The appropriate and justified use of medical radiation in cardiovascular imaging: a position document of the ESC Associations of Cardiovascular Imaging, Percutaneous Cardiovascular Interventions and Electrophysiology
Open accessThe DOI matches its Crossref record; 38 of the 38 references it cites were found in a registry or an index.
Abstract
The benefits of cardiac imaging are immense, and modern medicine requires the extensive and versatile use of a variety of cardiac imaging techniques. Cardiologists are responsible for a large part of the radiation exposures every person gets per year from all medical sources. Therefore, they have a particular responsibility to avoid unjustified and non-optimized use of radiation, but sometimes are imperfectly aware of the radiological dose of the examination they prescribe or practice. This position paper aims to summarize the current knowledge on radiation effective doses (and risks) related to cardiac imaging procedures. We have reviewed the literature on radiation doses, which can range from the equivalent of 1-60 milliSievert (mSv) around a reference dose average of 15 mSv (corresponding to 750 chest X-rays) for a percutaneous coronary intervention, a cardiac radiofrequency ablation, a multidetector coronary angiography, or a myocardial perfusion imaging scintigraphy. We provide a European perspective on the best way to play an active role in implementing into clinical practice the key principle of radiation protection that: 'each patient should get the right imaging exam, at the right time, with the right radiation dose'.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Recommendations of the International Commission on Radiological Protection
(1961) · Postgraduate Medical Journal · doi:10.1136/pgmj.37.425.168-b · Cited by 5,862
The 2007 recommendations of the International Commission on Radiological Protection
Valentin, J. (2007) · Elsevier eBooks · Cited by 4,105
Sources and effects of ionizing radiation
(2018) · United Nations Scientific Committee on the Effects of Atomic Radiation (UNSCEAR) Reports · doi:10.18356/f48d655d-en · Cited by 3,985
Smith-Bindman, R. (2009) · Archives of Internal Medicine · doi:10.1001/archinternmed.2009.427 · Cited by 2,464
Mathews, J. D., Forsythe, A. V., Brady, Z., Butler, M. W., Goergen, S. K., Byrnes, G. B., Giles, G. G., Wallace, A. B., Anderson, P. R., Guiver, T. A., et al. (2013) · BMJ · doi:10.1136/bmj.f2360 · Cited by 2,029
Effective Doses in Radiology and Diagnostic Nuclear Medicine: A Catalog
Mettler, F. A., Huda, W., Yoshizumi, T. T., & Mahesh, M. (2008) · Radiology · doi:10.1148/radiol.2481071451 · Cited by 2,008
Risk of cancer from diagnostic X-rays: estimates for the UK and 14 other countries
de González, A. B., & Darby, S. (2004) · The Lancet · doi:10.1016/s0140-6736(04)15433-0 · Cited by 1,718
Stewart, F. A., Akleyev, A. V., Hauer-Jensen, M., Hendry, J. H., Kleiman, N. J., MacVittie, T. J., Aleman, B. M., Edgar, A. B., Mabuchi, K., Muirhead, C. R., et al. (2012) · Annals of the ICRP · doi:10.1016/j.icrp.2012.02.001 · Cited by 1,604
Benefits and costs, an eternal balance
Dixon, A. K. (2007) · Annals of the ICRP · doi:10.1016/j.icrp.2007.09.001 · Cited by 1,355
Health Risks from Exposure to Low Levels of Ionizing Radiation: BEIR VII Phase 2
(2006) · National Academies Press eBooks · doi:10.17226/11340 · Cited by 904
Mettler, F. A., Bhargavan, M., Faulkner, K., Gilley, D. B., Gray, J. E., Ibbott, G. S., Lipoti, J. A., Mahesh, M., McCrohan, J. L., Stabin, M. G., et al. (2009) · Radiology · doi:10.1148/radiol.2532082010 · Cited by 853
Radiation Dose to Patients From Cardiac Diagnostic Imaging
