Everolimus-eluting bioresorbable stent vs. durable polymer everolimus-eluting metallic stent in patients with ST-segment elevation myocardial infarction: results of the randomized ABSORB ST-segment elevation myocardial infarction—TROFI II trial
Open accessThe DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.
Abstract
AIMS: Patients with ST-segment elevation myocardial infarction (STEMI) feature thrombus-rich lesions with large necrotic core, which are usually associated with delayed arterial healing and impaired stent-related outcomes. The use of bioresorbable vascular scaffolds (Absorb) has the potential to overcome these limitations owing to restoration of native vessel lumen and physiology at long term. The purpose of this randomized trial was to compare the arterial healing response at short term, as a surrogate for safety and efficacy, between the Absorb and the metallic everolimus-eluting stent (EES) in patients with STEMI. METHODS AND RESULTS: ABSORB-STEMI TROFI II was a multicentre, single-blind, non-inferiority, randomized controlled trial. Patients with STEMI who underwent primary percutaneous coronary intervention were randomly allocated 1:1 to treatment with the Absorb or EES. The primary endpoint was the 6-month optical frequency domain imaging healing score (HS) based on the presence of uncovered and/or malapposed stent struts and intraluminal filling defects. Main secondary endpoint included the device-oriented composite endpoint (DOCE) according to the Academic Research Consortium definition. Between 06 January 2014 and 21 September 2014, 191 patients (Absorb [n = 95] or EES [n = 96]; mean age 58.6 years old; 17.8% females) were enrolled at eight centres. At 6 months, HS was lower in the Absorb arm when compared with EES arm [1.74 (2.39) vs. 2.80 (4.44); difference (90% CI) -1.06 (-1.96, -0.16); Pnon-inferiority < 0.001]. Device-oriented composite endpoint was also comparably low between groups (1.1% Absorb vs. 0% EES). One case of definite subacute stent thrombosis occurred in the Absorb arm (1.1% vs. 0% EES; P = ns). CONCLUSION: Stenting of culprit lesions with Absorb in the setting of STEMI resulted in a nearly complete arterial healing which was comparable with that of metallic EES at 6 months. These findings provide the basis for further exploration in clinically oriented outcome trials.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Clinical End Points in Coronary Stent Trials: A Case for Standardized Definitions
Cutlip, D. E., Windecker, S., Mehran, R., Boam, A., Cohen, D. J., van Es, G.-A., Gabriel Steg, P., Morel, M.-A., Mauri, L., Vranckx, P., et al. (2007) · Circulation · doi:10.1161/circulationaha.106.685313 · Cited by 5,497
Self-citationKeeley, E. C., Boura, J. A., & Grines, C. L. (2003) · The Lancet · doi:10.1016/s0140-6736(03)12113-7 · Cited by 4,361 · cited 1×
“Reperfusion therapy by means of primary percutaneous coronary intervention (pPCI) is the standard of care treatment of patients with ST-segment elevation myocardial infarction (STEMI).(1) New generation drug-eluting stents (DES) have been shown superior to BMS by reducing the risk of recurrent myocardial infarction, s…”
Method(2014) · European Heart Journal · doi:10.1093/eurheartj/ehu278 · Cited by 4,314
2014 ESC/EACTS Guidelines on myocardial revascularization
Kolh, P., Windecker, S., Alfonso, F., Collet, J.-P., Cremer, J., Falk, V., Filippatos, G., Hamm, C., Head, S. J., Jüni, P., et al. (2014) · European Journal of Cardio-Thoracic Surgery · doi:10.1093/ejcts/ezu366 · Cited by 4,199
Self-citationThygesen, K. A. (2007) · Circulation · Cited by 3,126
Third universal definition of myocardial infarction
Thygesen, K., Alpert, J. S., Jaffe, A. S., Simoons, M. L., Chaitman, B. R., White, H. D., the Writing Group on behalf of the Joint ESC/ACCF/AHA/WHF Task Force for the Universal Definition of Myocardial Infarction, Authors/Task Force Members Chairpersons, Thygesen, K., Alpert, J. S., et al. (2012) · European Heart Journal · doi:10.1093/eurheartj/ehs184 · Cited by 3,058
