Pulmonary vein isolation using an occluding cryoballoon for circumferential ablation: feasibility, complications, and short-term outcome
Open accessThe DOI matches its Crossref record; 40 of the 40 references it cites were found in a registry or an index.
Abstract
AIMS: To assess safety, feasibility and short term outcome of pulmonary vein (PV) isolation in paroxysmal atrial fibrillation (AF) with a cryoballoon. METHODS: We consecutively treated 57 patients with a double lumen 23 or 28 mm cryoballoon. The acute results, complications and follow-up over the first three months were analysed, using a comprehensive and intensive follow-up period. RESULTS: During 57 procedures, 185 of 220 targeted PV's were successfully isolated using the cryoballoon (84%) (balloon group, 33 patients). In 33 veins (15%) an additional segmental isolation (hybrid group, 24 patients) was necessary with a standard cryocatheter to achieve isolation. The average procedure times were respectively 211 +/- 108 and 261 +/- 83 minutes (NS), the average fluoroscopy times 52 +/- 36 and 66 +/- 33 minutes (NS). The number of balloon applications did not differ between both groups: respectively a median 9 (4-18) and 10 (5-17) (NS). We observed four phrenic nerve paralysis after ablation of the right superior PV: two resolved immediately after cessation of the cryoenergy, one recovered after 3 months, one persisted up to 6 months. A daily transtelephonic rhythm recording showed a significant drop in mean AF burden from 24% to 10%, 8% and 5% during the three consecutive months of follow-up (p < 0.01 versus baseline). No differences were observed between the treatment groups. 34 patients (60%) were completely free from AF after a single procedure. CONCLUSIONS: Balloon cryoablation of the pulmonary veins with additional segmental isolation if necessary, is a good approach for patients presenting with paroxysmal AF, showing a significant reduction in AF burden after a single procedure. The major complication seems to be phrenic nerve paralysis after ablation of the right superior PV, but this is potentially reversible over several months.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Lang, R. M., Bierig, M., Devereux, R. B., Flachskampf, F. A., Foster, E., Pellikka, P. A., Picard, M. H., Roman, M. J., Seward, J., Shanewise, J. S., et al. (2005) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2005.10.005 · Cited by 11,318
Spontaneous Initiation of Atrial Fibrillation by Ectopic Beats Originating in the Pulmonary Veins
Haïssaguerre, M., Jaïs, P., Shah, D. C., Takahashi, A., Hocini, M., Quiniou, G., Garrigue, S., Le Mouroux, A., Le Métayer, P., & Clémenty, J. (1998) · New England Journal of Medicine · doi:10.1056/nejm199809033391003 · Cited by 7,975
Cappato, R., Calkins, H., Chen, S.-A., Davies, W., Iesaka, Y., Kalman, J., Kim, Y.-H., Klein, G., Natale, A., Packer, D., et al. (2010) · Circulation Arrhythmia and Electrophysiology · doi:10.1161/circep.109.859116 · Cited by 2,852
Cappato, R., Calkins, H., Chen, S.-A., Davies, W., Iesaka, Y., Kalman, J., Kim, Y.-H., Klein, G., Packer, D., & Skanes, A. (2005) · Circulation · doi:10.1161/01.cir.0000157153.30978.67 · Cited by 1,305
