Percutaneous pulmonary valve implantation: two-centre experience with more than 100 patients
The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Abstract
AIMS: Dysfunction of valved conduits in the right ventricular outflow tract (RVOT) limits durability and enforces repeated surgical interventions. We report on our combined two-centre experience with percutaneous pulmonary valve implantation (PPVI). METHODS AND RESULTS: One hundred and two patients with RVOT dysfunction [median weight: 63 kg (54.2-75.9 kg), median age: 21.5 years (16.2-30.1 years), diagnoses: TOF/PA 61, TAC 14, TGA 9, other 10, AoS post-Ross-OP 8] were scheduled for PPVI since December 2006. Percutaneous pulmonary valve implantation was performed in all patients. Pre-stenting of the RVOT was done in 97 patients (95%). The median peak systolic RVOT gradient decreased from 37 mmHg (29-46 mmHg) to 14 mmHg (9-17 mmHg, P < 0.001) and the ratio RV pressure/AoP decreased from 62% (53-76%) to 36% (30-42%, P < 0.0001). The median end-diastolic RV-volume index (MRI) decreased from 106 mL/m(2) (93-133 mL/m(2)) to 90 mL/m(2) (71-108 mL/m(2), P = 0.001). Pulmonary regurgitation was significantly reduced in all patients. One patient died due to compression of the left coronary artery. The incidence of stent fractures was 5 of 102 (5%). During follow-up [median: 352 days (99-390 days)] one percutaneous valve had to be removed surgically 6 months after implantation due to bacterial endocarditis. In 8 of 102 patients, a repeated dilatation of the valve was done due to a significant residual systolic pressure gradient, which resulted in a valve-in-valve procedure in four. CONCLUSION: This study shows that PPVI is feasible and it improves the haemodynamics in a selected patient collective. Apart from one coronary compression, the rate of complications at short-term follow-up was low. Percutaneous pulmonary valve implantation can be performed by experienced interventionalists with similar results as originally published. The intervention is technically challenging and longer clinical follow-up is needed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Gatzoulis, M. A., Balaji, S., Webber, S. A., Siu, S. C., Hokanson, J. S., Poile, C., Rosenthal, M., Nakazawa, M., Moller, J. H., Gillette, P. C., et al. (2000) · The Lancet · doi:10.1016/s0140-6736(00)02714-8 · Cited by 1,779 · cited 1×
“The correlation between QRS duration and RV dilation as a risk factor for sudden death long term after Fallot correction is known for years.(18,19) Today cMRI is the best diagnostic tool to assess ventricular volumes, mass, and function.”
BackgroundImages in Cardiovascular Medicine
(2012) · Wilderness & Environmental Medicine · doi:10.1016/j.wem.2012.05.013 · Cited by 1,519
Bonhoeffer, P., Boudjemline, Y., Saliba, Z., Merckx, J., Aggoun, Y., Bonnet, D., Acar, P., Le Bidois, J., Sidi, D., & Kachaner, J. (2000) · The Lancet · doi:10.1016/s0140-6736(00)02844-0 · Cited by 1,095
Gatzoulis, M. A., Till, J. A., Somerville, J., & Redington, A. N. (1995) · Circulation · doi:10.1161/01.cir.92.2.231 · Cited by 786
Davlouros, P. A., Kilner, P. J., Hornung, T. S., Li, W., Francis, J. M., Moon, J. C. C., Smith, G. C., Tat, T., Pennell, D. J., & Gatzoulis, M. A. (2002) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(02)02566-4 · Cited by 553
Therrien, J., Siu, S. C., McLaughlin, P. R., Liu, P. P., Williams, W. G., & Webb, G. D. (2000) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(00)00930-x · Cited by 543
Lurz, P., Coats, L., Khambadkone, S., Nordmeyer, J., Boudjemline, Y., Schievano, S., Muthurangu, V., Lee, T. Y., Parenzan, G., Derrick, G., et al. (2008) · Circulation · doi:10.1161/circulationaha.107.735779 · Cited by 481
Percutaneous Pulmonary Valve Implantation in Humans: Results in 59 Consecutive Patients
Khambadkone, S., Coats, L., Taylor, A., Boudjemline, Y., Derrick, G., Tsang, V., Cooper, J., Muthurangu, V., Hegde, S. R., Razavi, R. S., et al. (2005) · Circulation · doi:10.1161/circulationaha.104.523266 · Cited by 459
Vliegen, H. W., van Straten, A., de Roos, A., Roest, A. A. W., Schoof, P. H., Zwinderman, A. H., Ottenkamp, J., van der Wall, E. E., & Hazekamp, M. G. (2002) · Circulation · doi:10.1161/01.cir.0000030995.59403.f8 · Cited by 372
Buechel, E. R. V., Dave, H. H., Kellenberger, C. J., Dodge-Khatami, A., Pretre, R., Berger, F., & Bauersfeld, U. (2005) · European Heart Journal · doi:10.1093/eurheartj/ehi581 · Cited by 340
Self-citationPulmonary Valve Replacement in Tetralogy of Fallot: Impact on Survival and Ventricular Tachycardia