Einstein, A. J., Moser, K. W., Thompson, R. C., Cerqueira, M. D., & Henzlova, M. J. (2007) · Circulation · doi:10.1161/circulationaha.107.688101 · Cited by 806
Christner, J. A., Kofler, J. M., & McCollough, C. H. (2010) · American Journal of Roentgenology · doi:10.2214/ajr.09.3462 · Cited by 492
Venneri, L., Rossi, F., Botto, N., Andreassi, M. G., Salcone, N., Emad, A., Lazzeri, M., Gori, C., Vano, E., & Picano, E. (2009) · American Heart Journal · doi:10.1016/j.ahj.2008.08.009 · Cited by 360
Self-citationRehani, M. M., Ciraj-Bjelac, O., Vañó, E., Miller, D. L., Walsh, S., Giordano, B. D., & Persliden, J. (2010) · Annals of the ICRP · doi:10.1016/j.icrp.2012.03.001 · Cited by 344
Self-citationACCF Proposed Method for Evaluating the Appropriateness of Cardiovascular Imaging
Patel, M. R., Spertus, J. A., Brindis, R. G., Hendel, R. C., Douglas, P. S., Peterson, E. D., Wolk, M. J., Allen, J. M., & Raskin, I. E. (2005) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2005.08.030 · Cited by 332
Sustainability of medical imaging
Picano, E. (2004) · BMJ · doi:10.1136/bmj.328.7439.578 · Cited by 321
Self-citationRecommendations for reducing radiation exposure in myocardial perfusion imaging
Cerqueira, M. D., Allman, K. C., Ficaro, E. P., Hansen, C. L., Nichols, K. J., Thompson, R. C., Decker, W. A. V., & Yakovlevitch, M. (2010) · Journal of Nuclear Cardiology · doi:10.1007/s12350-010-9244-0 · Cited by 312
Heidbuchel, H., Wittkampf, F. H. M., Vano, E., Ernst, S., Schilling, R., Picano, E., Mont, L., ESC Scientific Document Group, Jais, P., de Bono, J., et al. (2014) · EP Europace · doi:10.1093/europace/eut409 · Cited by 311
Self-citationPatient-Specific Dose and Radiation Risk Estimation in Pediatric Cardiac Catheterization
Bacher, K., Bogaert, E., Lapere, R., De Wolf, D., & Thierens, H. (2005) · Circulation · doi:10.1161/01.cir.0000151098.52656.3a · Cited by 274
Leung, A. N., Bull, T. M., Jaeschke, R., Lockwood, C. J., Boiselle, P. M., Hurwitz, L. M., James, A. H., McCullough, L. B., Menda, Y., Paidas, M. J., et al. (2011) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201108-1575st · Cited by 230
Occupational radiation doses in interventional cardiology: a 15-year follow-up
Vaño, E., Gonzalez, L., Fernandez, J. M., Alfonso, F., & Macaya, C. (2006) · The British Journal of Radiology · doi:10.1259/bjr/26829723 · Cited by 214
Picano, E. (2004) · BMJ · doi:10.1136/bmj.329.7470.849 · Cited by 204
Self-citationSmith, R., Hiatt, H., Berwick, D., & Tavistock Group (1999) · BMJ · doi:10.1136/bmj.318.7178.248 · Cited by 191
Historical Review of Occupational Exposures and Cancer Risks in Medical Radiation Workers
Linet, M. S., Kim, K. P., Miller, D. L., Kleinerman, R. A., Simon, S. L., & de Gonzalez, A. B. (2010) · Radiation Research · doi:10.1667/rr2014.1 · Cited by 190
Einstein, A. J., Weiner, S. D., Bernheim, A., Kulon, M., Bokhari, S., Johnson, L. L., Moses, J. W., & Balter, S. (2010) · JAMA · doi:10.1001/jama.2010.1664 · Cited by 164
The Radiation Issue in Cardiology: the time for action is now
Picano, E., & Vano, E. (2011) · Cardiovascular Ultrasound · doi:10.1186/1476-7120-9-35 · Cited by 158
Self-citationRehani, M. M., Vano, E., Ciraj‐Bjelac, O., & Kleiman, N. J. (2011) · Radiation Protection Dosimetry · doi:10.1093/rpd/ncr299 · Cited by 130
Self-citationRadiation exposure and pregnancy
Shaw, P. M., Duncan, A. A., Vouyouka, A. G., & Ozsvath, K. J. (2010) · Journal of Vascular Surgery · doi:10.1016/j.jvs.2010.05.140 · Cited by 125
Lack of radiological awareness among physicians working in a tertiary-care cardiological centre
Mj, C., Hellies, A., Andreassi, M. G., Ghelarducci, B., & Picano, E. (2005) · International Journal of Cardiology · doi:10.1016/j.ijcard.2004.08.070 · Cited by 107
