Abstract
AIMS: To evaluate the effects of applying current sizing guidelines to different multislice computer tomography (MSCT) aortic annulus measurements on Corevalve (CRS) size selection. METHODS AND RESULTS: Multislice computer tomography annulus diameters [minimum: D(min); maximum: D(max); mean: D(mean) = (D(min) + D(max))/2; mean from circumference: D(circ); mean from surface area: D(CSA)] were measured in 75 patients referred for percutaneous valve replacement. Fifty patients subsequently received a CRS (26 mm: n = 22; 29 mm: n = 28). D(min) and D(max) differed substantially [mean difference (95% CI) = 6.5 mm (5.7-7.2), P < 0.001]. If D(min) were used for sizing 26% of 75 patients would be ineligible (annulus too small in 23%, too large in 3%), 48% would receive a 26 mm and 12% a 29 mm CRS. If D(max) were used, 39% would be ineligible (all annuli too large), 4% would receive a 26 mm, and 52% a 29 mm CRS. Using D(mean), D(circ), or D(CSA) most patients would receive a 29 mm CRS and 11, 16, and 9% would be ineligible. In 50 patients who received a CRS operator choice corresponded best with sizing based on D(CSA) and D(mean) (76%, 74%), but undersizing occurred in 20 and 22% of which half were ineligible (annulus too large). CONCLUSION: Eligibility varied substantially depending on the sizing criterion. In clinical practice both under- and oversizing were common. Industry guidelines should recognize the oval shape of the aortic annulus.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Webb, J. G., Pasupati, S., Humphries, K., Thompson, C., Altwegg, L., Moss, R., Sinhal, A., Carere, R. G., Munt, B., Ricci, D., et al. (2007) · Circulation · doi:10.1161/circulationaha.107.698258 · Cited by 1,016
Percutaneous Aortic Valve Implantation Retrograde From the Femoral Artery
Webb, J. G., Chandavimol, M., Thompson, C. R., Ricci, D. R., Carere, R. G., Munt, B. I., Buller, C. E., Pasupati, S., & Lichtenstein, S. (2006) · Circulation · doi:10.1161/circulationaha.105.582882 · Cited by 900
Pellikka, P. A., Sarano, M. E., Nishimura, R. A., Malouf, J. F., Bailey, K. R., Scott, C. G., Barnes, M. E., & Tajik, A. J. (2005) · Circulation · doi:10.1161/circulationaha.104.495903 · Cited by 864
Vahanian, A., Alfieri, O., Al-Attar, N., Antunes, M., Bax, J., Cormier, B., Cribier, A., De Jaegere, P., Fournial, G., Kappetein, A. P., et al. (2008) · European Heart Journal · doi:10.1093/eurheartj/ehn183 · Cited by 719
Self-citationTreatment of Calcific Aortic Stenosis With the Percutaneous Heart Valve
Cribier, A., Eltchaninoff, H., Tron, C., Bauer, F., Agatiello, C., Nercolini, D., Tapiero, S., Litzler, P.-Y., Bessou, J.-P., & Babaliaros, V. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2006.01.049 · Cited by 715
Grube, E., Laborde, J. C., Gerckens, U., Felderhoff, T., Sauren, B., Buellesfeld, L., Mueller, R., Menichelli, M., Schmidt, T., Zickmann, B., et al. (2006) · Circulation · doi:10.1161/circulationaha.106.639450 · Cited by 655
Piazza, N., de Jaegere, P., Schultz, C., Becker, A. E., Serruys, P. W., & Anderson, R. H. (2008) · Circulation: Cardiovascular Interventions · doi:10.1161/circinterventions.108.780858 · Cited by 651 · cited 2×
“the three caudal points of the crown shaped line of attachment of the leaflets.(10) Patient matrices provided by”
Self-citationCribier, A., Eltchaninoff, H., Tron, C., Bauer, F., Agatiello, C., Sebagh, L., Bash, A., Nusimovici, D., Litzler, P. Y., Bessou, J.-P., et al. (2004) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2003.11.026 · Cited by 644
Piazza, N., Grube, E., Gerckens, U., den Heijer, P., Linke, A., Luha, O., Ramondo, A., Ussia, G., Wenaweser, P., Windecker, S., et al. (2008) · EuroIntervention · doi:10.4244/eijv4i2a43 · Cited by 628
Self-citationJournal of Heart Valve Disease
(2024) · Journal of Heart Valve Disease · doi:10.47310/jhvd · Cited by 525
Noninvasive Evaluation of the Aortic Root With Multislice Computed Tomography
Tops, L. F., Wood, D. A., Delgado, V., Schuijf, J. D., Mayo, J. R., Pasupati, S., Lamers, F. P. L., van der Wall, E. E., Schalij, M. J., Webb, J. G., et al. (2008) · JACC: Cardiovascular Imaging · doi:10.1016/j.jcmg.2007.12.006 · Cited by 518 · cited 1×
“an idealized symmetrical aortic root, whereas in the present study the annulus was non-circular and often oval similar to other the findings of studies using 3D imaging modalities including 64-slice MSCT, 3D TTE, or cardiac magnetic resonance imaging (CMRI).(13) –17 We defined the annulus as a virtual ‘ring’ with thre…”
Is It Reasonable to Treat All Calcified Stenotic Aortic Valves With a Valved Stent?