Self-citationKastrati, A., Mehilli, J., Dirschinger, J., Dotzer, F., Schühlen, H., Neumann, F.-J., Fleckenstein, M., Pfafferott, C., Seyfarth, M., & Schömig, A. (2001) · Circulation · doi:10.1161/01.cir.103.23.2816 · Cited by 938
Comparison of Zotarolimus-Eluting and Everolimus-Eluting Coronary Stents
Serruys, P. W., Silber, S., Garg, S., van Geuns, R. J., Richardt, G., Buszman, P. E., Kelbæk, H., van Boven, A. J., Hofma, S. H., Linke, A., et al. (2010) · New England Journal of Medicine · doi:10.1056/nejmoa1004130 · Cited by 670 · cited 2×
“Secondly, EES is currently the best-in-class DES and has become the reference in the stent comparative trials.(21,28) A comprehensive network meta-analysis involving 51 trials that included a total of 52 158 randomized patients with follow-up duration ≥3 years recently demonstrated that EES was associated with lower r…”
BackgroundMethodSelf-citationNakazawa, G., Finn, A. V., Joner, M., Ladich, E., Kutys, R., Mont, E. K., Gold, H. K., Burke, A. P., Kolodgie, F. D., & Virmani, R. (2008) · Circulation · doi:10.1161/circulationaha.107.762047 · Cited by 611 · cited 1×
“Specifically, mean rate of uncovered stents appeared to be as high as 49% in culprit lesions from STEMI when compared with 9% in stable plaques after first-generation DES implantation.(7) The advent of second-generation DES has improved the arterial healing response.”
BackgroundSerruys, P. W., Chevalier, B., Dudek, D., Cequier, A., Carrié, D., Iniguez, A., Dominici, M., van der Schaaf, R. J., Haude, M., Wasungu, L., et al. (2015) · The Lancet · doi:10.1016/s0140-6736(14)61455-0 · Cited by 564 · cited 6×
“Recent study suggests that Absorb may eventually decrease the incidence of angina during follow-up, by reducing fixed and dynamic restenoses and by improving vasomotor responses.(32) In our trial, .”
BackgroundResultInfluentialSelf-citation
Cited by
2018 ESC/EACTS guidelines on myocardial revascularization
Neumann, F.-J., Sousa-Uva, M., Ahlsson, A., Alfonso, F., Banning, A. P., Benedetto, U., Byrne, R. A., Collet, J.-P., Falk, V., Head, S. J., et al. (2019) · European Heart Journal · doi:10.1093/eurheartj/ehy394 · Cited by 7,167
Self-citation2018 ESC/EACTS Guidelines on myocardial revascularization
Neumann, F.-J., Sousa-Uva, M., Ahlsson, A., Alfonso, F., Banning, A. P., Benedetto, U., Byrne, R. A., Collet, J.-P., Falk, V., Head, S. J., et al. (2019) · EuroIntervention · doi:10.4244/eijy19m01_01 · Cited by 1,259
Self-citation2018 ESC/EACTS Guidelines on myocardial revascularization
Sousa-Uva, M., Neumann, F.-J., Ahlsson, A., Alfonso, F., Banning, A. P., Benedetto, U., Byrne, R. A., Collet, J.-P., Falk, V., Head, S. J., et al. (2019) · European Journal of Cardio-Thoracic Surgery · doi:10.1093/ejcts/ezy289 · Cited by 989
Self-citationCassese, S., Byrne, R. A., Ndrepepa, G., Kufner, S., Wiebe, J., Repp, J., Schunkert, H., Fusaro, M., Kimura, T., & Kastrati, A. (2016) · The Lancet · doi:10.1016/s0140-6736(15)00979-4 · Cited by 369
3-Year Clinical Outcomes With Everolimus-Eluting Bioresorbable Coronary Scaffolds
Kereiakes, D. J., Ellis, S. G., Metzger, C., Caputo, R. P., Rizik, D. G., Teirstein, P. S., Litt, M. R., Kini, A., Kabour, A., Marx, S. O., et al. (2017) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2017.10.010 · Cited by 269
Stone, G. W., Gao, R., Kimura, T., Kereiakes, D. J., Ellis, S. G., Onuma, Y., Cheong, W.-F., Jones-McMeans, J., Su, X., Zhang, Z., et al. (2016) · The Lancet · doi:10.1016/s0140-6736(15)01039-9 · Cited by 266
Self-citation2020 Clinical practice guidelines for Stable coronary artery disease
Russian Society of Cardiology (RSC) (2020) · Russian Journal of Cardiology · doi:10.15829/1560-4071-2020-4076 · Cited by 242
“) Таким образом, СЛП***, должны применяться у всех пациентов с ИБС [184-187].”
