Three dimensional evaluation of the aortic annulus using multislice computer tomography: are manufacturer's guidelines for sizing for percutaneous aortic valve replacement helpful?
Open accessThe DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
Abstract
AIMS: To evaluate the effects of applying current sizing guidelines to different multislice computer tomography (MSCT) aortic annulus measurements on Corevalve (CRS) size selection. METHODS AND RESULTS: Multislice computer tomography annulus diameters [minimum: D(min); maximum: D(max); mean: D(mean) = (D(min) + D(max))/2; mean from circumference: D(circ); mean from surface area: D(CSA)] were measured in 75 patients referred for percutaneous valve replacement. Fifty patients subsequently received a CRS (26 mm: n = 22; 29 mm: n = 28). D(min) and D(max) differed substantially [mean difference (95% CI) = 6.5 mm (5.7-7.2), P < 0.001]. If D(min) were used for sizing 26% of 75 patients would be ineligible (annulus too small in 23%, too large in 3%), 48% would receive a 26 mm and 12% a 29 mm CRS. If D(max) were used, 39% would be ineligible (all annuli too large), 4% would receive a 26 mm, and 52% a 29 mm CRS. Using D(mean), D(circ), or D(CSA) most patients would receive a 29 mm CRS and 11, 16, and 9% would be ineligible. In 50 patients who received a CRS operator choice corresponded best with sizing based on D(CSA) and D(mean) (76%, 74%), but undersizing occurred in 20 and 22% of which half were ineligible (annulus too large). CONCLUSION: Eligibility varied substantially depending on the sizing criterion. In clinical practice both under- and oversizing were common. Industry guidelines should recognize the oval shape of the aortic annulus.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Webb, J. G., Pasupati, S., Humphries, K., Thompson, C., Altwegg, L., Moss, R., Sinhal, A., Carere, R. G., Munt, B., Ricci, D., et al. (2007) · Circulation · doi:10.1161/circulationaha.107.698258 · Cited by 1,016
Percutaneous Aortic Valve Implantation Retrograde From the Femoral Artery
Webb, J. G., Chandavimol, M., Thompson, C. R., Ricci, D. R., Carere, R. G., Munt, B. I., Buller, C. E., Pasupati, S., & Lichtenstein, S. (2006) · Circulation · doi:10.1161/circulationaha.105.582882 · Cited by 900
Pellikka, P. A., Sarano, M. E., Nishimura, R. A., Malouf, J. F., Bailey, K. R., Scott, C. G., Barnes, M. E., & Tajik, A. J. (2005) · Circulation · doi:10.1161/circulationaha.104.495903 · Cited by 864
Vahanian, A., Alfieri, O., Al-Attar, N., Antunes, M., Bax, J., Cormier, B., Cribier, A., De Jaegere, P., Fournial, G., Kappetein, A. P., et al. (2008) · European Heart Journal · doi:10.1093/eurheartj/ehn183 · Cited by 719
Self-citationTreatment of Calcific Aortic Stenosis With the Percutaneous Heart Valve
Cribier, A., Eltchaninoff, H., Tron, C., Bauer, F., Agatiello, C., Nercolini, D., Tapiero, S., Litzler, P.-Y., Bessou, J.-P., & Babaliaros, V. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2006.01.049 · Cited by 715
Grube, E., Laborde, J. C., Gerckens, U., Felderhoff, T., Sauren, B., Buellesfeld, L., Mueller, R., Menichelli, M., Schmidt, T., Zickmann, B., et al. (2006) · Circulation · doi:10.1161/circulationaha.106.639450 · Cited by 655
Piazza, N., de Jaegere, P., Schultz, C., Becker, A. E., Serruys, P. W., & Anderson, R. H. (2008) · Circulation: Cardiovascular Interventions · doi:10.1161/circinterventions.108.780858 · Cited by 651 · cited 2×
“the three caudal points of the crown shaped line of attachment of the leaflets.(10) Patient matrices provided by”
Self-citationCribier, A., Eltchaninoff, H., Tron, C., Bauer, F., Agatiello, C., Sebagh, L., Bash, A., Nusimovici, D., Litzler, P. Y., Bessou, J.-P., et al. (2004) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2003.11.026 · Cited by 644
Piazza, N., Grube, E., Gerckens, U., den Heijer, P., Linke, A., Luha, O., Ramondo, A., Ussia, G., Wenaweser, P., Windecker, S., et al. (2008) · EuroIntervention · doi:10.4244/eijv4i2a43 · Cited by 628
Self-citationJournal of Heart Valve Disease
(2024) · Journal of Heart Valve Disease · doi:10.47310/jhvd · Cited by 525
Cited by
2012 ACCF/AATS/SCAI/STS Expert Consensus Document on Transcatheter Aortic Valve Replacement
Holmes, D. R., Mack, M. J., Kaul, S., Agnihotri, A., Alexander, K. P., Bailey, S. R., Calhoon, J. H., Carabello, B. A., Desai, M. Y., Edwards, F. H., et al. (2012) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2012.01.001 · Cited by 749
