Infection after pacemaker implantation: infection rates and risk factors associated with infection in a population-based cohort study of 46299 consecutive patients
Open accessThe DOI matches its Crossref record; 31 of the 31 references it cites were found in a registry or an index.
Abstract
AIMS: Infection is a serious complication of pacemaker (PM) systems. Although the rate of infection has been debated, the figures are largely unknown. We therefore studied the incidence of PM infection and its associated risk factors in the Danish population. METHODS AND RESULTS: Since 1982, all PM implantation and removal procedures performed in Denmark have been prospectively recorded in the Danish Pacemaker Register. All patients (n = 46299) who underwent implantation between 1982 and 2007 were included. The total length of surveillance was 236,888 PM-years. The incidence of infection was calculated according to the total number of PM-years. The incidence of surgical site infection (≤ 365 days after PM implantation) was compared with later infection in first implant and replacement procedures. Multiple-record and multiple-event-per-subject proportional hazards analyses were used to identify the independent risk factors of PM infection. Surgical site infection occurred in 192 cases after first implantation (incidence rate 4.82/1000 PM-years), and in 133 cases after replacement (12.12/1000 PM-years). Infections occurring more than 365 days after the first implantation occurred in 153 cases (1.02/1000 PM-years), and in 118 cases after replacement (3.26/1000 PM-years). Independent factors associated with an increased risk of PM infection were a greater number of PM operations (including replacements), male sex, younger age, implantation during the earliest part of the study period, and absence of antibiotics (P< 0.001). CONCLUSION: The overall risk of infection after PM implantation was low. A greater number of operations augmented the risk of infection. This should be taken into account when considering revisions of PM systems.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Foreign body reaction to biomaterials
Anderson, J. M., Rodriguez, A., & Chang, D. T. (2008) · Seminars in Immunology · doi:10.1016/j.smim.2007.11.004 · Cited by 5,138
Guideline for Prevention of Surgical Site Infection, 1999
Mangram, A. J., Horan, T. C., Pearson, M. L., Silver, L. C., Jarvis, W. R., & The Hospital Infection Control Practices Advisory Committee (1999) · Infection Control & Hospital Epidemiology · doi:10.1086/501620 · Cited by 4,595
Klug, D., Balde, M., Pavin, D., Hidden-Lucet, F., Clementy, J., Sadoul, N., Rey, J. L., Lande, G., Lazarus, A., Victor, J., et al. (2007) · Circulation · doi:10.1161/circulationaha.106.678664 · Cited by 700
The Challenge of Treating Biofilm-associated Bacterial Infections
del Pozo, J. L., & Patel, R. (2007) · Clinical Pharmacology & Therapeutics · doi:10.1038/sj.clpt.6100247 · Cited by 671
Antibiotic-eluting medical devices for various applications
ZILBERMAN, M., & ELSNER, J. (2008) · Journal of Controlled Release · doi:10.1016/j.jconrel.2008.05.020 · Cited by 610
Implant infections: a haven for opportunistic bacteria
Schierholz, J. M., & Beuth, J. (2001) · Journal of Hospital Infection · doi:10.1053/jhin.2001.1052 · Cited by 509
Nonvalvular Cardiovascular Device–Related Infections
Baddour, L. M., Bettmann, M. A., Bolger, A. F., Epstein, A. E., Ferrieri, P., Gerber, M. A., Gewitz, M. H., Jacobs, A. K., Levison, M. E., Newburger, J. W., et al. (2003) · Circulation · doi:10.1161/01.cir.0000093201.57771.47 · Cited by 496
Increasing rates of cardiac device infections among medicare beneficiaries: 1990–1999
Cabell, C. H., Heidenreich, P. A., Chu, V. H., Moore, C. M., Stryjewski, M. E., Corey, G. R., & Fowler, V. G. (2004) · American Heart Journal · doi:10.1016/j.ahj.2003.06.005 · Cited by 397
Permanent Pacemaker and Implantable Cardioverter Defibrillator Infection: A Population-Based Study
Uslan, D. Z. (2007) · Archives of Internal Medicine · doi:10.1001/archinte.167.7.669 · Cited by 391
Rising Rates of Cardiac Rhythm Management Device Infections in the United States: 1996 through 2003
Voigt, A., Shalaby, A., & Saba, S. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2006.05.016 · Cited by 379
Cited by
Tong, S. Y. C., Davis, J. S., Eichenberger, E., Holland, T. L., & Fowler, V. G. (2015) · Clinical Microbiology Reviews · doi:10.1128/cmr.00134-14 · Cited by 5,192
Kusumoto, F. M., Schoenfeld, M. H., Wilkoff, B. L., Berul, C. I., Birgersdotter-Green, U. M., Carrillo, R., Cha, Y.-M., Clancy, J., Deharo, J.-C., Ellenbogen, K. A., et al. (2017) · Heart Rhythm · doi:10.1016/j.hrthm.2017.09.001 · Cited by 1,199
Kirkfeldt, R. E., Johansen, J. B., Nohr, E. A., Jorgensen, O. D., & Nielsen, J. C. (2014) · European Heart Journal · doi:10.1093/eurheartj/eht511 · Cited by 871
