Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 599

The DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.

Duration of device-detected subclinical atrial fibrillation and occurrence of stroke in ASSERT

Open access
Van Gelder, Isabelle C., Healey, Jeff S., Crijns, Harry J.G.M., Wang, Jia, Hohnloser, Stefan H., Gold, Michael R., Capucci, Alessandro, Lau, Chu-Pak, Morillo, Carlos A., Hobbelt, Anne H., Rienstra, Michiel, Connolly, Stuart J.·2017·European Heart Journal

Abstract

Background: ASSERT demonstrated that subclinical atrial fibrillation (SCAF) is common in pacemaker patients without prior AF and is associated with increased risk of ischemic stroke or systemic embolism. SCAF episodes vary in duration and little is known about the incidence of different durations of SCAF, or their prognosis. Methods and results: ASSERT followed 2580 patients receiving a pacemaker or ICD, aged >65 years with hypertension, without prior AF. The effect of SCAF duration on subsequent risk of ischemic stroke or embolism was evaluated with time-dependent covariate Cox models. Patients in whom the longest SCAF was ≤6 min were excluded from the analysis (n=125). Among 2455 patients during mean follow-up of 2.5 years, the longest single episode of SCAF lasted >6 min to 6 h in 462 patients (18.8%), >6–24 h in 169 (6.9%), and >24 h in 262 (10.7%). SCAF duration >24 h was associated with a significant increased risk of subsequent stroke or systemic embolism (adjusted hazard ratio [HR] 3.24, 95% confidence interval [CI] 1.51–6.95, P=0.003). The risk of ischemic stroke or systemic embolism in patients with SCAF between 6 min and 24 h was not significantly different from patients without SCAF. Conclusions: SCAF >24 h is associated with an increased risk of ischemic stroke or systemic embolism.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/eurheartj/ehx042

Cites

32 of 32 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 32 references

Cited by

See all 599

Metadata

Authors
Van Gelder, I. C., Healey, J. S., Crijns, H. J. G. M., Wang, J., Hohnloser, S. H., Gold, M. R., Capucci, A., Lau, C.-P., Morillo, C. A., Hobbelt, A. H., Rienstra, M., & Connolly, S. J.
Venue
European Heart Journal
Published
2017-03-01
Volume
38
Issue
17
Pages
1339-1344
ISSN
  • 0195-668X (ISSN-L)
  • 1522-9645
OpenAlex
W2598361327
Cited by
599
References
32
FWCI
43.85
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Duration of device-detected subclinical atrial fibrillation and occurrence of stroke in ASSERT. https://app.cochat.ai/papers/10.1093/eurheartj/ehx042
The paper
Van Gelder, I. C., Healey, J. S., Crijns, H. J. G. M., Wang, J., Hohnloser, S. H., Gold, M. R., Capucci, A., Lau, C.-P., Morillo, C. A., Hobbelt, A. H., Rienstra, M., & Connolly, S. J. (2017). Duration of device-detected subclinical atrial fibrillation and occurrence of stroke in ASSERT. European Heart Journal. https://doi.org/10.1093/eurheartj/ehx042

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.