Pre-implantation implantable cardioverter defibrillator concerns and Type D personality increase the risk of mortality in patients with an implantable cardioverter defibrillator
Open accessThe DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Abstract
AIMS: Little is known about the influence of psychological factors on prognosis in implantable cardioverter defibrillator (ICD) patients. We examined the influence of the distressed personality (Type D) and pre-implantation device concerns on short-term mortality in ICD patients. METHODS AND RESULTS: Consecutively implanted ICD patients (N = 371; 79.5% men) completed the Type D Scale and the ICD Patient Concerns questionnaire prior to implantation and were followed up for short-term mortality. The prevalence of Type D was 22.4%, whereas 34.2% had high levels of ICD concerns. The incidence of mortality was higher in Type D vs. non-Type D patients [13.3% vs. 4.92%; hazard ratio (HR): 2.74; 95% confidence interval (CI): 1.24-6.03] and in patients with high vs. low levels of ICD concerns (11.0% vs. 4.5%; HR: 2.38; 95% CI: 1.08-5.23). Type D personality (HR: 2.79; 95% CI: 1.25-6.21) and high levels of ICD concerns (HR: 2.38; 95% CI: 1.06-5.34) remained independent predictors of mortality in separate analyses, adjusting for sex, age, ICD indication, coronary artery disease, and shocks. Patients with clustering of both Type D personality and high levels of pre-implantation concerns (HR: 3.86; 95% CI: 1.64-9.10) had a poorer survival compared with patients with one or none of these risk markers in adjusted analysis. Shocks during the follow-up period were also associated with mortality (HR: 3.09; 95% CI: 1.36-7.04). CONCLUSION: Patients with a distressed personality and high levels of pre-implantation device-related concerns had a poorer prognosis, independent of other risk markers including shocks. This subgroup of patients should be identified in clinical practice and would likely benefit from a combined distress management programme and cardiac rehabilitation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Amiodarone or an Implantable Cardioverter–Defibrillator for Congestive Heart Failure
Bardy, G. H., Lee, K. L., Mark, D. B., Poole, J. E., Packer, D. L., Boineau, R., Domanski, M., Troutman, C., Anderson, J., Johnson, G., et al. (2005) · New England Journal of Medicine · doi:10.1056/nejmoa043399 · Cited by 6,552
The epidemiology, pathophysiology, and management of psychosocial risk factors in cardiac practice
Rozanski, A., Blumenthal, J. A., Davidson, K. W., Saab, P. G., & Kubzansky, L. (2005) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2004.12.005 · Cited by 1,238 · cited 1×
“Rozanski et al.(28) has previously emphasised the importance of studying the influence of clustering of psychosocial risk factors, as the tendency is to study single risk factors, which is less likely to capture the real risk factor burden to individual patients.”
BackgroundEmotional and physical precipitants of ventricular arrhythmia
Lampert, R., Joska, T., Burg, M. M., Batsford, W. P., McPherson, C. A., & Jain, D. (2002) · Circulation · doi:10.1161/01.cir.0000031733.51374.c1 · Cited by 347
Székely, A., Balog, P., Benkö, E., Breuer, T., Székely, J., Kertai, M. D., Horkay, F., Kopp, M. S., & Thayer, J. F. (2007) · Psychosomatic Medicine · doi:10.1097/psy.0b013e31814b8c0f · Cited by 204 · cited 1×
“…the role of psychological factors as risk factors for mortality in ICD patients are scarce, despite factors such as depression, 10,11 anxiety, 12,13 and Type D personality 14–16 being associated with increased risk of mortality in patients with both coronary artery disease (CAD) and heart…”
BackgroundLampert, R., Shusterman, V., Burg, M., McPherson, C., Batsford, W., Goldberg, A., & Soufer, R. (2009) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2008.10.053 · Cited by 116
Risk of Ventricular Arrhythmia After Implantable Defibrillator Treatment in Anxious Type D Patients
van den Broek, K. C., Nyklíček, I., van der Voort, P. H., Alings, M., Meijer, A., & Denollet, J. (2009) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2009.04.043 · Cited by 110 · cited 1×
“9 In the latter study, anxious patients with a Type D personality (i.e. patients with both a Type D personality and high levels of anxiety) had a higher risk for ventricular arrhythmia.”
