Duration of device-detected subclinical atrial fibrillation and occurrence of stroke in ASSERT
Open accessThe DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.
Abstract
Background: ASSERT demonstrated that subclinical atrial fibrillation (SCAF) is common in pacemaker patients without prior AF and is associated with increased risk of ischemic stroke or systemic embolism. SCAF episodes vary in duration and little is known about the incidence of different durations of SCAF, or their prognosis. Methods and results: ASSERT followed 2580 patients receiving a pacemaker or ICD, aged >65 years with hypertension, without prior AF. The effect of SCAF duration on subsequent risk of ischemic stroke or embolism was evaluated with time-dependent covariate Cox models. Patients in whom the longest SCAF was ≤6 min were excluded from the analysis (n=125). Among 2455 patients during mean follow-up of 2.5 years, the longest single episode of SCAF lasted >6 min to 6 h in 462 patients (18.8%), >6–24 h in 169 (6.9%), and >24 h in 262 (10.7%). SCAF duration >24 h was associated with a significant increased risk of subsequent stroke or systemic embolism (adjusted hazard ratio [HR] 3.24, 95% confidence interval [CI] 1.51–6.95, P=0.003). The risk of ischemic stroke or systemic embolism in patients with SCAF between 6 min and 24 h was not significantly different from patients without SCAF. Conclusions: SCAF >24 h is associated with an increased risk of ischemic stroke or systemic embolism.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Retrieved data provide an insight into the natural history and associated sequelae (Healey 2012, Kaplan 2019, Van Gelder 2017, Varma 2005).63,69,74,75”
From 2021 ISHNE/HRS/EHRA/APHRS Expert Collaborative Statement on mHealth in Arrhythmia Management: Digital Medical Tools for Heart Rhythm Professionals: From the International Society for Holter and Noninvasive Electrocardiology/Heart Rhythm Society/European Heart Rhythm Association/Asia-Pacific Heart Rhythm Society (2021) · cites this paper as Van Gelder 2017
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
2016 ESC Guidelines for the management of atrial fibrillation developed in collaboration with EACTS
Kirchhof, P., Benussi, S., Kotecha, D., Ahlsson, A., Atar, D., Casadei, B., Castella, M., Diener, H.-C., Heidbuchel, H., Hendriks, J., et al. (2016) · European Heart Journal · doi:10.1093/eurheartj/ehw210 · Cited by 6,418
Self-citationSubclinical atrial fibrillation and the risk of stroke
Healey, J. S., Connolly, S. J., Gold, M. R., Israel, C. W., Van Gelder, I. C., Capucci, A., Lau, C. P., Fain, E., Yang, S., Bailleul, C., et al. (2012) · New England Journal of Medicine · doi:10.1056/nejmoa1105575 · Cited by 2,100
(1994) · Archives of Internal Medicine · doi:10.1001/archinte.1994.00420130036007 · Cited by 2,071
Glotzer, T. V., Daoud, E. G., Wyse, D. G., Singer, D. E., Ezekowitz, M. D., Hilker, C., Miller, C., Qi, D., & Ziegler, P. D. (2009) · Circulation: Arrhythmia and Electrophysiology · doi:10.1161/circep.109.849638 · Cited by 879
