the current reference standard for measuring both right and left ventricular volumes (20,21).”
BackgroundTamborini, G., Marsan, N. A., Gripari, P., Maffessanti, F., Brusoni, D., Muratori, M., Caiani, E. G., Fiorentini, C., & Pepi, M. (2010) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2009.11.026 · Cited by 185
Marra, M. P., Leoni, L., Bauce, B., Corbetti, F., Zorzi, A., Migliore, F., Silvano, M., Rigato, I., Tona, F., Tarantini, G., et al. (2012) · Circulation: Arrhythmia and Electrophysiology · doi:10.1161/circep.111.964635 · Cited by 183
Imaging the right heart: the use of integrated multimodality imaging
Valsangiacomo Buechel, E. R., & Mertens, L. L. (2012) · European Heart Journal · doi:10.1093/eurheartj/ehr490 · Cited by 182
“Normal ageand gender-specific values for RV volumes and function have been published for the adult and the paediatric population.(63,64)”
BackgroundDucas, R. A., Elliott, J. E., Melnyk, S. F., Premecz, S., daSilva, M., Cleverley, K., Wtorek, P., Mackenzie, G. S., Helewa, M. E., & Jassal, D. S. (2014) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/1532-429x-16-1 · Cited by 182
“Whereas quantitative assessment of the RV using TTE is difficult due to its complex geometry, CMR serves as the gold standard for non-invasive assessment of this chamber due to its higher spatial resolution and low intra- and inter-observer variability [42].”
BackgroundMethodAune, E., Baekkevar, M., Roislien, J., Rodevand, O., & Otterstad, J. E. (2009) · European Journal of Echocardiography · doi:10.1093/ejechocard/jep054 · Cited by 170
“The CV was calculated as SD of the differences divided by the mean of the variable under consideration.(13) The analyses were implemented using SPSS 16.”
MethodStrocchi, M., Augustin, C. M., Gsell, M. A. F., Karabelas, E., Neic, A., Gillette, K., Razeghi, O., Prassl, A. J., Vigmond, E. J., Behar, J. M., et al. (2020) · PLoS ONE · doi:10.1371/journal.pone.0235145 · Cited by 112
“Despite high variations in both our cohort LV volumes and literature values, these were significantly higher than values reported in the literature for healthy controls (136 ±21mL [75]).”
ResultCardiac Magnetic Resonance Imaging for the Evaluation of Ventricular Function
Sarwar, A., Shapiro, M. D., Abbara, S., & Cury, R. C. (2008) · Seminars in Roentgenology · doi:10.1053/j.ro.2008.02.004 · Cited by 26
Roudijk, R. W., Verheul, L., Bosman, L. P., Bourfiss, M., Breur, J. M. P. J., Slieker, M. G., Blank, A. C., Dooijes, D., van der Heijden, J. F., van den Heuvel, F., et al. (2022) · JACC: Clinical Electrophysiology · doi:10.1016/j.jacep.2021.09.001 · Cited by 23
Kutumova, E., Kiselev, I., Sharipov, R., Lifshits, G., & Kolpakov, F. (2021) · Frontiers in Physiology · doi:10.3389/fphys.2021.746300 · Cited by 16
Metadata
- Authors
- Maceira, A. M., Prasad, S. K., Khan, M., & Pennell, D. J.
- Venue
- European Heart Journal
- Publisher
- Oxford University Press (OUP)
- Published
- 2006-11-13
- Volume
- 27
- Issue
- 23
- Pages
- 2879-2888
- ISSN
- 0195-668X (ISSN-L)
- 1522-9645
- OpenAlex
- W2073420794
- Cited by
- 561
- References
- 18
- FWCI
- 10.06
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.