Randomized trial of three rapamycin-eluting stents with different coating strategies for the reduction of coronary restenosis
Open accessThe DOI matches its Crossref record; 36 of the 36 references it cites were found in a registry or an index.
Abstract
AIMS: The objective of this study was to assess the non-inferiority, in terms of anti-restenotic efficacy, of both biodegradable-polymer (BP) and polymer-free (PF) stents compared with permanent-polymer rapamycin-eluting (PP; Cypher) stent. METHODS AND RESULTS: Patients with de novo coronary lesions in native vessels were randomly assigned to receive a BP stent, a PF stent or a PP stent. The primary endpoint was in-stent late lumen loss at follow-up angiogram. A total of 605 patients were enrolled: 202 patients received BP stents, 202 were treated with PP stents, and 201 received PF stents. Repeat angiography was available for 492 patients (81.3%). Mean late lumen loss at 6-8-month angiographic follow-up was 0.17 +/- 0.45 mm in the BP stent group, 0.23 +/- 0.46 mm in the PP cohort, and 0.47 +/- 0.56 mm in the PF stent group. The BP stent met pre-specified criteria for non-inferiority (P < 0.001), whereas the PF stent did not (P = 0.94). There were no differences in safety outcomes. CONCLUSION: Both BP and PF stents have a 1-year safety profile similar to that of the PP stent. Whereas the PF stent provided an inferior efficacy, the BP stent is at least as effective as the PP stent in terms of anti-restenotic efficacy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Clinical End Points in Coronary Stent Trials: A Case for Standardized Definitions
Cutlip, D. E., Windecker, S., Mehran, R., Boam, A., Cohen, D. J., van Es, G.-A., Gabriel Steg, P., Morel, M.-A., Mauri, L., Vranckx, P., et al. (2007) · Circulation · doi:10.1161/circulationaha.106.685313 · Cited by 5,497 · cited 1×
“Stent thrombosis was classified according to recently agreed Academic Research Consortium criteria.(30)”
MethodMoses, J. W., Leon, M. B., Popma, J. J., Fitzgerald, P. J., Holmes, D. R., O'Shaughnessy, C., Caputo, R. P., Kereiakes, D. J., Williams, D. O., Teirstein, P. S., et al. (2003) · New England Journal of Medicine · doi:10.1056/nejmoa035071 · Cited by 4,224 · cited 1×
“This threshold allowed for the preservation of 80% of reduction in late lumen loss observed previously with rapamycin-eluting stent compared with bare-metal stent.(6) With a power of 80% and a one-sided a-level of 0.”
MethodMorice, M.-C., Serruys, P. W., Sousa, J. E., Fajadet, J., Ban Hayashi, E., Perin, M., Colombo, A., Schuler, G., Barragan, P., Guagliumi, G., et al. (2002) · New England Journal of Medicine · doi:10.1056/nejmoa012843 · Cited by 4,033
Iakovou, I. (2005) · JAMA · doi:10.1001/jama.293.17.2126 · Cited by 3,132
Pathology of Drug-Eluting Stents in Humans
Joner, M., Finn, A. V., Farb, A., Mont, E. K., Kolodgie, F. D., Ladich, E., Kutys, R., Skorija, K., Gold, H. K., & Virmani, R. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2006.03.042 · Cited by 2,744
Daemen, J., Wenaweser, P., Tsuchida, K., Abrecht, L., Vaina, S., Morger, C., Kukreja, N., Jüni, P., Sianos, G., Hellige, G., et al. (2007) · The Lancet · doi:10.1016/s0140-6736(07)60314-6 · Cited by 1,757
Images in Cardiovascular Medicine
(2012) · Wilderness & Environmental Medicine · doi:10.1016/j.wem.2012.05.013 · Cited by 1,519
Virmani, R., Guagliumi, G., Farb, A., Musumeci, G., Grieco, N., Motta, T., Mihalcsik, L., Tespili, M., Valsecchi, O., & Kolodgie, F. D. (2004) · Circulation · doi:10.1161/01.cir.0000116202.41966.d4 · Cited by 1,469