Glotzer, T. V., Hellkamp, A. S., Zimmerman, J., Sweeney, M. O., Yee, R., Marinchak, R., Cook, J., Paraschos, A., Love, J., Radoslovich, G., et al. (2003) · Circulation · doi:10.1161/01.cir.0000057981.70380.45 · Cited by 750
Progression From Paroxysmal to Persistent Atrial Fibrillation
de Vos, C. B., Pisters, R., Nieuwlaat, R., Prins, M. H., Tieleman, R. G., Coelen, R.-J. S., van den Heijkant, A. C., Allessie, M. A., & Crijns, H. J. G. M. (2010) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2009.11.040 · Cited by 720
Self-citationTemporal relationship between subclinical atrial fibrillation and embolic events
Brambatti, M., Connolly, S. J., Gold, M. R., Morillo, C. A., Capucci, A., Muto, C., Lau, C. P., Van Gelder, I. C., Hohnloser, S. H., Carlson, M., et al. (2014) · Circulation · doi:10.1161/circulationaha.113.007825 · Cited by 676
Lévy, S., Maarek, M., Coumel, P., Guize, L., Lekieffre, J., Medvedowsky, J.-L., & Sebaoun, A. (1999) · Circulation · doi:10.1161/01.cir.99.23.3028 · Cited by 579
Landmark Analysis at the 25-Year Landmark Point
Dafni, U. (2011) · Circulation: Cardiovascular Quality and Outcomes · doi:10.1161/circoutcomes.110.957951 · Cited by 569
Capucci, A., Santini, M., Padeletti, L., Gulizia, M., Botto, G., Boriani, G., Ricci, R., Favale, S., Zolezzi, F., Di Belardino, N., et al. (2005) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2005.07.044 · Cited by 401
Self-citation
Cited by
Hindricks, G., Potpara, T., Dagres, N., Arbelo, E., Bax, J. J., Blomström-Lundqvist, C., Boriani, G., Castella, M., Dan, G.-A., Dilaveris, P. E., et al. (2021) · European Heart Journal · doi:10.1093/eurheartj/ehaa612 · Cited by 9,971
Self-citationVan Gelder, I. C., Rienstra, M., Bunting, K. V., Casado-Arroyo, R., Caso, V., Crijns, H. J. G. M., De Potter, T. J. R., Dwight, J., Guasti, L., Hanke, T., et al. (2024) · European Heart Journal · doi:10.1093/eurheartj/ehae176 · Cited by 3,024
Self-citationJoglar, J. A., Chung, M. K., Armbruster, A. L., Benjamin, E. J., Chyou, J. Y., Cronin, E. M., Deswal, A., Eckhardt, L. L., Goldberger, Z. D., Gopinathannair, R., et al. (2024) · Circulation · doi:10.1161/cir.0000000000001193 · Cited by 2,765
Ommen, S. R., Mital, S., Burke, M. A., Day, S. M., Deswal, A., Elliott, P., Evanovich, L. L., Hung, J., Joglar, J. A., Kantor, P., et al. (2020) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2020.08.044 · Cited by 994
Antithrombotic Therapy for Atrial Fibrillation
Lip, G. Y. H., Banerjee, A., Boriani, G., Chiang, C. E., Fargo, R., Freedman, B., Lane, D. A., Ruff, C. T., Turakhia, M., Werring, D., et al. (2018) · Chest · doi:10.1016/j.chest.2018.07.040 · Cited by 939
2023 ACC/AHA/ACCP/HRS Guideline for the Diagnosis and Management of Atrial Fibrillation
Joglar, J. A., Chung, M. K., Armbruster, A. L., Benjamin, E. J., Chyou, J. Y., Cronin, E. M., Deswal, A., Eckhardt, L. L., Goldberger, Z. D., Gopinathannair, R., et al. (2024) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2023.08.017 · Cited by 933
Ommen, S. R., Ho, C. Y., Asif, I. M., Balaji, S., Burke, M. A., Day, S. M., Dearani, J. A., Epps, K. C., Evanovich, L., Ferrari, V. A., et al. (2024) · Circulation · doi:10.1161/cir.0000000000001250 · Cited by 807
2020 AHA/ACC Guideline for the Diagnosis and Treatment of Patients With Hypertrophic Cardiomyopathy