Harrild, D. M., Berul, C. I., Cecchin, F., Geva, T., Gauvreau, K., Pigula, F., & Walsh, E. P. (2009) · Circulation · doi:10.1161/circulationaha.108.775221 · Cited by 331
Zahn, E. M., Hellenbrand, W. E., Lock, J. E., & McElhinney, D. B. (2009) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2009.06.034 · Cited by 322
Frigiola, A., Tsang, V., Bull, C., Coats, L., Khambadkone, S., Derrick, G., Mist, B., Walker, F., van Doorn, C., Bonhoeffer, P., et al. (2008) · Circulation · doi:10.1161/circulationaha.107.756825 · Cited by 304
Nordmeyer, J., Khambadkone, S., Coats, L., Schievano, S., Lurz, P., Parenzan, G., Taylor, A. M., Lock, J. E., & Bonhoeffer, P. (2007) · Circulation · doi:10.1161/circulationaha.106.674259 · Cited by 214
The Natural History of Isolated Congenital Pulmonary Valve Incompetence: Surgical Implications
Shimazaki, Y., Blackstone, E., & Kirklin, J. (1984) · The Thoracic and Cardiovascular Surgeon · doi:10.1055/s-2007-1023399 · Cited by 154
Kanter, K. R., Budde, J. M., Parks, W. J., Tam, V. K. H., Sharma, S., Williams, W. H., & Fyfe, D. A. (2002) · The Annals of Thoracic Surgery · doi:10.1016/s0003-4975(02)03568-3 · Cited by 150
Extended Application of Percutaneous Pulmonary Valve Implantation
Momenah, T. S., Oakley, R. M. E., Najashi, K. S. A., Khoshhal, S., Qethamy, H. O. A., & Bonhoeffer, P. (2009) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2008.08.061 · Cited by 142
Nordmeyer, J., Coats, L., Lurz, P. C., Lee, T.-Y., Derrick, G. P., Rees, P. G., Cullen, S., Taylor, A. M., Khambadkone, S., & Bonhoeffer, P. (2008) · European Heart Journal · doi:10.1093/eurheartj/ehn073 · Cited by 113
Singh, G. K., Greenberg, S. B., Yap, Y. S., Delany, D. P., Keeton, B., & Monro, J. (1998) · American Journal of Cardiology · doi:10.1016/s0002-9149(98)00171-4 · Cited by 98
Rescue surgery following percutaneous pulmonary valve implantation☆☆☆
Kostolny, M., Tsang, V. T., Nordmeyer, J., van Doorn, C. A., Frigiola, A., Khambadkone, S., de Leval, M. R., & Bonhoeffer, P. (2008) · European Journal of Cardio-Thoracic Surgery · doi:10.1016/j.ejcts.2007.12.034 · Cited by 71
Nonsurgical pulmonary valve replacement: Why, when, and how?
Khambadkone, S., & Bonhoeffer, P. (2004) · Catheterization and Cardiovascular Interventions · doi:10.1002/ccd.20122 · Cited by 66
Schreiber, C., Eicken, A., Balling, G., Wottke, M., Schumacher, G., Paek, S. U., Meisner, H., Hess, J., & Lange, R. (2000) · European Journal of Cardio-Thoracic Surgery · doi:10.1016/s1010-7940(00)00449-8 · Cited by 38
Self-citation
Cited by
Zoghbi, W. A., Asch, F. M., Bruce, C., Gillam, L. D., Grayburn, P. A., Hahn, R. T., Inglessis, I., Islam, A. M., Lerakis, S., Little, S. H., et al. (2019) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2019.01.003 · Cited by 439
Morray, B. H., McElhinney, D. B., Cheatham, J. P., Zahn, E. M., Berman, D. P., Sullivan, P. M., Lock, J. E., & Jones, T. K. (2013) · Circulation: Cardiovascular Interventions · doi:10.1161/circinterventions.113.000202 · Cited by 237
McElhinney, D. B., Benson, L. N., Eicken, A., Kreutzer, J., Padera, R. F., & Zahn, E. M. (2013) · Circulation: Cardiovascular Interventions · doi:10.1161/circinterventions.112.000087 · Cited by 232
“maximal reduction of RVOT gradient at the time of Melody valve implant will decrease the risk of IE, they do offer a convenient reminder that a limitation of TPV therapy can be residual or recurrent obstruction and that implanters should strive to maximize gradient reduction at the time of TPV implant.(9,11,12,21)”
BackgroundSelf-citationGillespie, M. J., Rome, J. J., Levi, D. S., Williams, R. J., Rhodes, J. F., Cheatham, J. P., Hellenbrand, W. E., Jones, T. K., Vincent, J. A., Zahn, E. M., et al. (2012) · Circulation: Cardiovascular Interventions · doi:10.1161/circinterventions.112.972216 · Cited by 164
“5% to 23%.(4,5,20) The fact that radiographic follow-up was not standardized limits our ability to conclusively assess the overall freedom from stent fracture after Melody valve-in-BPV implant.”
Background
Metadata
- Authors
- Eicken, A., Ewert, P., Hager, A., Peters, B., Fratz, S., Kuehne, T., Busch, R., Hess, J., & Berger, F.
- Venue
- European Heart Journal
- Publisher
- Oxford University Press (OUP)
- Published
- 2011-01-27
- Volume
- 32
- Issue
- 10
- Pages
- 1260-1265
- ISSN
- 0195-668X (ISSN-L)
- 1522-9645
- OpenAlex
- W2158777464
- Cited by
- 296
- References
- 22
- FWCI
- 21.61
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.