CoChat

Nurse-led vs. usual-care for atrial fibrillation

Open access
Wijtvliet, E P J Petra, Tieleman, Robert G, van Gelder, Isabelle C, Pluymaekers, Nikki A H A, Rienstra, Michiel, Folkeringa, Richard J, Bronzwaer, Patrick, Elvan, Arif, Elders, Jan, Tukkie, Raymond, Luermans, Justin G L M, Van Asselt, A D I Thea, Van Kuijk, Sander M J, Tijssen, Jan G, Crijns, Harry J G M, RACE 4 Investigators · 2020 · European Heart Journal
Cited by 115

The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.

Abstract

Background: Nurse-led integrated care is expected to improve outcome of patients with atrial fibrillation compared with usual-care provided by a medical specialist. Methods and results: We randomized 1375 patients with atrial fibrillation (64 ± 10 years, 44% women, 57% had CHA2DS2-VASc ≥ 2) to receive nurse-led care or usual-care. Nurse-led care was provided by specialized nurses using a decision-support tool, in consultation with the cardiologist. The primary endpoint was a composite of cardiovascular death and cardiovascular hospital admissions. Of 671 nurse-led care patients, 543 (81%) received anticoagulation in full accordance with the guidelines against 559 of 683 (82%) usual-care patients. The cumulative adherence to guidelines-based recommendations was 61% under nurse-led care and 26% under usual-care. Over 37 months of follow-up, the primary endpoint occurred in 164 of 671 patients (9.7% per year) under nurse-led care and in 192 of 683 patients (11.6% per year) under usual-care [hazard ratio (HR) 0.85, 95% confidence interval (CI) 0.69 to 1.04, P = 0.12]. There were 124 vs. 161 hospitalizations for arrhythmia events (7.0% and 9.4% per year), and 14 vs. 22 for heart failure (0.7% and 1.1% per year), respectively. Results were not consistent in a pre-specified subgroup analysis by centre experience, with a HR of 0.52 (95% CI 0.37–to 0.71) in four experienced centres and of 1.24 (95% CI 0.94–1.63) in four less experienced centres (P for interaction <0.001). Conclusion: Our trial failed to show that nurse-led care was superior to usual-care. The data suggest that nurse-led care by an experienced team could be clinically beneficial (ClinicalTrials.gov NCT01740037). Trial Registration number: ClinicalTrials.gov (NCT01740037).

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/eurheartj/ehz666

Cites

10 of 10 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 10 references

Cited by

See all 115

Metadata

Authors
Wijtvliet, E. P. J. P., Tieleman, R. G., van Gelder, I. C., Pluymaekers, N. A. H. A., Rienstra, M., Folkeringa, R. J., Bronzwaer, P., Elvan, A., Elders, J., Tukkie, R., Luermans, J. G. L. M., Van Asselt, A. D. I. T., Van Kuijk, S. M. J., Tijssen, J. G., Crijns, H. J. G. M., & RACE 4 Investigators
Venue
European Heart Journal
Published
2019-09-23
Volume
41
Issue
5
Pages
634-641
ISSN
  • 0195-668X (ISSN-L)
  • 1522-9645
OpenAlex
W2975599560
Cited by
115
References
10
FWCI
8.64
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Nurse-led vs. usual-care for atrial fibrillation. https://app.cochat.ai/papers/10.1093/eurheartj/ehz666
The paper
Wijtvliet, E. P. J. P., Tieleman, R. G., van Gelder, I. C., Pluymaekers, N. A. H. A., Rienstra, M., Folkeringa, R. J., Bronzwaer, P., Elvan, A., Elders, J., Tukkie, R., Luermans, J. G. L. M., Van Asselt, A. D. I. T., Van Kuijk, S. M. J., Tijssen, J. G., Crijns, H. J. G. M., & RACE 4 Investigators. (2020). Nurse-led vs. usual-care for atrial fibrillation. European Heart Journal. https://doi.org/10.1093/eurheartj/ehz666

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.