Ommen, S. R., Mital, S., Burke, M. A., Day, S. M., Deswal, A., Elliott, P., Evanovich, L. L., Hung, J., Joglar, J. A., Kantor, P., et al. (2020) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2020.08.045 · Cited by 643
Tzeis, S., Gerstenfeld, E. P., Kalman, J., Saad, E. B., Sepehri Shamloo, A., Andrade, J. G., Barbhaiya, C. R., Baykaner, T., Boveda, S., Calkins, H., et al. (2024) · Europace · doi:10.1093/europace/euae043 · Cited by 634
Writing Committee Members, Ommen, S. R., Mital, S., Burke, M. A., Day, S. M., Deswal, A., Elliott, P., Evanovich, L. L., Hung, J., Joglar, J. A., et al. (2020) · Circulation · doi:10.1161/cir.0000000000000937 · Cited by 605
Andrade, J. G., Aguilar, M., Atzema, C., Bell, A., Cairns, J. A., Cheung, C. C., Cox, J. L., Dorian, P., Gladstone, D. J., Healey, J. S., et al. (2020) · Canadian Journal of Cardiology · doi:10.1016/j.cjca.2020.09.001 · Cited by 562
Self-citationSvendsen, J. H., Diederichsen, S. Z., Højberg, S., Krieger, D. W., Graff, C., Kronborg, C., Olesen, M. S., Nielsen, J. B., Holst, A. G., Brandes, A., et al. (2021) · The Lancet · doi:10.1016/s0140-6736(21)01698-6 · Cited by 550
Steinhubl, S. R., Waalen, J., Edwards, A. M., Ariniello, L. M., Mehta, R. R., Ebner, G. S., Carter, C., Baca-Motes, K., Felicione, E., Sarich, T., et al. (2018) · JAMA · doi:10.1001/jama.2018.8102 · Cited by 539
Screening for Atrial Fibrillation: A Report of the AF-SCREEN International Collaboration
Freedman, B., Camm, J., Calkins, H., Healey, J. S., Rosenqvist, M., Wang, J., Albert, C. M., Anderson, C. S., Antoniou, S., Benjamin, E. J., et al. (2017) · Circulation · doi:10.1161/circulationaha.116.026693 · Cited by 537
Self-citationChen, L. Y., Chung, M. K., Allen, L. A., Ezekowitz, M., Furie, K. L., McCabe, P., Noseworthy, P. A., Perez, M. V., & Turakhia, M. P. (2018) · Circulation · doi:10.1161/cir.0000000000000568 · Cited by 439
2024 AHA/ACC/AMSSM/HRS/PACES/SCMR Guideline for the Management of Hypertrophic Cardiomyopathy
Ommen, S. R., Ho, C. Y., Asif, I. M., Balaji, S., Burke, M. A., Day, S. M., Dearani, J. A., Epps, K. C., Evanovich, L., Ferrari, V. A., et al. (2024) · JACC · doi:10.1016/j.jacc.2024.02.014 · Cited by 382
Lubitz, S. A., Faranesh, A. Z., Selvaggi, C., Atlas, S. J., McManus, D. D., Singer, D. E., Pagoto, S., McConnell, M. V., Pantelopoulos, A., & Foulkes, A. S. (2022) · Circulation · doi:10.1161/circulationaha.122.060291 · Cited by 355
Writing Committee Members, Ommen, S. R., Mital, S., Burke, M. A., Day, S. M., Deswal, A., Elliott, P., Evanovich, L. L., Hung, J., Joglar, J. A., et al. (2020) · Circulation · doi:10.1161/cir.0000000000000938 · Cited by 336
Rienstra, M., Hobbelt, A. H., Alings, M., Tijssen, J. G. P., Smit, M. D., Brügemann, J., Geelhoed, B., Tieleman, R. G., Hillege, H. L., Tukkie, R., et al. (2018) · European Heart Journal · doi:10.1093/eurheartj/ehx739 · Cited by 313
“Atrial fibrillation (AF), especially in combination with heart failure (HF), is associated with cardiovascular morbidity and mortality, with an increasing risk as AF progresses.(1,2) Maintenance of sinus rhythm marks an improved prognosis.”