BackgroundType D personality and cardiac mortality in patients with chronic heart failure
Schiffer, A. A., Smith, O. R. F., Pedersen, S. S., Widdershoven, J. W., & Denollet, J. (2010) · International Journal of Cardiology · doi:10.1016/j.ijcard.2008.12.090 · Cited by 83 · cited 2×
“14–16 A recently published study demonstrated that Type D personality also increases the risk of adverse clinical outcome in patients treated with ICD therapy.”
BackgroundSelf-citationPiotrowicz, K., Noyes, K., Lyness, J. M., McNitt, S., Andrews, M. L., Dick, A., Hall, W. J., Moss, A. J., & Zareba, W. (2006) · European Heart Journal · doi:10.1093/eurheartj/ehl485 · Cited by 68 · cited 3×
“17–19 The objective of the current study was to examine the influence of Type D personality and ICD patient concerns at the time of implantation on mortality in a cohort of consecutively implanted ICD patients.”
BackgroundPedersen, S. S., Denollet, J., de Jonge, P., Simsek, C., Serruys, P. W., & van Domburg, R. T. (2009) · Journal of General Internal Medicine · doi:10.1007/s11606-009-1054-1 · Cited by 31 · cited 1×
“9 Studies examining the role of psychological factors as risk factors for mortality in ICD patients are scarce, despite factors such as depression, 10,11 anxiety, 12,13 and Type D personality 14–16 being associated with increased risk of mortality in patients with both coronary artery disease (CAD)…”
BackgroundSelf-citation
Cited by
Priori, S. G., Blomström-Lundqvist, C., Mazzanti, A., Blom, N., Borggrefe, M., Camm, J., Elliott, P. M., Fitzsimons, D., Hatala, R., Hindricks, G., et al. (2015) · European Heart Journal · doi:10.1093/eurheartj/ehv316 · Cited by 3,893
(2015) · Europace · doi:10.1093/europace/euv319 · Cited by 1,592
Grande, G., Romppel, M., & Barth, J. (2012) · Annals of Behavioral Medicine · doi:10.1007/s12160-011-9339-0 · Cited by 230
The interpersonally sensitive disposition and health: An integrative review.
Marin, T. J., & Miller, G. E. (2013) · Psychological Bulletin · doi:10.1037/a0030800 · Cited by 79
Pedersen, S. S., Nielsen, J. C., Wehberg, S., Jørgensen, O. D., Riahi, S., Haarbo, J., Philbert, B. T., Larsen, M. L., & Johansen, J. B. (2021) · General Hospital Psychiatry · doi:10.1016/j.genhosppsych.2021.07.003 · Cited by 32
“Identification of patients at risk of new onset distress after implantation is important due to potential impairments to their QoL [4,8], and risk of non-adherence, ventricular tachyarrhythmias and mortality [5,6].”
BackgroundMethodInfluentialSelf-citation
Metadata
- Authors
- Pedersen, S. S., van den Broek, K. C., Erdman, R. A. M., Jordaens, L., & Theuns, D. A. M. J.
- Venue
- Europace
- Publisher
- Oxford University Press (OUP)
- Published
- 2010-08-18
- Volume
- 12
- Issue
- 10
- Pages
- 1446-1452
- ISSN
- 1099-5129 (ISSN-L)
- 1532-2092
- OpenAlex
- W1993976845
- Cited by
- 80
- References
- 9
- FWCI
- 7.77
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Pre-implantation implantable cardioverter defibrillator concerns and Type D personality increase the risk of mortality in patients with an implantable cardioverter defibrillator. https://app.cochat.ai/papers/10.1093/europace/euq296
- The paper
- Pedersen, S. S., van den Broek, K. C., Erdman, R. A. M., Jordaens, L., & Theuns, D. A. M. J. (2010). Pre-implantation implantable cardioverter defibrillator concerns and Type D personality increase the risk of mortality in patients with an implantable cardioverter defibrillator. Europace. https://doi.org/10.1093/europace/euq296