Late thrombosis in drug-eluting coronary stents after discontinuation of antiplatelet therapy
McFadden, E. P., Stabile, E., Regar, E., Cheneau, E., Ong, A. T., Kinnaird, T., Suddath, W. O., Weissman, N. J., Torguson, R., Kent, K. M., et al. (2004) · The Lancet · doi:10.1016/s0140-6736(04)17275-9 · Cited by 1,436
Outcomes associated with drug-eluting and bare-metal stents: a collaborative network meta-analysis
Stettler, C., Wandel, S., Allemann, S., Kastrati, A., Morice, M. C., Schömig, A., Pfisterer, M. E., Stone, G. W., Leon, M. B., de Lezo, J. S., et al. (2007) · The Lancet · doi:10.1016/s0140-6736(07)61444-5 · Cited by 1,428 · cited 1×
“– 37 In addition, a number of meta-analyses have confirmed that a potential safety and efficacy differential may exist in favour of sirolimus-eluting stents when compared with paclitaxel-eluting stents.(5,38,39) The significant improvement in anti-restenotic efficacy derived from the delay in rapamycin release associa…”
BackgroundSelf-citationEllis, S. G., Vandormael, M. G., Cowley, M. J., DiSciascio, G., Deligonul, U., Topol, E. J., & Bulle, T. M. (1990) · Circulation · doi:10.1161/01.cir.82.4.1193 · Cited by 1,350
Angiographic Patterns of In-Stent Restenosis: Classification and Implications for Long-Term Outcome
Mehran, R., Dangas, G., Abizaid, A. S., Mintz, G. S., Lansky, A. J., Satler, L. F., Pichard, A. D., Kent, K. M., Stone, G. W., & Leon, M. B. (1999) · Circulation · doi:10.1161/01.cir.100.18.1872 · Cited by 1,258 · cited 2×
“Restenosis morphology is categorized as described by Mehran et al.29 Stent thrombosis was classified according to recently agreed Academic Research Consortium criteria.30”
Methodvan der Giessen, W. J., Lincoff, A. M., Schwartz, R. S., van Beusekom, H. M. M., Serruys, P. W., Holmes, D. R., Ellis, S. G., & Topol, E. J. (1996) · Circulation · doi:10.1161/01.cir.94.7.1690 · Cited by 852
Sousa, J. E., Costa, M. A., Abizaid, A., Abizaid, A. S., Feres, F., Pinto, I. M. F., Seixas, A. C., Staico, R., Mattos, L. A., Sousa, A. G. M. R., et al. (2001) · Circulation · doi:10.1161/01.cir.103.2.192 · Cited by 793 · cited 1×
“The elution characteristics of the PP stent are reported elsewhere.(3,16) An oral loading dose of 600 mg clopidogrel was administered to all patients at least 2 h prior to the intervention, regardless of whether the patient was taking clopidogrel prior to admission.”
A hierarchical Bayesian meta-analysis of randomised clinical trials of drug-eluting stents
Babapulle, M. N., Joseph, L., Bélisle, P., Brophy, J. M., & Eisenberg, M. J. (2004) · The Lancet · doi:10.1016/s0140-6736(04)16850-5 · Cited by 645
Hypersensitivity Cases Associated With Drug-Eluting Coronary Stents
Nebeker, J. R., Virmani, R., Bennett, C. L., Hoffman, J. M., Samore, M. H., Alvarez, J., Davidson, C. J., McKoy, J. M., Raisch, D. W., Whisenant, B. K., et al. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2005.07.071 · Cited by 610
Sirolimus-Eluting and Paclitaxel-Eluting Stents for Coronary Revascularization
Windecker, S., Remondino, A., Eberli, F. R., Jüni, P., Räber, L., Wenaweser, P., Togni, M., Billinger, M., Tüller, D., Seiler, C., et al. (2005) · New England Journal of Medicine · doi:10.1056/nejmoa051175 · Cited by 593
Finn, A. V., Kolodgie, F. D., Harnek, J., Guerrero, L. J., Acampado, E., Tefera, K., Skorija, K., Weber, D. K., Gold, H. K., & Virmani, R. (2005) · Circulation · doi:10.1161/circulationaha.104.508937 · Cited by 556