Zegdi, R., Ciobotaru, V., Noghin, M., Sleilaty, G., Lafont, A., Latrémouille, C., Deloche, A., & Fabiani, J.-N. (2008) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2007.10.023 · Cited by 245
Role of Echocardiography in Percutaneous Aortic Valve Implantation
Moss, R. R., Ivens, E., Pasupati, S., Humphries, K., Thompson, C. R., Munt, B., Sinhal, A., & Webb, J. G. (2008) · JACC: Cardiovascular Imaging · doi:10.1016/j.jcmg.2007.09.004 · Cited by 232
Schultz, C. J., Weustink, A., Piazza, N., Otten, A., Mollet, N., Krestin, G., van Geuns, R. J., de Feyter, P., Serruys, P. W. J., & de Jaegere, P. (2009) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2009.04.075 · Cited by 201 · cited 1×
“Furthermore, compression of the semi-rigid circular frame of the CRS inflow in one plane (diameter) may lead to some expansion in the orthogonal plane (diameter) leading to an elliptical shape, because within the constraints of the design the CRS inflow may conform to an elliptical annulus apparently without adverse e…”
Self-citationDecision-making and outcomes in severe symptomatic aortic stenosis.
Charlson, E., Legedza, A., & Hamel, M. B. (2006) · PubMed · Cited by 176
Role of Multislice Computed Tomography in Transcatheter Aortic Valve Replacement
Wood, D. A., Tops, L. F., Mayo, J. R., Pasupati, S., Schalij, M. J., Humphries, K., Lee, M., Al Ali, A., Munt, B., Moss, R., et al. (2009) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2009.01.034 · Cited by 176
Willmann, J. K., Weishaupt, D., Lachat, M. L., Kobza, R., Roos, J. E., Seifert, B., Lüscher, T. F., Marinček, B., & Hilfiker, P. R. (2002) · Radiology · doi:10.1148/radiol.2251011703 · Cited by 171
Demonstration of left ventricular outflow tract eccentricity by 64-slice multi-detector CT
Doddamani, S., Grushko, M. J., Makaryus, A. N., Jain, V. R., Bello, R. A., Friedman, M. A., Ostfeld, R. J., Malhotra, D., Boxt, L. M., Haramati, L. B., et al. (2008) · International journal of cardiac imaging · doi:10.1007/s10554-008-9362-9 · Cited by 142
Doddamani, S., Bello, R. A., Friedman, M. A., Banerjee, A., Bowers, J. H., Kim, B., Vennalaganti, P. R., Ostfeld, R. J., Gordon, G. M., Malhotra, D., et al. (2007) · Echocardiography · doi:10.1111/j.1540-8175.2007.00479.x · Cited by 140
Long-Term Outcomes After Valve Replacement for Low-Gradient Aortic Stenosis
Kulik, A., Burwash, I. G., Kapila, V., Mesana, T. G., & Ruel, M. (2006) · Circulation · doi:10.1161/circulationaha.105.001180 · Cited by 112
Aortic Regurgitation: Assessment with 64-Section CT
Alkadhi, H., Desbiolles, L. M., Husmann, L., Plass, A., Leschka, S., Scheffel, H., Vachenauer, R., Schepis, T., Gaemperli, O., Flohr, T. G., et al. (2007) · Radiology · doi:10.1148/radiol.2451061523 · Cited by 110
Can Balloon Aortic Valvuloplasty Help Determine Appropriate Transcatheter Aortic Valve Size?