Self-citationChallenges in Infective Endocarditis
Cahill, T. J., Baddour, L. M., Habib, G., Hoen, B., Salaun, E., Pettersson, G. B., Schäfers, H. J., & Prendergast, B. D. (2017) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2016.10.066 · Cited by 715
Percutaneous Implantation of an Entirely Intracardiac Leadless Pacemaker
Reddy, V. Y., Exner, D. V., Cantillon, D. J., Doshi, R., Bunch, T. J., Tomassoni, G. F., Friedman, P. A., Estes, N. A. M., Ip, J., Niazi, I., et al. (2015) · New England Journal of Medicine · doi:10.1056/nejmoa1507192 · Cited by 539
Polyzos, K. A., Konstantelias, A. A., & Falagas, M. E. (2015) · EP Europace · doi:10.1093/europace/euv053 · Cited by 493
Biomedical Applications of Titanium Alloys: A Comprehensive Review
Marin, E., & Lanzutti, A. (2023) · Materials · doi:10.3390/ma17010114 · Cited by 489
Blomström-Lundqvist, C., Traykov, V., Erba, P. A., Burri, H., Nielsen, J. C., Bongiorni, M. G., Poole, J., Boriani, G., Costa, R., Deharo, J.-C., et al. (2020) · EP Europace · doi:10.1093/europace/euz246 · Cited by 423
Self-citationSandoe, J. A. T., Barlow, G., Chambers, J. B., Gammage, M., Guleri, A., Howard, P., Olson, E., Perry, J. D., Prendergast, B. D., Spry, M. J., et al. (2015) · Journal of Antimicrobial Chemotherapy · doi:10.1093/jac/dku383 · Cited by 403
Blomström-Lundqvist, C., Traykov, V., Erba, P. A., Burri, H., Nielsen, J. C., Bongiorni, M. G., Poole, J., Boriani, G., Costa, R., Deharo, J.-C., et al. (2020) · European Journal of Cardio-Thoracic Surgery · doi:10.1093/ejcts/ezz296 · Cited by 318
Self-citationLi, X., Li, H., Ma, W., Ning, X., Liang, E., Pang, K., Yao, Y., Hua, W., Zhang, S., & Fan, X. (2019) · Heart Rhythm · doi:10.1016/j.hrthm.2019.04.043 · Cited by 246
Cardiac imaging in infectious endocarditis
Bruun, N. E., Habib, G., Thuny, F., & Sogaard, P. (2014) · European Heart Journal · doi:10.1093/eurheartj/eht274 · Cited by 222
“number of device implantations has increased two- to three-fold across the last 10–15 years.(28,29) Unfortunately, the rate of CDI has increased in parallel.”
BackgroundBlomström-Lundqvist, C., Traykov, V., Erba, P. A., Burri, H., Nielsen, J. C., Bongiorni, M. G., Poole, J., Boriani, G., Costa, R., Deharo, J.-C., et al. (2020) · European Heart Journal · doi:10.1093/eurheartj/ehaa010 · Cited by 222
“12/1000 deviceyears after replacement.(3) The incidence of CIED infection in the USA increased from 1.”
BackgroundSelf-citationAuthors (EHRA Task Force Members), Deharo, J. C., Bongiorni, M. G., Rozkovec, A., Bracke, F., Defaye, P., Fernandez-Lozano, I., Golzio, P. G., Hansky, B., Kennergren, C., et al. (2012) · Europace · doi:10.1093/europace/eur338 · Cited by 210
“True incidence calculated from the number of complications expressed as a proportion of the time of exposure to the risk, in this case lead exposure, has rarely been calculated.(22,23) Local extractions rates will vary on case mix and in-house expertise.”
BackgroundPrutkin, J. M., Reynolds, M. R., Bao, H., Curtis, J. P., Al-Khatib, S. M., Aggarwal, S., & Uslan, D. Z. (2014) · Circulation · doi:10.1161/circulationaha.114.009081 · Cited by 199
“Other studies that have used multivariable models have not included the c-statistic, so direct comparison of model strengths cannot be completed.(19,23,27,29,34,39,40) Regardless, even with a large number of patients and predictive variables, this study suggests that there are important unknown clinical and patient ch…”
MethodRisk Factors for Infections Involving Cardiac Implanted Electronic Devices
Birnie, D. H., Wang, J., Alings, M., Philippon, F., Parkash, R., Manlucu, J., Angaran, P., Rinne, C., Coutu, B., Low, R. A., et al. (2019) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2019.09.060 · Cited by 173
Lin, Y.-S., Hung, S.-P., Chen, P.-R., Yang, C.-H., Wo, H.-T., Chang, P.-C., Wang, C.-C., Chou, C.-C., Wen, M.-S., Chung, C.-M., et al. (2014) · Medicine · doi:10.1097/md.0000000000000213 · Cited by 58
“com/MD/A84), our findings corresponded to a large registered study from Danish.(11) In terms of risk factors of CIED infection, more comprehensive parameters, such as baseline characteristics, the type of procedures, providers and medications, were analyzed in our study when comparison with another nation cohort study…”
ResultInfluential
Metadata
- Authors
- Johansen, J. B., Jorgensen, O. D., Moller, M., Arnsbo, P., Mortensen, P. T., & Nielsen, J. C.
- Venue
- European Heart Journal
- Publisher
- Oxford University Press (OUP)
- Published
- 2011-01-20
- Volume
- 32
- Issue
- 8
- Pages
- 991-998
- ISSN
- 0195-668X (ISSN-L)
- 1522-9645
- OpenAlex
- W2065936757
- Cited by
- 376
- References
- 31
- FWCI
- 14.91
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.