Lemos, P. A., Serruys, P. W., van Domburg, R. T., Saia, F., Arampatzis, C. A., Hoye, A., Degertekin, M., Tanabe, K., Daemen, J., Liu, T. K. K., et al. (2004) · Circulation · doi:10.1161/01.cir.0000109138.84579.fa · Cited by 543
Paclitaxel-Eluting or Sirolimus-Eluting Stents to Prevent Restenosis in Diabetic Patients
Dibra, A., Kastrati, A., Mehilli, J., Pache, J., Schühlen, H., von Beckerath, N., Ulm, K., Wessely, R., Dirschinger, J., & Schömig, A. (2005) · New England Journal of Medicine · doi:10.1056/nejmoa044372 · Cited by 523
Self-citationDesign and Analysis of Bioavailability and Bioequivalence Studies
Ziegel, E. R., Chow, S., & Liu, J. (1994) · Technometrics · doi:10.2307/1270260 · Cited by 490
Schömig, A., Dibra, A., Windecker, S., Mehilli, J., Suárez de Lezo, J., Kaiser, C., Park, S.-J., Goy, J.-J., Lee, J.-H., Di Lorenzo, E., et al. (2007) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2007.06.047 · Cited by 359 · cited 1×
“– 37 In addition, a number of meta-analyses have confirmed that a potential safety and efficacy differential may exist in favour of sirolimus-eluting stents when compared with paclitaxel-eluting stents.(5,38,39) The significant improvement in anti-restenotic efficacy derived from the delay in rapamycin release associa…”
BackgroundSelf-citationNew Frontiers in Cardiology: Drug-Eluting Stents: Part I
Sousa, J. E., Serruys, P. W., & Costa, M. A. (2003) · Circulation · doi:10.1161/01.cir.0000069330.41022.90 · Cited by 349
Levin, A. D., Vukmirovic, N., Hwang, C., & Edelman, E. R. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0400918101 · Cited by 285 · cited 1×
“There is well-documented evidence that rapamycin and paclitaxel differ significantly in terms of their anti-restenotic efficacy and cellular and molecular properties.(34) – 37 In addition, a number of meta-analyses have confirmed that a potential safety and efficacy differential may exist in favour of sirolimus-elutin…”
BackgroundKastrati, A., Dibra, A., Eberle, S., Mehilli, J., Suárez de Lezo, J., Goy, J.-J., Ulm, K., & Schömig, A. (2005) · JAMA · doi:10.1001/jama.294.7.819 · Cited by 282 · cited 1×
“– 37 In addition, a number of meta-analyses have confirmed that a potential safety and efficacy differential may exist in favour of sirolimus-eluting stents when compared with paclitaxel-eluting stents.(5,38,39) The significant improvement in anti-restenotic efficacy derived from the delay in rapamycin release associa…”
BackgroundSelf-citationKastrati, A., Dibra, A., & Eberle, S. (2005) · ACC Current Journal Review · doi:10.1016/j.accreview.2005.10.047 · Cited by 235
Self-citationSirolimus and Paclitaxel on Polymer-Based Drug-Eluting Stents
Wessely, R., Schömig, A., & Kastrati, A. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2005.09.047 · Cited by 214
Self-citationDrug eluting stents: an updated meta-analysis of randomised controlled trials
Roiron, C., Sanchez, P., Bouzamondo, A., Lechat, P., & Montalescot, G. (2006) · Heart · doi:10.1136/hrt.2005.061622 · Cited by 210
Design and Analysis of Bioavailability and Bioequivalence Studies.
Fearn, T., Chow, S. C., & Liu, J. P. (1994) · Biometrics · doi:10.2307/2533474 · Cited by 199
Grube, E., Sonoda, S., Ikeno, F., Honda, Y., Kar, S., Chan, C., Gerckens, U., Lansky, A. J., & Fitzgerald, P. J. (2004) · Circulation · doi:10.1161/01.cir.0000128850.84227.fd · Cited by 191 · cited 2×
“The first reports have shown promising results with DES using BPs in terms of their anti-restenotic efficacy.(22,23) The second strategy consists of the utilization of polymer-free (PF) DES platforms.”
