Detection of acute changes in circulating troponin in the setting of transient stress test-induced myocardial ischaemia using an ultrasensitive assay: results from TIMI 35
Open accessThe DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Abstract
AIMS: To determine whether an ultrasensitive assay can permit quantification of changes in circulating cardiac troponin (Tn) in the setting of stress test-induced myocardial ischaemia. METHODS AND RESULTS: Blood samples were obtained before, immediately after, and 2 and 4 h after stress testing with nuclear perfusion imaging in 120 patients. Troponin was measured using commercial assays as well as with a novel, ultrasensitive cardiac TnI assay with a limit of detection of 0.2 pg/mL. Using the ultrasensitive assay, TnI was detectable in all patients before stress testing (median 4.4 pg/mL, interquartile range 3.1-8.6 pg/mL). By 4 h, troponin levels were unchanged in patients without ischaemia, whereas circulating levels had increased by a median of 1.4 pg/mL (24% increase) in patients with mild ischaemia (P = 0.002) and by 2.1 pg/mL (40% increase) in patients with moderate-to-severe ischaemia (P = 0.0006). In contrast, changes in troponin levels across patients in different ischaemic categories were indistinguishable using commercial troponin assays. When added to clinical factors, a >1.3 pg/mL increase in TnI using the ultrasensitive assay was an independent predictor of ischaemia (odds ratio 3.54, P = 0.007). CONCLUSION: Transient stress test-induced myocardial ischaemia is associated with a quantifiable increase in circulating troponin that is detectable with a novel, ultrasensitive TnI assay.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Universal Definition of Myocardial Infarction
Thygesen, K., Alpert, J. S., White, H. D., TASK FORCE MEMBERS: Chairpersons: Kristian Thygesen (Denmark), J. S. A. (., Biomarker Group: Allan S. Jaffe, C. (., ECG Group: Bernard Chaitman, C.-O. (., Imaging Group: Richard Underwood, C. (., Intervention Group: Jean-Pierre Bassand, C.-O. (., Clinical Investigation Group: Paul W. Armstrong, C. (., Global Perspective Group: Philip A. Poole-Wilson, C. (., et al. (2007) · Circulation · doi:10.1161/circulationaha.107.187397 · Cited by 4,230
Universal Definition of Myocardial Infarction
Thygesen, K., Alpert, J. S., & White, H. D. (2007) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2007.09.011 · Cited by 1,618
Latini, R., Masson, S., Anand, I. S., Missov, E., Carlson, M., Vago, T., Angelici, L., Barlera, S., Parrinello, G., Maggioni, A. P., et al. (2007) · Circulation · doi:10.1161/circulationaha.106.655076 · Cited by 709
It’s Time for a Change to a Troponin Standard
Jaffe, A. S., Ravkilde, J., Roberts, R., Naslund, U., Apple, F. S., Galvani, M., & Katus, H. (2000) · Circulation · doi:10.1161/01.cir.102.11.1216 · Cited by 643
Katus, H. A., Remppis, A., Scheffold, T., Diederich, K. W., & Kuebler, W. (1991) · The American Journal of Cardiology · doi:10.1016/0002-9149(91)90466-x · Cited by 556
Berman, D. S., Kiat, H., Friedman, J. D., Wang, F. P., Van Train, K., Matzer, L., Maddahi, J., & Germano, G. (1993) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(93)90557-h · Cited by 528
The Kaohsiung Journal of Medical Sciences
(2019) · The Kaohsiung Journal of Medical Sciences · doi:10.1002/(issn)2410-8650 · Cited by 446
Prevalence and Determinants of Troponin T Elevation in the General Population
Wallace, T. W., Abdullah, S. M., Drazner, M. H., Das, S. R., Khera, A., McGuire, D. K., Wians, F., Sabatine, M. S., Morrow, D. A., & de Lemos, J. A. (2006) · Circulation · doi:10.1161/circulationaha.105.609974 · Cited by 434
Self-citationApple, F. S., Wu, A. H. B., & Jaffe, A. S. (2002) · American Heart Journal · doi:10.1067/mhj.2002.124048 · Cited by 397
Evaluation of Imprecision for Cardiac Troponin Assays at Low-Range Concentrations
Panteghini, M., Pagani, F., Yeo, K.-T. J., Apple, F. S., Christenson, R. H., Dati, F., Mair, J., Ravkilde, J., Wu, A. H. B., & the Committee on Standardization of Markers of Cardiac Damage of the IFCC (2004) · Clinical Chemistry · doi:10.1373/clinchem.2003.026815 · Cited by 368
Acute changes in circulating natriuretic peptide levels in relation to myocardial ischemia
Sabatine, M. S., Morrow, D. A., de Lemos, J. A., Omland, T., Desai, M. Y., Tanasijevic, M., Hall, C., McCabe, C. H., & Braunwald, E. (2004) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2004.07.057 · Cited by 329
Self-citationNACB Writing Group Members, Apple, F. S., Jesse, R. L., Newby, L. K., Wu, A. H. B., & Christenson, R. H. (2007) · Circulation · doi:10.1161/circulationaha.107.182881 · Cited by 300
Ultrasensitive Flow-based Immunoassays Using Single-Molecule Counting
Todd, J., Freese, B., Lu, A., Held, D., Morey, J., Livingston, R., & Goix, P. (2007) · Clinical Chemistry · doi:10.1373/clinchem.2007.091181 · Cited by 289
Release of cardiac troponin in acute coronary syndromes: ischemia or necrosis?