Babaliaros, V. C., Liff, D. A., Chen, E. P., Rogers, J. H., Brown, R. A., Thourani, V. H., Guyton, R. A., Lerakis, S., Stillman, A. E., Raggi, P., et al. (2008) · JACC: Cardiovascular Interventions · doi:10.1016/j.jcin.2008.06.010 · Cited by 70 · cited 2×
“In addition, both TTE and TOE tend to underestimate the diameter compared with surgical sizing or MSCT by 1–2 mm on average, most likely due to the difficulty in defining a measurement that cuts through the true centre of the annulus on 2D images.(11) –13,18 As a result, one might anticipate a higher prevalence of und…”
Clavel, M.-A. A., Dumont, É., Pîbarot, P., Doyle, D. J., Larochellière, R. D., Villeneuve, J., Bergeron, S., Couture, C. Y., & Rodés‐Cabau, J. (2009) · The Annals of Thoracic Surgery · doi:10.1016/j.athoracsur.2008.06.059 · Cited by 67
Tanaka, K., Makaryus, A. N., & Wolff, S. D. (2007) · Journal of Cardiovascular Magnetic Resonance · doi:10.1080/10976640701545479 · Cited by 57
Otten, A., van Domburg, R., van Gameren, M., Kappetein, A. P., Takkenberg, J. J. M., Bogers, A. J. J. C., Serruys, P. W. J. C., & de Jaegere, P. P. T. (2008) · EuroIntervention · doi:10.4244/eijv4i2a44 · Cited by 50
Self-citation
Cited by
2012 ACCF/AATS/SCAI/STS Expert Consensus Document on Transcatheter Aortic Valve Replacement
Holmes, D. R., Mack, M. J., Kaul, S., Agnihotri, A., Alexander, K. P., Bailey, S. R., Calhoon, J. H., Carabello, B. A., Desai, M. Y., Edwards, F. H., et al. (2012) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2012.01.001 · Cited by 749
Jilaihawi, H., Kashif, M., Fontana, G., Furugen, A., Shiota, T., Friede, G., Makhija, R., Doctor, N., Leon, M. B., & Makkar, R. R. (2012) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2011.11.045 · Cited by 480
Willson, A. B., Webb, J. G., LaBounty, T. M., Achenbach, S., Moss, R., Wheeler, M., Thompson, C., Min, J. K., Gurvitch, R., Norgaard, B. L., et al. (2012) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2011.12.015 · Cited by 407
Transcatheter aortic valve implantation: current and future approaches
Rodés-Cabau, J. (2012) · Nature Reviews Cardiology · doi:10.1038/nrcardio.2011.164 · Cited by 306
Kamat, A. M., Flaig, T. W., Grossman, H. B., Konety, B., Lamm, D., O'Donnell, M. A., Uchio, E., Efstathiou, J. A., & Taylor, J. A. (2015) · Nature Reviews Urology · doi:10.1038/nrurol.2015.58 · Cited by 252
Metadata
- Authors
- Schultz, C. J., Moelker, A., Piazza, N., Tzikas, A., Otten, A., Nuis, R. J., Neefjes, L. A., van Geuns, R. J., de Feyter, P., Krestin, G., Serruys, P. W., & de Jaegere, P. P. T.
- Venue
- European Heart Journal
- Publisher
- Oxford University Press (OUP)
- Published
- 2009-12-07
- Volume
- 31
- Issue
- 7
- Pages
- 849-856
- ISSN
- 0195-668X (ISSN-L)
- 1522-9645
- OpenAlex
- W1987271654
- Cited by
- 183
- References
- 25
- FWCI
- 13.84
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.