Paclitaxel-Coated Balloon Angioplasty Versus Drug-Eluting Stent in Acute Myocardial Infarction
Vos, N. S., Fagel, N. D., Amoroso, G., Herrman, J.-P. R., Patterson, M. S., Piers, L. H., van der Schaaf, R. J., Slagboom, T., & Vink, M. A. (2019) · JACC: Cardiovascular Interventions · doi:10.1016/j.jcin.2019.04.016 · Cited by 235
Fully bioresorbable vascular scaffolds: lessons learned and future directions
Jinnouchi, H., Torii, S., Sakamoto, A., Kolodgie, F. D., Virmani, R., & Finn, A. V. (2019) · Nature Reviews Cardiology · doi:10.1038/s41569-018-0124-7 · Cited by 228
Ali, Z. A., Serruys, P. W., Kimura, T., Gao, R., Ellis, S. G., Kereiakes, D. J., Onuma, Y., Simonton, C., Zhang, Z., & Stone, G. W. (2017) · The Lancet · doi:10.1016/s0140-6736(17)31470-8 · Cited by 204
Self-citationAli, Z. A., Gao, R., Kimura, T., Onuma, Y., Kereiakes, D. J., Ellis, S. G., Chevalier, B., Vu, M.-T., Zhang, Z., Simonton, C. A., et al. (2018) · Circulation · doi:10.1161/circulationaha.117.031843 · Cited by 189
Self-citationBioresorbable Scaffold: The Emerging Reality and Future Directions
Sotomi, Y., Onuma, Y., Collet, C., Tenekecioglu, E., Virmani, R., Kleiman, N. S., & Serruys, P. W. (2017) · Circulation Research · doi:10.1161/circresaha.117.310275 · Cited by 162
Self-citationZhang, X.-L., Zhu, L., Wei, Z.-H., Zhu, Q.-Q., Qiao, J.-Z., Dai, Q., Huang, W., Li, X.-H., Xie, J., Kang, L.-N., et al. (2016) · Annals of Internal Medicine · doi:10.7326/m16-0006 · Cited by 31
Metadata
- Authors
- Sabaté, M., Windecker, S., Iñiguez, A., Okkels-Jensen, L., Cequier, A., Brugaletta, S., Hofma, S. H., Räber, L., Christiansen, E. H., Suttorp, M., Pilgrim, T., Anne van Es, G., Sotomi, Y., García-García, H. M., Onuma, Y., & Serruys, P. W.
- Venue
- European Heart Journal
- Publisher
- Oxford University Press (OUP)
- Published
- 2015-09-23
- Volume
- 37
- Issue
- 3
- Pages
- 229-240
- ISSN
- 0195-668X (ISSN-L)
- 1522-9645
- OpenAlex
- W2259115522
- Cited by
- 218
- References
- 27
- FWCI
- 44.54
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.