Wu, A. H. B., & Ford, L. (1999) · Clinica Chimica Acta · doi:10.1016/s0009-8981(99)00078-9 · Cited by 164
Myocardial tissue troponins T and I
Fishbein, M. C., Wang, T. L., Matijasevic, M., Hong, L., & Apple, F. S. (2003) · Cardiovascular Pathology · doi:10.1016/s1054-8807(02)00188-6 · Cited by 142
Remppis, A. B. (1995) · Journal of Molecular and Cellular Cardiology · doi:10.1016/0022-2828(95)90086-1 · Cited by 127
Kurz, K., Giannitsis, E., Zehelein, J., & Katus, H. A. (2008) · Clinical Chemistry · doi:10.1373/clinchem.2007.097865 · Cited by 90
Feng, Y.-J., Chen, C., Fallon, J. T., Lai, T., Chen, L., Knibbs, D. R., Waters, D. D., & Wu, A. H. B. (1998) · American Journal of Clinical Pathology · doi:10.1093/ajcp/110.1.70 · Cited by 82
Vikenes, K., Westby, J., Matre, K., Kuiper, K. K. J., Farstad, M., & Nordrehaug, J. E. (2002) · International Journal of Cardiology · doi:10.1016/s0167-5273(02)00162-6 · Cited by 22
Me, A., Starkey, B. J., Ziada, A. M., Aa, A., Sh, S., & Ga, F. (2001) · PubMed · Cited by 13
Does the Serum Cardiac Troponin I Level Increase With Stress Test-Induced Myocardial Ischemia?
Choragudi, N. L., Aronow, W. S., Prakash, A. M., Kurup, S. K., Chiaramida, S. A., & Lucariello, R. J. (2002) · Heart Disease · doi:10.1097/00132580-200207000-00004 · Cited by 6
Cited by
2014 AHA/ACC Guideline for the Management of Patients With Non–ST-Elevation Acute Coronary Syndromes
Amsterdam, E. A., Wenger, N. K., Brindis, R. G., Casey, D. E., Ganiats, T. G., Holmes, D. R., Jaffe, A. S., Jneid, H., Kelly, R. F., Kontos, M. C., et al. (2014) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2014.09.017 · Cited by 3,595
Self-citationAmsterdam, E. A., Wenger, N. K., Brindis, R. G., Casey, D. E., Ganiats, T. G., Holmes, D. R., Jaffe, A. S., Jneid, H., Kelly, R. F., Kontos, M. C., et al. (2014) · Circulation · doi:10.1161/cir.0000000000000134 · Cited by 1,059
“Highly sensitive assays can identify cardiac troponin not only in the blood of patients with acute cardiac injury, but also in the blood of most healthy people.(64,68,70,166,176,177) As assay sensitivity increases, a greater proportion of patients will have detectable long-term elevations in troponin, thus requiring c…”
BackgroundSelf-citationSaunders, J. T., Nambi, V., de Lemos, J. A., Chambless, L. E., Virani, S. S., Boerwinkle, E., Hoogeveen, R. C., Liu, X., Astor, B. C., Mosley, T. H., et al. (2011) · Circulation · doi:10.1161/circulationaha.110.005264 · Cited by 755
Self-citationdeFilippi, C. R., de Lemos, J. A., Christenson, R. H., Gottdiener, J. S., Kop, W. J., Zhan, M., & Seliger, S. L. (2010) · JAMA · doi:10.1001/jama.2010.1708 · Cited by 715
Self-citationRecommendations for the use of cardiac troponin measurement in acute cardiac care
Thygesen, K., Mair, J., Katus, H., Plebani, M., Venge, P., Collinson, P., Lindahl, B., Giannitsis, E., Hasin, Y., Galvani, M., et al. (2010) · European Heart Journal · doi:10.1093/eurheartj/ehq251 · Cited by 628
Metadata
- Authors
- Sabatine, M. S., Morrow, D. A., de Lemos, J. A., Jarolim, P., & Braunwald, E.
- Venue
- European Heart Journal
- Publisher
- Oxford University Press (OUP)
- Published
- 2008-05-21
- Volume
- 30
- Issue
- 2
- Pages
- 162-169
- ISSN
- 0195-668X (ISSN-L)
- 1522-9645
- OpenAlex
- W2165025270
- Cited by
- 277
- References
- 21
- FWCI
- 16.28
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.