Oral, H., Scharf, C., Chugh, A., Hall, B., Cheung, P., Good, E., Veerareddy, S., Pelosi, F., & Morady, F. (2003) · Circulation · doi:10.1161/01.cir.0000095796.45180.88 · Cited by 896
Pappone, C., Oral, H., Santinelli, V., Vicedomini, G., Lang, C. C., Manguso, F., Torracca, L., Benussi, S., Alfieri, O., Hong, R., et al. (2004) · Circulation · doi:10.1161/01.cir.0000131866.44650.46 · Cited by 871
Pappone, C., Oreto, G., Rosanio, S., Vicedomini, G., Tocchi, M., Gugliotta, F., Salvati, A., Dicandia, C., Calabrò, M. P., Mazzone, P., et al. (2001) · Circulation · doi:10.1161/hc4601.098517 · Cited by 863
Catheter Ablation of Paroxysmal Atrial Fibrillation Initiated by Non–Pulmonary Vein Ectopy
Lin, W.-S., Tai, C.-T., Hsieh, M.-H., Tsai, C.-F., Lin, Y.-K., Tsao, H.-M., Huang, J.-L., Yu, W.-C., Yang, S.-P., Ding, Y.-A., et al. (2003) · Circulation · doi:10.1161/01.cir.0000074206.52056.2d · Cited by 752
Lower Incidence of Thrombus Formation With Cryoenergy Versus Radiofrequency Catheter Ablation
Khairy, P., Chauvet, P., Lehmann, J., Lambert, J., Macle, L., Tanguay, J.-F., Sirois, M. G., Santoianni, D., & Dubuc, M. (2003) · Circulation · doi:10.1161/01.cir.0000058706.82623.a1 · Cited by 507
Circular mapping and ablation of thepulmonary vein for treatment of atrial fibrillation
Marrouche, N. F., Dresing, T., Cole, C., Bash, D., Saad, E., Balaban, K., Pavia, S. V., Schweikert, R., Saliba, W., Abdul-Karim, A., et al. (2002) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(02)01972-1 · Cited by 399
Clinical significance of early recurrences of atrial fibrillation after pulmonary vein isolation
Oral, H., Knight, B. P., Özaydın, M., Tada, H., Chugh, A., Hassan, S., Scharf, C., Lai, S. W. K., Greenstein, R., Pelosi, F., et al. (2002) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(02)01939-3 · Cited by 365
Pappone, C., Manguso, F., Vicedomini, G., Gugliotta, F., Santinelli, O., Ferro, A., Gulletta, S., Sala, S., Sora, N., Paglino, G., et al. (2004) · Circulation · doi:10.1161/01.cir.0000147186.83715.95 · Cited by 352
Phrenic Nerve Injury After Atrial Fibrillation Catheter Ablation
Sacher, F., Monahan, K. H., Thomas, S. P., Davidson, N., Adragao, P., Sanders, P., Hocini, M., Takahashi, Y., Rotter, M., Rostock, T., et al. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2006.02.050 · Cited by 344
Left Atrial–Esophageal Fistula Following Radiofrequency Catheter Ablation of Atrial Fibrillation
SCANAVACCA, M. I., D'ÁVILA, A., PARGA, J., & SOSA, E. (2004) · Journal of Cardiovascular Electrophysiology · doi:10.1046/j.1540-8167.2004.04083.x · Cited by 313
Esophageal perforation during left atrial radiofrequency ablation: Is the risk too high?
Doll, N., Borger, M. A., Fabricius, A., Stephan, S., Gummert, J., Mohr, F. W., Hauss, J., Kottkamp, H., & Hindricks, G. (2003) · The Journal of Thoracic and Cardiovascular Surgery · doi:10.1067/mtc.2003.165 · Cited by 313
Esophageal injury during radiofrequency ablation for atrial fibrillation
Gillinov, A. M., Pettersson, G., & Rice, T. W. (2001) · The Journal of Thoracic and Cardiovascular Surgery · doi:10.1067/mtc.2001.118041 · Cited by 293
Natale, A., Pisano, E., Shewchik, J., Bash, D., Fanelli, R., Potenza, D., Santarelli, P., Schweikert, R., White, R., Saliba, W., et al. (2000) · Circulation · doi:10.1161/01.cir.102.16.1879 · Cited by 275