MethodResultMehilli, J., Kastrati, A., Wessely, R., Dibra, A., Hausleiter, J., Jaschke, B., Dirschinger, J., & Schömig, A. (2006) · Circulation · doi:10.1161/circulationaha.105.575977 · Cited by 179
Self-citationPolymers, Drug Release, and Drug‐Eluting Stents
COMMANDEUR, S., VAN BEUSEKOM, H. M. M., & VAN DER GIESSEN, W. J. (2006) · Journal of Interventional Cardiology · doi:10.1111/j.1540-8183.2006.00198.x · Cited by 118 · cited 1×
“The potential safety implications both in terms of a reduced incidence of late acute stent thrombosis and an obviation of the need for prolonged thienopyridine therapy (and its attendant bleeding risks) are obvious and the concept inherently attractive.(40) Previous preliminary experience using a BP on an everolimus-e…”
Late Restenosis in Patients Receiving a Polymer-Coated Sirolimus-Eluting Stent
Wessely, R., Kastrati, A., & Schömig, A. (2005) · Annals of Internal Medicine · doi:10.7326/0003-4819-143-5-200509060-00119 · Cited by 81
Self-citationDibra, A., Kastrati, A., Mehilli, J., Pache, J., von Oepen, R., Dirschinger, J., & Schömig, A. (2005) · Catheterization and Cardiovascular Interventions · doi:10.1002/ccd.20400 · Cited by 70 · cited 1×
“A detailed description for creating the micropores and its rationale, as well as the specifics of the coating process involved, have been reported previously.(24,27) The BP matrix used in the BP stent arm is completely resorbed within 6–9 weeks.”
BackgroundSelf-citationBlaich, B., BelAiba, R. S., Merl, S., Görlach, A., Kastrati, A., Schömig, A., & Wessely, R. (2007) · Thrombosis and Haemostasis · doi:10.1160/th06-10-0586 · Cited by 66
Self-citationWessely, R., Kastrati, A., Mehilli, J., Dibra, A., Pache, J., & Schömig, A. (2007) · European Heart Journal · doi:10.1093/eurheartj/ehm425 · Cited by 30
Self-citation
Cited by
Stefanini, G. G., Byrne, R. A., Serruys, P. W., de Waha, A., Meier, B., Massberg, S., Juni, P., Schomig, A., Windecker, S., & Kastrati, A. (2012) · European Heart Journal · doi:10.1093/eurheartj/ehs086 · Cited by 384
Self-citationStefanini, G. G., Kalesan, B., Serruys, P. W., Heg, D., Buszman, P., Linke, A., Ischinger, T., Klauss, V., Eberli, F., Wijns, W., et al. (2011) · The Lancet · doi:10.1016/s0140-6736(11)61672-3 · Cited by 354
Garg, S., & Serruys, P. W. (2010) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2010.06.008 · Cited by 306
Smits, P. C., Hofma, S., Togni, M., Vázquez, N., Valdés, M., Voudris, V., Slagboom, T., Goy, J.-J., Vuillomenet, A., Serra, A., et al. (2013) · The Lancet · doi:10.1016/s0140-6736(12)61852-2 · Cited by 293
Navarese, E. P., Tandjung, K., Claessen, B., Andreotti, F., Kowalewski, M., Kandzari, D. E., Kereiakes, D. J., Waksman, R., Mauri, L., Meredith, I. T., et al. (2013) · BMJ · doi:10.1136/bmj.f6530 · Cited by 237
Metadata
- Authors
- Mehilli, J., Byrne, R. A., Wieczorek, A., Iijima, R., Schulz, S., Bruskina, O., Pache, J., Wessely, R., Schomig, A., Kastrati, A., & for the Intracoronary Stenting and Angiographic Restenosis Investigators - Test Efficacy of Rapamycin-eluting Stents with Different Polymer Coating Strategies (ISAR-TEST-3)
- Venue
- European Heart Journal
- Publisher
- Oxford University Press (OUP)
- Published
- 2008-07-10
- Volume
- 29
- Issue
- 16
- Pages
- 1975-1982
- ISSN
- 0195-668X (ISSN-L)
- 1522-9645
- OpenAlex
- W2156104055
- Cited by
- 196
- References
- 36
- FWCI
- 16.49
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.