CoChat

Effects of closed-loop stimulation vs. DDD pacing on haemodynamic variations and occurrence of syncope induced by head-up tilt test in older patients with refractory cardioinhibitory vasovagal syncope: the Tilt test-Induced REsponse in Closed-loop Stimulation multicentre, prospective, single blind, randomized study

Open access
Palmisano, Pietro, Dell’Era, Gabriele, Russo, Vincenzo, Zaccaria, Maria, Mangia, Rolando, Bortnik, Miriam, De Vecchi, Federica, Giubertoni, Ailia, Patti, Fabiana, Magnani, Andrea, Nigro, Gerardo, Rago, Anna, Occhetta, Eraldo, Accogli, Michele · 2018 · EP Europace
Cited by 66

The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.

Abstract

Aims: Closed-loop stimulation (CLS) seemed promising in preventing the recurrence of vasovagal syncope (VVS) in patients with a cardioinhibitory response to head-up tilt test (HUTT) compared with conventional pacing. We hypothesized that the better results of this algorithm are due to its quick reaction in high-rate pacing delivered in the early phase of vasovagal reflex, which increase the cardiac output and the blood pressure preventing loss of consciousness. Methods and results: This prospective, randomized, single-blind, multicentre study was designed as an intra-patient comparison and enrolled 30 patients (age 62.2 ± 13.5 years, males 60.0%) with cardioinhibitory VVS, carrying a dual-chamber pacemaker incorporating CLS algorithm. Two HUTTs were performed one week apart: one during DDD-CLS 60-130/min pacing and the other during DDD 60/min pacing; patients were randomly and blindly assigned to two groups: in one the first HUTT was performed in DDD-CLS (n = 15), in the other in DDD (n = 15). Occurrence of syncope and haemodynamic variations induced by HUTT was recorded during the tests. Compared with DDD, DDD-CLS significantly reduced the occurrence of syncope induced by HUTT (30.0% vs. 76.7%; P < 0.001). In the patients who had syncope in both DDD and DDD-CLS mode, DDD-CLS significantly delayed the onset of syncope during HUTT (from 20.8 ± 3.9 to 24.8 ± 0.9 min; P = 0.032). The maximum fall in systolic blood pressure recorded during HUTT was significantly lower in DDD-CLS compared with DDD (43.2 ± 30.3 vs. 65.1 ± 25.8 mmHg; P = 0.004). Conclusion: In patients with cardioinhibitory VVS, CLS reduces the occurrence of syncope induced by HUTT, compared with DDD pacing. When CLS is not able to abort the vasovagal reflex, it seems to delay the onset of syncope.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/europace/eux015

Cites

9 of 9 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 66

Metadata

Authors
Palmisano, P., Dell’Era, G., Russo, V., Zaccaria, M., Mangia, R., Bortnik, M., De Vecchi, F., Giubertoni, A., Patti, F., Magnani, A., Nigro, G., Rago, A., Occhetta, E., & Accogli, M.
Venue
EP Europace
Published
2017-04-12
Volume
20
Issue
5
Pages
859-866
ISSN
  • 1099-5129 (ISSN-L)
  • 1532-2092
OpenAlex
W2606213579
Cited by
66
References
9
FWCI
7.58
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.