The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Ultrasensitive Flow-based Immunoassays Using Single-Molecule Counting
Abstract
Background: Immunoassay (IA) technology has expanded the clinical utility of protein biomarkers, but demands for increased sensitivity, dynamic reporting ranges, and small sample volumes have limited the potential clinical usefulness of many biomarkers. We assessed the performance, including limits of detection (LODs) and the dynamic reporting range, of an IA-based technology, Erenna Immunoassay System, for a series of biomarkers, including cardiac troponin I (cTnI). Methods: Erenna IAs were used with 10 different and clinically important biomarkers to ascertain the LOD with various sample sizes (10 μL to 200 μL). Results: The Erenna Immunoassay System generated LODs of 10–100 pg/L using 100 μL of sample. For cTnI, the LOD was 0.2 ng/L and a 10% CV was seen between 0.78 and 1.6 ng/L. Conclusions: The Erenna IA-based technology reproducibly measures protein biomarkers with detection limits of 10–100 pg/L, with a dynamic range of >4.5 logs in sample volumes of 50–150 μL.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Wu, A. H. B., Fukushima, N. H., Puskas, R., Todd, J., & Goix, P. (2006) · Clinical Chemistry · doi:10.1373/clinchem.2006.073163 · Cited by 138
Self-citationMeasurement of Cytokines in Clinical Samples Using Immunoassays: Problems and Pitfalls
Banks, R. E. (2000) · Critical Reviews in Clinical Laboratory Sciences · doi:10.1080/10408360091174187 · Cited by 72
Assays for cytokines using aptamers
Guthrie, J. W., Hamula, C. L. A., ZHANG, H., & Le, X. C. (2006) · Methods · doi:10.1016/j.ymeth.2006.01.001 · Cited by 56
Viral RNA and p24 Antigen as Markers of HIV Disease and Antiretroviral Treatment Success
Schüpbach, J. (2003) · International Archives of Allergy and Immunology · doi:10.1159/000074552 · Cited by 55
Blood cardiac troponin in toxic myocardial injury: archetype of a translational safety biomarker
O'Brien, P. J. (2006) · Expert Review of Molecular Diagnostics · doi:10.1586/14737159.6.5.685 · Cited by 55
Cited by
Rissin, D. M., Kan, C. W., Campbell, T. G., Howes, S. C., Fournier, D. R., Song, L., Piech, T., Patel, P. P., Chang, L., Rivnak, A. J., et al. (2010) · Nature Biotechnology · doi:10.1038/nbt.1641 · Cited by 2,119
How to use high-sensitivity cardiac troponins in acute cardiac care
Thygesen, K., Mair, J., Giannitsis, E., Mueller, C., Lindahl, B., Blankenberg, S., Huber, K., Plebani, M., Biasucci, L. M., Tubaro, M., et al. (2012) · European Heart Journal · doi:10.1093/eurheartj/ehs154 · Cited by 784
Prognostic Utility of Novel Biomarkers of Cardiovascular Stress: The Framingham Heart Study
Wang, T. J., Wollert, K. C., Larson, M. G., Coglianese, E., McCabe, E. L., Cheng, S., Ho, J. E., Fradley, M. G., Ghorbani, A., Xanthakis, V., et al. (2012) · Circulation · doi:10.1161/circulationaha.112.129437 · Cited by 482
Wilson, D. H., Rissin, D. M., Kan, C. W., Fournier, D. R., Piech, T., Campbell, T. G., Meyer, R. E., Fishburn, M. W., Cabrera, C., Patel, P. P., et al. (2016) · SLAS Technology · doi:10.1177/2211068215589580 · Cited by 470
Guo, K., Wustoni, S., Koklu, A., Díaz-Galicia, E., Moser, M., Hama, A., Alqahtani, A. A., Ahmad, A. N., Alhamlan, F. S., Shuaib, M., et al. (2021) · Nature Biomedical Engineering · doi:10.1038/s41551-021-00734-9 · Cited by 410
Metadata
- Authors
- Todd, J., Freese, B., Lu, A., Held, D., Morey, J., Livingston, R., & Goix, P.
- Venue
- Clinical Chemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 2007-11-01
- Volume
- 53
- Issue
- 11
- Pages
- 1990-1995
- ISSN
- 0009-9147 (ISSN-L)
- 1530-8561
- OpenAlex
- W1991461818
- Cited by
- 289
- References
- 5
- FWCI
- 3.23
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Ultrasensitive Flow-based Immunoassays Using Single-Molecule Counting. https://app.cochat.ai/papers/10.1373/clinchem.2007.091181
- The paper
- Todd, J., Freese, B., Lu, A., Held, D., Morey, J., Livingston, R., & Goix, P. (2007). Ultrasensitive Flow-based Immunoassays Using Single-Molecule Counting. Clinical Chemistry. https://doi.org/10.1373/clinchem.2007.091181
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.