BackgroundSelf-citationTzeis, S., Gerstenfeld, E. P., Kalman, J., Saad, E. B., Shamloo, A. S., Andrade, J. G., Barbhaiya, C. R., Baykaner, T., Boveda, S., Calkins, H., et al. (2024) · Heart Rhythm · doi:10.1016/j.hrthm.2024.03.017 · Cited by 298
Go, A. S., Reynolds, K., Yang, J., Gupta, N., Lenane, J., Sung, S. H., Harrison, T. N., Liu, T. I., & Solomon, M. D. (2018) · JAMA Cardiology · doi:10.1001/jamacardio.2018.1176 · Cited by 286
Stroke Risk as a Function of Atrial Fibrillation Duration and CHA 2 DS 2 -VASc Score
Kaplan, R. M., Koehler, J., Ziegler, P. D., Sarkar, S., Zweibel, S., & Passman, R. S. (2019) · Circulation · doi:10.1161/circulationaha.119.041303 · Cited by 284
Reiffel, J. A., Verma, A., Kowey, P. R., Halperin, J. L., Gersh, B. J., Wachter, R., Pouliot, E., Ziegler, P. D., & for the REVEAL AF Investigators (2017) · JAMA Cardiology · doi:10.1001/jamacardio.2017.3180 · Cited by 265
Mairesse, G. H., Moran, P., Van Gelder, I. C., Elsner, C., Rosenqvist, M., Mant, J., Banerjee, A., Gorenek, B., Brachmann, J., Varma, N., et al. (2017) · EP Europace · doi:10.1093/europace/eux177 · Cited by 250
“Moreover, the brief episodes of silent AF detected by CIED were recently shown to have a lower than expected stroke incidence rate, and do not seem to have the same significance as more prolonged episodes.(21) Asymptomatic or clinically silent atrial fibrillation Asymptomatic or clinically silent AF is common and pati…”
BackgroundSelf-citationGorenek, B., Bax, J., Boriani, G., Chen, S.-A., Dagres, N., Glotzer, T. V., Healey, J. S., Israel, C. W., Kudaiberdieva, G., Levin, L.-Å., et al. (2017) · EP Europace · doi:10.1093/europace/eux163 · Cited by 247
“Recent results of ASSERT trial, demonstrated that only episodes longer than 24 h of duration were associated with three-fold increase in stroke rate as compared to episodes of shorter duration.(115) Also, the number of AHRE episodes per day—as well as AF burden (whether quantified by duration or number of AHRE)—can va…”
ResultSelf-citationSchnabel, R. B., Haeusler, K. G., Healey, J. S., Freedman, B., Boriani, G., Brachmann, J., Brandes, A., Bustamante, A., Casadei, B., Crijns, H. J. G. M., et al. (2019) · Circulation · doi:10.1161/circulationaha.119.040267 · Cited by 246
Self-citationSmartwatch Performance for the Detection and Quantification of Atrial Fibrillation
Wasserlauf, J., You, C., Patel, R., Valys, A., Albert, D., & Passman, R. (2019) · Circulation: Arrhythmia and Electrophysiology · doi:10.1161/circep.118.006834 · Cited by 245
Palaniappan, L. P., Allen, N. B., Almarzooq, Z. I., Anderson, C. A. M., Arora, P., Avery, C. L., Baker-Smith, C. M., Bansal, N., Currie, M. E., Earlie, R. S., et al. (2026) · Circulation · doi:10.1161/cir.0000000000001412 · Cited by 242
Krittanawong, C., Rogers, A. J., Johnson, K. W., Wang, Z., Turakhia, M. P., Halperin, J. L., & Narayan, S. M. (2021) · Nature Reviews Cardiology · doi:10.1038/s41569-020-00445-9 · Cited by 234
Andrade, J. G., Verma, A., Mitchell, L. B., Parkash, R., Leblanc, K., Atzema, C., Healey, J. S., Bell, A., Cairns, J., Connolly, S., et al. (2018) · Canadian Journal of Cardiology · doi:10.1016/j.cjca.2018.08.026 · Cited by 233
Self-citationKirchhof, P., Blank, B. F., Calvert, M., Camm, A. J., Chlouverakis, G., Diener, H.-C., Goette, A., Huening, A., Lip, G. Y. H., Simantirakis, E., et al. (2017) · American Heart Journal · doi:10.1016/j.ahj.2017.04.015 · Cited by 227
“Other analyses in smaller populations have suggested that longer AHRE episodes (eg, those lasting N24 hours) are associated with a higher stroke risk.(32,33) Furthermore, automated detection algorithms of AHRE by implanted devices have a good sensitivity, but their specificity may not be optimal, especially for short…”
BackgroundHealey, J. S., Gladstone, D. J., Swaminathan, B., Eckstein, J., Mundl, H., Epstein, A. E., Haeusler, K. G., Mikulik, R., Kasner, S. E., Toni, D., et al. (2019) · JAMA Neurology · doi:10.1001/jamaneurol.2019.0617 · Cited by 207
“Median (interquartile range) daily PAC frequency was 48 (13-222) among 2269 patients (31.”
