What is the real atrial fibrillation burden after catheter ablation of atrial fibrillation? A prospective rhythm analysis in pacemaker patients with continuous atrial monitoring
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
AIMS: Rhythm follow-up after catheter ablation of atrial fibrillation (AF ablation) is mainly based on Holter electrocardiogramm (ECG), tele-ECG or on patients symptoms. However, studies using 7-day Holter or tele-ECG follow-up revealed a significant number of asymptomatic recurrences. Thus, the aim of this study was to analyse continuous atrial recordings in pacemaker patients with an incorporated Holter function before and after AF ablation in order to determine all AF recurrences and thereby the 'real' success rates. METHODS AND RESULTS: The study comprised 37 patients (64.6 +/- 10 years) with prior pacemaker/implantable cardioverter defibrillator (ICD) implantation including an atrial Holter function referred for AF ablation. Holter data were obtained and correlated to patients' symptoms before and every 3-month after AF ablation. AF recurrence was defined as an atrial high frequency episode of less than 330 ms (180 b.p.m.) lasting longer than 30 s. The ablation procedure consisted of pulmonary vein isolation (PVI) in patients with paroxysmal atrial fibrillation (PAF, n = 20) and additional substrate modification aiming arrhythmia termination in patients with persistent or inducible AF after PVI as well as in patients with a history of long-lasting persistent AF (PersAF, n = 17). The mean atrial Holter monitoring period was 7.4 +/- 3.3 months before and 13.5 +/- 4.2 months after ablation with an overall AF burden of 33.7% prior to ablation. During follow-up, AF burden decreased from 17.3-0.65% (P = 0.001) in PAF patients and from 57.4 to 13.9% (P = 0.024) in patients with PersAF. Complete AF freedom was observed in 85% (17 patients) of PAF patients and 59% (10 patients) in patients with PersAF. The absence of symptoms correlated well with documented freedom of AF. CONCLUSION: In the present study we could show, that freedom from AF can be achieved by catheter ablation in a high percentage of patients even with PersAF. Continuous atrial monitoring reveals AF ablation success rates comparable with those assessed by clinical evaluation. Symptomatic freedom of AF correlated well with the actual freedom of AF at least in this highly symptomatic patient cohort.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hindricks, G., Piorkowski, C., Tanner, H., Kobza, R., Gerds-Li, J.-H., Carbucicchio, C., & Kottkamp, H. (2005) · Circulation · doi:10.1161/circulationaha.104.518837 · Cited by 506 · cited 1×
“In concert with previous reports, the present study revealed a considerable higher number of documented AF episodes after AF ablation as compared with lone anamnestic survey exploring AF recurrences.(7,14) In a study using tele-ECG follow-up after AF ablation, we observed 46% of asymptomatic AF episodes.”
Prevention of atrial fibrillation after cardioversion: results of the PAFAC trial
FETSCH, T. (2004) · European Heart Journal · doi:10.1016/j.ehj.2004.04.015 · Cited by 334
Suppression of paroxysmal atrial tachyarrhythmias—results of the SOPAT trial
PATTEN, M., MAAS, R., BAUER, P., LUDERITZ, B., SONNTAG, F., DLUZNIEWSKI, M., HATALA, R., OPOLSKI, G., MULLER, H., & MEINERTZ, T. (2004) · European Heart Journal · doi:10.1016/j.ehj.2004.06.014 · Cited by 157
Self-citation
Cited by
