Detection of Plasmodium falciparum by Polymerase Chain Reaction in a Field Study
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Detection and typing of Plasmodium vivax by the polymerase chain reaction (PCR) was evaluated in a prospective blinded comparative field study in Thailand. PCR amplification of the circumsporozoite (CS) gene was compared with microscopy for the detection of P. vivax in blood samples from 174 Thai Rangers and 50 malaria-free Bangkok residents. For PCR analysis, filter paper specimens collected by finger prick were randomly processed and blindly interpreted for the presence of the CS gene of P. vivax. The VK210 and VK247 CS variants of P. vivax were detected by specific fluorescein or radiolabeled oligoprobes. Autoradiography with 32P-labeled probes and enhanced chemoluminescent detection with fluorescein-labeled probes identified 91% and 96%, respectively, of 119 microscopically confirmed infections; both systems detected < 100 parasites/microL. Compared with microscopy, the specificity of PCR and radiometric or enhanced chemoluminescent detection was 96% and 90%, respectively. The ease of collection and transport of filter-paper specimens combined with the sensitive and specific detection of allelic genes of P. vivax by PCR suggests that this method may prove to be a valuable tool for epidemiologic and heterogeneity studies of P. vivax.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Barker, R. H., Banchongaksorn, T., Courval, J. M., Suwonkerd, W., Rimwungtragoon, K., & Wirth, D. F. (1992) · The American Journal of Tropical Medicine and Hygiene · doi:10.4269/ajtmh.1992.46.416 · Cited by 148
Brown, A. E., Kain, K. C., Pipithkul, J., & Webster, H. K. (1992) · Transactions of the Royal Society of Tropical Medicine and Hygiene · doi:10.1016/0035-9203(92)90147-5 · Cited by 136
Self-citation
Cited by
Rapid Diagnostic Tests for Malaria Parasites
Moody, A. (2002) · Clinical Microbiology Reviews · doi:10.1128/cmr.15.1.66-78.2002 · Cited by 1,418
“(62), using two amplification systems, K1-14 (DNA) and CS, used PCR to monitor the response to therapy in 33 patients with P.”
MethodOkell, L. C., Ghani, A. C., Lyons, E., & Drakeley, C. J. (2009) · The Journal of Infectious Diseases · doi:10.1086/644781 · Cited by 532
Imported Malaria: Prospective Analysis of Problems in Diagnosis and Management
Kain, K. C., Harrington, M. A., Tennyson, S., & Keystone, J. S. (1998) · Clinical Infectious Diseases · doi:10.1086/514616 · Cited by 371
Self-citationReal-Time PCR for Detection and Identification of Plasmodium spp
Mangold, K. A., Manson, R. U., Koay, E. S. C., Stephens, L., Regner, M., Thomson, R. B., Peterson, L. R., & Kaul, K. L. (2005) · Journal of Clinical Microbiology · doi:10.1128/jcm.43.5.2435-2440.2005 · Cited by 278
Nested PCR Analysis of Plasmodium Parasites
Snounou, G., & Singh, B. (2003) · Malaria Methods and Protocols · doi:10.1385/1-59259-271-6:189 · Cited by 279
Metadata
- Authors
- Sethabutr, O., Brown, A. E., Panyim, S., Kain, K. C., Webster, H. K., & Echeverria, P.
- Venue
- Journal of Infectious Diseases
- Publisher
- Oxford University Press (OUP)
- Published
- 1992-07-01
- Volume
- 166
- Issue
- 1
- Pages
- 145-148
- ISSN
- 0022-1899 (ISSN-L)
- 1537-6613
- OpenAlex
- W2092504869
- Cited by
- 117
- References
- 2
- FWCI
- 4.58
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.