Saad, E. B., Marrouche, N. F., Saad, C. P., Ha, E., Bash, D., White, R. D., Rhodes, J., Prieto, L., Martin, D. O., Saliba, W. I., et al. (2003) · Annals of Internal Medicine · doi:10.7326/0003-4819-138-8-200304150-00010 · Cited by 269
Sarabanda, A. V., Bunch, T. J., Johnson, S. B., Mahapatra, S., Milton, M. A., Leite, L. R., Bruce, G. K., & Packer, D. L. (2005) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2005.07.046 · Cited by 218
Tse, H.-F., Reek, S., Timmermans, C., Lee, K. L.-F., Geller, J. C., Rodriguez, L.-M., Ghaye, B., Ayers, G. M., Crijns, H. J. G. M., Klein, H. U., et al. (2003) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(03)00788-5 · Cited by 200
WAZNI, O. M., ROSSILLO, A., MARROUCHE, N. F., SAAD, E. B., MARTIN, D. O., BHARGAVA, M., BASH, D., BEHEIRY, S., WEXMAN, M., POTENZA, D., et al. (2005) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2005.40480.x · Cited by 176
BERTAGLIA, E., STABILE, G., SENATORE, G., ZOPPO, F., TURCO, P., AMELLONE, C., DE SIMONE, A., FAZZARI, M., & PASCOTTO, P. (2005) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2005.09516.x · Cited by 163
Sönmez, B., Demirsoy, E., Yağan, N., Unal, M. B., Arbatlı, H., Şener, D., Baran, T., & Ilkova, F. (2003) · The Annals of Thoracic Surgery · doi:10.1016/s0003-4975(03)00006-7 · Cited by 145
Transvenous Catheter Ice Mapping and Cryoablation of the Atrioventricular Node in Dogs
Dubuc, M., Roy, D., Thibault, B., Ducharme, A., Tardif, J., VILLEMAIRE, C., Leung, T. K., & Talajic, M. R. (1999) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.1999.tb00353.x · Cited by 143
Rotter, M., Takahashi, Y., Sanders, P., Haı̈ssaguerre, M., Jaı̈s, P., Hsu, L., Sacher, F., Pasquié, J., Clémenty, J., & Hocini, M. (2005) · European Heart Journal · doi:10.1093/eurheartj/ehi172 · Cited by 141
Rodriguez, L., Leunissen, J. D. M., HOEKSTRA, A., Korteling, B.-J., Smeets, J. L. R. M., TIMMERMANS, G., Vos, M. A., Daemen, M. J. A. P., & Wellens, H. J. J. (1998) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.1998.tb00883.x · Cited by 133
Long-term single procedure efficacy of catheter ablation of atrial fibrillation
Cheema, A., Vasamreddy, C. R., Dalal, D., Marine, J. E., Dong, J., Henrikson, C. A., SPRAGG, D. D., Cheng, A., Nazarian, S., Sinha, S. K., et al. (2006) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-006-9005-9 · Cited by 133
Khankirawatana, B., Khankirawatana, S., & Porter, T. R. (2004) · American Heart Journal · doi:10.1016/j.ahj.2003.03.001 · Cited by 111
Delayed cure despite early recurrence after pulmonary vein isolation for atrial fibrillation
O’Donnell, D., FURNISS, S. S., Dunuwille, A., & Bourke, J. P. (2003) · The American Journal of Cardiology · doi:10.1016/s0002-9149(02)03005-9 · Cited by 102
Flutter Localized to the Anterior Left Atrium After Catheter Ablation of Atrial Fibrillation
JAÏS, P., SANDERS, P., HSU, L., HOCINI, M., SACHER, F., TAKAHASHI, Y., ROTTER, M., ROSTOCK, T., BORDACHAR, P., REUTER, S., et al. (2006) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2005.00292.x · Cited by 82
Atrial Fibrillation Ablation: Reaching the Mainstream
Fisher, J. D., Spinelli, M. A., Mookherjee, D., KRUMERMAN, A. K., & Palma, E. (2006) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2006.00388.x · Cited by 75