Hindricks, G., Potpara, T., Dagres, N., Arbelo, E., Bax, J. J., Blomström-Lundqvist, C., Boriani, G., Castella, M., Dan, G.-A., Dilaveris, P. E., et al. (2021) · European Heart Journal · doi:10.1093/eurheartj/ehaa612 · Cited by 9,971
Calkins, H., Hindricks, G., Cappato, R., Kim, Y.-H., Saad, E. B., Aguinaga, L., Akar, J. G., Badhwar, V., Brugada, J., Camm, J., et al. (2017) · Heart Rhythm · doi:10.1016/j.hrthm.2017.05.012 · Cited by 2,755
Calkins, H., Hindricks, G., Cappato, R., Kim, Y.-H., Saad, E. B., Aguinaga, L., Akar, J. G., Badhwar, V., Brugada, J., Camm, J., et al. (2018) · EP Europace · doi:10.1093/europace/eux274 · Cited by 1,164
Self-citationVenice Chart International Consensus Document on Atrial Fibrillation Ablation
NATALE, A., RAVIELE, A., ARENTZ, T., CALKINS, H., CHEN, S., HAÏSSAGUERRE, M., HINDRICKS, G., HO, Y., KUCK, K. H., MARCHLINSKI, F., et al. (2007) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2007.00816.x · Cited by 406
Kuck, K.-H., Fürnkranz, A., Chun, K. R. J., Metzner, A., Ouyang, F., Schlüter, M., Elvan, A., Lim, H. W., Kueffer, F. J., Arentz, T., et al. (2016) · European Heart Journal · doi:10.1093/eurheartj/ehw285 · Cited by 352
Verma, A., Champagne, J., Sapp, J., Essebag, V., Novak, P., Skanes, A., Morillo, C. A., Khaykin, Y., & Birnie, D. (2013) · JAMA Internal Medicine · doi:10.1001/jamainternmed.2013.1561 · Cited by 315
“Postablation episodes were significantly shorter, decreasing to a median of 6 (interquartile range, 5-40) from 22 (10-202) minutes (P .”
InfluentialPiccini, J. P., Lopes, R. D., Kong, M. H., Hasselblad, V., Jackson, K., & Al-Khatib, S. M. (2009) · Circulation: Arrhythmia and Electrophysiology · doi:10.1161/circep.109.856633 · Cited by 290
Themistoclakis, S., Corrado, A., Marchlinski, F. E., Jais, P., Zado, E., Rossillo, A., Di Biase, L., Schweikert, R. A., Saliba, W. I., Horton, R., et al. (2010) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2009.11.039 · Cited by 276
Malmo, V., Nes, B. M., Amundsen, B. H., Tjonna, A.-E., Stoylen, A., Rossvoll, O., Wisloff, U., & Loennechen, J. P. (2016) · Circulation · doi:10.1161/circulationaha.115.018220 · Cited by 263
“By including 50 patients, the study was estimated to have sufficient power (0.84) to detect a 30% reduction from a mean time of 34±12% in AF.25 Change from baseline to follow-up within each group was analyzed with the paired-samples t test for normally distributed data and the Wilcoxon signed-rank test for nonnormally…”
MethodInfluentialLong‐Term Outcome of Atrial Fibrillation Ablation: Impact and Predictors of Very Late Recurrence
WOKHLU, A., HODGE, D. O., MONAHAN, K. H., ASIRVATHAM, S. J., FRIEDMAN, P. A., MUNGER, T. M., CHA, Y., SHEN, W., BRADY, P. A., BLUHM, C. M., et al. (2010) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2010.01786.x · Cited by 190
Hanke, T., Charitos, E. I., Stierle, U., Karluss, A., Kraatz, E., Graf, B., Hagemann, A., Misfeld, M., & Sievers, H. H. (2009) · Circulation · doi:10.1161/circulationaha.108.838474 · Cited by 121
Monitoring capabilities of cardiac rhythm management devices
Andrikopoulos, G., Tzeis, S., Theodorakis, G., & Vardas, P. (2010) · Europace · doi:10.1093/europace/eup317 · Cited by 5
Metadata
- Authors
- Steven, D., Rostock, T., Lutomsky, B., Klemm, H., Servatius, H., Drewitz, I., Friedrichs, K., Ventura, R., Meinertz, T., & Willems, S.
- Venue
- European Heart Journal
- Publisher
- Oxford University Press (OUP)
- Published
- 2008-03-16
- Volume
- 29
- Issue
- 8
- Pages
- 1037-1042
- ISSN
- 0195-668X (ISSN-L)
- 1522-9645
- OpenAlex
- W1974103997
- Cited by
- 88
- References
- 3
- FWCI
- 8.58
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.