Self-citationClement, C. H., & Stewart, F. A. (2012) · Medical Entomology and Zoology · Cited by 100
Impact of cardiac magnetic resonance imaging on human lymphocyte DNA integrity
Fiechter, M., Stehli, J., Fuchs, T. A., Dougoud, S., Gaemperli, O., & Kaufmann, P. A. (2013) · European Heart Journal · doi:10.1093/eurheartj/eht184 · Cited by 95
Cumulative patient effective dose in cardiology
Bedetti, G., Botto, N., Andreassi, M. G., Traino, C., Vano, E., & Picano, E. (2008) · British Journal of Radiology · doi:10.1259/bjr/29507259 · Cited by 94
Self-citationLow Quality and Lack of Clarity of Current Informed Consent Forms in Cardiology
Terranova, G., Ferro, M., Carpeggiani, C., Recchia, V., Braga, L., Semelka, R. C., & Picano, E. (2012) · JACC. Cardiovascular imaging · doi:10.1016/j.jcmg.2012.03.007 · Cited by 66
Self-citationGaemperli, O., Saraste, A., & Knuuti, J. M. (2011) · European Heart Journal - Cardiovascular Imaging · doi:10.1093/ejechocard/jer240 · Cited by 59
Self-citationEffective dose conversion factors in paediatric interventional cardiology
Karambatsakidou, A., Sahlgren, B., HANSSON, B., Lidegran, M. K., & Fransson, A. (2009) · British Journal of Radiology · doi:10.1259/bjr/57217783 · Cited by 49
Sidhu, M. K., Coley, B. D., Goske, M. J., Connolly, B. L., Racadio, J. M., Yoshizumi, T. T., Utley, T., & Strauss, K. J. (2009) · Pediatric Radiology · doi:10.1007/s00247-009-1392-5 · Cited by 43
Radiation exposure to patients' skin during cardiac resynchronization therapy
Suzuki, S., Furui, S., Yamakawa, T., Isshiki, T., Watanabe, A., Iino, R., Kidouchi, T., & Nakano, Y. (2009) · EP Europace · doi:10.1093/europace/eup302 · Cited by 19
Cited by
Wanhainen, A., Verzini, F., Van Herzeele, I., Allaire, E., Bown, M., Cohnert, T., Dick, F., van Herwaarden, J., Karkos, C., Koelemay, M., et al. (2019) · European Journal of Vascular and Endovascular Surgery · doi:10.1016/j.ejvs.2018.09.020 · Cited by 2,326
Wanhainen, A., Van Herzeele, I., Bastos Goncalves, F., Bellmunt Montoya, S., Berard, X., Boyle, J. R., D’Oria, M., Prendes, C. F., Karkos, C. D., Kazimierczak, A., et al. (2024) · European Journal of Vascular and Endovascular Surgery · doi:10.1016/j.ejvs.2023.11.002 · Cited by 1,207
Goldstein, S. A., Evangelista, A., Abbara, S., Arai, A., Asch, F. M., Badano, L. P., Bolen, M. A., Connolly, H. M., Cuéllar-Calàbria, H., Czerny, M., et al. (2015) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2014.11.015 · Cited by 641
Self-citationLancellotti, P., Pibarot, P., Chambers, J., Edvardsen, T., Delgado, V., Dulgheru, R., Pepi, M., Cosyns, B., Dweck, M. R., Garbi, M., et al. (2016) · European Heart Journal – Cardiovascular Imaging · doi:10.1093/ehjci/jew025 · Cited by 567
Self-citation2019 HRS/EHRA/APHRS/LAHRS expert consensus statement on catheter ablation of ventricular arrhythmias
Cronin, E. M., Bogun, F. M., Maury, P., Peichl, P., Chen, M., Namboodiri, N., Aguinaga, L., Leite, L. R., Al-Khatib, S. M., Anter, E., et al. (2019) · EP Europace · doi:10.1093/europace/euz132 · Cited by 475
Metadata
- Authors
- Picano, E., Vano, E., Rehani, M. M., Cuocolo, A., Mont, L., Bodi, V., Bar, O., Maccia, C., Pierard, L., Sicari, R., Plein, S., Mahrholdt, H., Lancellotti, P., Knuuti, J., Heidbuchel, H., Di Mario, C., & Badano, L. P.
- Venue
- European Heart Journal
- Publisher
- Oxford University Press (OUP)
- Published
- 2014-01-08
- Volume
- 35
- Issue
- 10
- Pages
- 665-672
- ISSN
- 0195-668X (ISSN-L)
- 1522-9645
- OpenAlex
- W2096764054
- Cited by
- 361
- References
- 38
- FWCI
- 32.95
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.