BackgroundSelf-citationAtrial Fibrillation Burden and Clinical Outcomes in Heart Failure
Brachmann, J., Sohns, C., Andresen, D., Siebels, J., Sehner, S., Boersma, L., Merkely, B., Pokushalov, E., Sanders, P., Schunkert, H., et al. (2021) · JACC: Clinical Electrophysiology · doi:10.1016/j.jacep.2020.11.021 · Cited by 202
Screening for Atrial Fibrillation in the Older Population: A Randomized Clinical Trial
Gladstone, D. J., Wachter, R., Schmalstieg-Bahr, K., Quinn, F. R., Hummers, E., Ivers, N., Marsden, T., Thornton, A., Djuric, A., Suerbaum, J., et al. (2021) · JAMA Cardiology · doi:10.1001/jamacardio.2021.0038 · Cited by 195
Self-citationScreening for atrial fibrillation: a call for evidence
Jones, N. R., Taylor, C. J., Hobbs, F. D. R., Bowman, L., & Casadei, B. (2020) · European Heart Journal · doi:10.1093/eurheartj/ehz834 · Cited by 178
The future of atrial fibrillation management: integrated care and stratified therapy
Kirchhof, P. (2017) · The Lancet · doi:10.1016/s0140-6736(17)31072-3 · Cited by 177
Noseworthy, P. A., Kaufman, E. S., Chen, L. Y., Chung, M. K., Elkind, M. S. V., Joglar, J. A., Leal, M. A., McCabe, P. J., Pokorney, S. D., Yao, X., et al. (2019) · Circulation · doi:10.1161/cir.0000000000000740 · Cited by 171
Atrial fibrillation and stroke prevention: 25 years of research at EP Europace journal
Lip, G. Y. H., Proietti, M., Potpara, T., Mansour, M., Savelieva, I., Tse, H. F., Goette, A., Camm, A. J., Blomstrom-Lundqvist, C., Gupta, D., et al. (2023) · Europace · doi:10.1093/europace/euad226 · Cited by 164
Wearables in cardiology: Here to stay
Dagher, L., Shi, H., Zhao, Y., & Marrouche, N. F. (2020) · Heart Rhythm · doi:10.1016/j.hrthm.2020.02.023 · Cited by 107
Varma, N., Cygankiewicz, I., Turakhia, M. P., Heidbuchel, H., Hu, Y.-F., Chen, L. Y., Couderc, J.-P., Cronin, E. M., Estep, J. D., Grieten, L., et al. (2021) · Circulation: Arrhythmia and Electrophysiology · doi:10.1161/circep.120.009204 · Cited by 74
Newer technologies for detection of atrial fibrillation
Zungsontiporn, N., & Link, M. S. (2018) · BMJ · doi:10.1136/bmj.k3946 · Cited by 53
Eerikäinen, L. M., Bonomi, A. G., Dekker, L. R. C., Vullings, R., & Aarts, R. M. (2020) · Cardiovascular Digital Health Journal · doi:10.1016/j.cvdhj.2020.03.001 · Cited by 24
“The relationship between stroke risk and duration of device-detected AF has been studied with implantable devices, with varying results.(47,48) Therefore, insight on stroke risk related to AF detected with wrist-worn wearables is important in order to determine the value of the technology both for maintaining people h…”
Background
Metadata
- Authors
- Van Gelder, I. C., Healey, J. S., Crijns, H. J. G. M., Wang, J., Hohnloser, S. H., Gold, M. R., Capucci, A., Lau, C.-P., Morillo, C. A., Hobbelt, A. H., Rienstra, M., & Connolly, S. J.
- Venue
- European Heart Journal
- Publisher
- Oxford University Press (OUP)
- Published
- 2017-03-01
- Volume
- 38
- Issue
- 17
- Pages
- 1339-1344
- ISSN
- 0195-668X (ISSN-L)
- 1522-9645
- OpenAlex
- W2598361327
- Cited by
- 599
- References
- 32
- FWCI
- 43.85
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.