Antz, M., Chun, K. R. J., Ouyang, F. O., & Kück, K. (2006) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2006.00589.x · Cited by 38
Theuns, D. A. M. J., Kimman, G. P., Szili‐Törok, T., Res, J., & Jordaens, L. J. L. M. (2004) · EP Europace · doi:10.1016/j.eupc.2003.11.006 · Cited by 36
Self-citationTranscatheter Cryoablation of Ventricular Myocardium in Dogs
Wadhwa, M. K., Rahme, M. M., Dobak, J. D., Li, H., Wolf, P. L., Chen, P., & Feld, G. K. (2000) · Journal of Interventional Cardiac Electrophysiology · doi:10.1023/a:1009872917450 · Cited by 36
Clinical significance of early recurrences of atrial fibrillation after pulmonary vein isolation
Oral, H., Knight, B. P., & Ozaydin, M. (2002) · ACC Current Journal Review · doi:10.1016/s1062-1458(02)00952-2 · Cited by 27
Nonarrhythmogenicity of therapeutic cryothermic lesions of the myocardium
Wetstein, L., Mark, R., Kaplan, A., Mitamura, H., Sauermelch, C. F., & Michelson, E. L. (1985) · Journal of Surgical Research · doi:10.1016/0022-4804(85)90123-4 · Cited by 23
Saad, E., MARROUCHE, N. F., & Saad, S. P. (2003) · ACC Current Journal Review · doi:10.1016/s1062-1458(03)00313-1 · Cited by 21
Marrouche, N. F., Dresing, T., & Cole, C. (2003) · ACC Current Journal Review · doi:10.1016/s1062-1458(02)01055-3 · Cited by 20
SCHOLTEN, M. F., Thornton, A. S., Mekel, J. M., & Jordaens, L. J. L. M. (2006) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-006-6334-7 · Cited by 7
Self-citationElectrical isolation of pulmonary veins using cryothermal energy: study design and initial results.
SCHOLTEN, M. F., Kimman, G., Janse, P., Thornton, A. S., Theuns, D. A. M. J., & Jordaens, L. J. L. M. (2003) · PubMed Central · Cited by 6
Self-citation
Cited by
Calkins, H., Hindricks, G., Cappato, R., Kim, Y.-H., Saad, E. B., Aguinaga, L., Akar, J. G., Badhwar, V., Brugada, J., Camm, J., et al. (2017) · Heart Rhythm · doi:10.1016/j.hrthm.2017.05.012 · Cited by 2,755
Calkins, H., Hindricks, G., Cappato, R., Kim, Y.-H., Saad, E. B., Aguinaga, L., Akar, J. G., Badhwar, V., Brugada, J., Camm, J., et al. (2018) · EP Europace · doi:10.1093/europace/eux274 · Cited by 1,164
Circumferential Pulmonary Vein Isolation With the Cryoballoon Technique
Neumann, T., Vogt, J., Schumacher, B., Dorszewski, A., Kuniss, M., Neuser, H., Kurzidim, K., Berkowitsch, A., Koller, M., Heintze, J., et al. (2008) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2008.04.021 · Cited by 475
Andrade, J. G., Khairy, P., Guerra, P. G., Deyell, M. W., Rivard, L., Macle, L., Thibault, B., Talajic, M., Roy, D., & Dubuc, M. (2011) · Heart Rhythm · doi:10.1016/j.hrthm.2011.03.050 · Cited by 360
Chun, K.-R. J., Schmidt, B., Metzner, A., Tilz, R., Zerm, T., Koster, I., Furnkranz, A., Koektuerk, B., Konstantinidou, M., Antz, M., et al. (2008) · European Heart Journal · doi:10.1093/eurheartj/ehn570 · Cited by 350
Metadata
- Authors
- Van Belle, Y., Janse, P., Rivero-Ayerza, M. J., Thornton, A. S., Jessurun, E. R., Theuns, D., & Jordaens, L.
- Venue
- European Heart Journal
- Publisher
- Oxford University Press (OUP)
- Published
- 2007-08-02
- Volume
- 28
- Issue
- 18
- Pages
- 2231-2237
- ISSN
- 0195-668X (ISSN-L)
- 1522-9645
- OpenAlex
- W2112050838
- Cited by
- 297
- References
- 40
- FWCI
- 14.90
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.