Jilaihawi, H., Kashif, M., Fontana, G., Furugen, A., Shiota, T., Friede, G., Makhija, R., Doctor, N., Leon, M. B., & Makkar, R. R. (2012) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2011.11.045 · Cited by 480
Willson, A. B., Webb, J. G., LaBounty, T. M., Achenbach, S., Moss, R., Wheeler, M., Thompson, C., Min, J. K., Gurvitch, R., Norgaard, B. L., et al. (2012) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2011.12.015 · Cited by 407
Transcatheter aortic valve implantation: current and future approaches
Rodés-Cabau, J. (2012) · Nature Reviews Cardiology · doi:10.1038/nrcardio.2011.164 · Cited by 306
Kamat, A. M., Flaig, T. W., Grossman, H. B., Konety, B., Lamm, D., O'Donnell, M. A., Uchio, E., Efstathiou, J. A., & Taylor, J. A. (2015) · Nature Reviews Urology · doi:10.1038/nrurol.2015.58 · Cited by 252
Standardized Imaging for Aortic Annular Sizing
Kasel, A. M., Cassese, S., Bleiziffer, S., Amaki, M., Hahn, R. T., Kastrati, A., & Sengupta, P. P. (2013) · JACC: Cardiovascular Imaging · doi:10.1016/j.jcmg.2012.12.005 · Cited by 240
Sinning, J.-M., Vasa-Nicotera, M., Chin, D., Hammerstingl, C., Ghanem, A., Bence, J., Kovac, J., Grube, E., Nickenig, G., & Werner, N. (2013) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2013.02.088 · Cited by 207
Aortic Annulus Diameter Determination by Multidetector Computed Tomography
Gurvitch, R., Webb, J. G., Yuan, R., Johnson, M., Hague, C., Willson, A. B., Toggweiler, S., Wood, D. A., Ye, J., Moss, R., et al. (2011) · JACC: Cardiovascular Interventions · doi:10.1016/j.jcin.2011.07.014 · Cited by 204
“(11) found that 39% would not be candidates for a oreValve prosthesis (Medtronic Inc.”
BackgroundMethodJabbour, A., Ismail, T. F., Moat, N., Gulati, A., Roussin, I., Alpendurada, F., Park, B., Okoroafor, F., Asgar, A., Barker, S., et al. (2011) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2011.09.010 · Cited by 202
“Cardiovascular magnetic resonance (CMR) and cardiac computed tomography (CCT) allow routine assessment of AV annulus and aortic root morphology in multiple imaging planes, affording assessment of their ellipsoid nature, which may better guide TAVI size selection (8,9).”
BackgroundHolmes, D. R., Mack, M. J., Kaul, S., Agnihotri, A., Alexander, K. P., Bailey, S. R., Calhoon, J. H., Carabello, B. A., Desai, M. Y., Edwards, F. H., et al. (2012) · Catheterization and Cardiovascular Interventions · doi:10.1002/ccd.24351 · Cited by 200
“The valvuloplasty balloon size used is generally 20 mm to 23 mm, depending on the size of the annulus (110,211,212).”
MethodHamdan, A., Guetta, V., Konen, E., Goitein, O., Segev, A., Raanani, E., Spiegelstein, D., Hay, I., Di Segni, E., Eldar, M., et al. (2012) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2011.09.045 · Cited by 195
“as device dislodgment, perivalvular leakage, or annular rupture (10,11).”
BackgroundNuis, R.-J., Van Mieghem, N. M., Schultz, C. J., Tzikas, A., Van der Boon, R. M., Maugenest, A.-M., Cheng, J., Piazza, N., van Domburg, R. T., Serruys, P. W., et al. (2011) · European Heart Journal · doi:10.1093/eurheartj/ehr110 · Cited by 191
“Previous coronary artery bypass graft surgery, n (%) 12 (19) 9 (17) 3 (25) 0.”
BackgroundInfluentialSelf-citationAltiok, E., Koos, R., Schröder, J., Brehmer, K., Hamada, S., Becker, M., Mahnken, A. H., Almalla, M., Dohmen, G., Autschbach, R., et al. (2011) · Heart · doi:10.1136/hrt.2011.223974 · Cited by 190
Tzamtzis, S., Viquerat, J., Yap, J., Mullen, M. J., & Burriesci, G. (2013) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2012.04.009 · Cited by 179
Zahn, R., Gerckens, U., Linke, A., Sievert, H., Kahlert, P., Hambrecht, R., Sack, S., Abdel-Wahab, M., Hoffmann, E., Schiele, R., et al. (2013) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2013.03.024 · Cited by 160
Metadata
- Authors
- Schultz, C. J., Moelker, A., Piazza, N., Tzikas, A., Otten, A., Nuis, R. J., Neefjes, L. A., van Geuns, R. J., de Feyter, P., Krestin, G., Serruys, P. W., & de Jaegere, P. P. T.
- Venue
- European Heart Journal
- Publisher
- Oxford University Press (OUP)
- Published
- 2009-12-07
- Volume
- 31
- Issue
- 7
- Pages
- 849-856
- ISSN
- 0195-668X (ISSN-L)
- 1522-9645
- OpenAlex
- W1987271654
- Cited by
- 183
- References
- 25
- FWCI
- 13.84
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.