Aberrations and adaptive optics in super-resolution microscopy
Open accessThe DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.
Abstract
As one of the most powerful tools in the biological investigation of cellular structures and dynamic processes, fluorescence microscopy has undergone extraordinary developments in the past decades. The advent of super-resolution techniques has enabled fluorescence microscopy - or rather nanoscopy - to achieve nanoscale resolution in living specimens and unravelled the interior of cells with unprecedented detail. The methods employed in this expanding field of microscopy, however, are especially prone to the detrimental effects of optical aberrations. In this review, we discuss how super-resolution microscopy techniques based upon single-molecule switching, stimulated emission depletion and structured illumination each suffer from aberrations in different ways that are dependent upon intrinsic technical aspects. We discuss the use of adaptive optics as an effective means to overcome this problem.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Imaging Intracellular Fluorescent Proteins at Nanometer Resolution
Betzig, E., Patterson, G. H., Sougrat, R., Lindwasser, O. W., Olenych, S., Bonifacino, J. S., Davidson, M. W., Lippincott-Schwartz, J., & Hess, H. F. (2006) · Science · doi:10.1126/science.1127344 · Cited by 8,772 · cited 1×
“We consider three types of fluorescence-based super-resolution microscopy: single-molecule switching (SMS) microscopy [4–6], stimulated emission depletion (STED) microscopy [7] and structured illumination microscopy (SIM) [8].”
MethodSub-diffraction-limit imaging by stochastic optical reconstruction microscopy (STORM)
Rust, M. J., Bates, M., & Zhuang, X. (2006) · Nature Methods · doi:10.1038/nmeth929 · Cited by 8,078 · cited 1×
“We consider three types of fluorescence-based super-resolution microscopy: single-molecule switching (SMS) microscopy [4–6], stimulated emission depletion (STED) microscopy [7] and structured illumination microscopy (SIM) [8].”
MethodHell, S. W., & Wichmann, J. (1994) · Optics Letters · doi:10.1364/ol.19.000780 · Cited by 6,065
Gustafsson, M. G. L. (2000) · Journal of Microscopy · doi:10.1046/j.1365-2818.2000.00710.x · Cited by 3,786
Ultra-High Resolution Imaging by Fluorescence Photoactivation Localization Microscopy
Hess, S. T., Girirajan, T. P. K., & Mason, M. D. (2006) · Biophysical Journal · doi:10.1529/biophysj.106.091116 · Cited by 3,605 · cited 1×
“We consider three types of fluorescence-based super-resolution microscopy: single-molecule switching (SMS) microscopy [4–6], stimulated emission depletion (STED) microscopy [7] and structured illumination microscopy (SIM) [8].”
MethodGustafsson, M. G. L., Shao, L., Carlton, P. M., Wang, C. J. R., Golubovskaya, I. N., Cande, W. Z., Agard, D. A., & Sedat, J. W. (2008) · Biophysical Journal · doi:10.1529/biophysj.107.120345 · Cited by 1,557 · cited 1×
“This pattern is rotated and translated to a number of different positions in order to acquire a sequence of images that is processed to derive the super-resolution image [33].”
BackgroundPavani, S. R. P., Thompson, M. A., Biteen, J. S., Lord, S. J., Liu, N., Twieg, R. J., Piestun, R., & Moerner, W. E. (2009) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0900245106 · Cited by 1,040
Interferometric fluorescent super-resolution microscopy resolves 3D cellular ultrastructure
Shtengel, G., Galbraith, J. A., Galbraith, C. G., Lippincott-Schwartz, J., Gillette, J. M., Manley, S., Sougrat, R., Waterman, C. M., Kanchanawong, P., Davidson, M. W., et al. (2009) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0813131106 · Cited by 888 · cited 1×
“Other methods employ two opposing objectives in order to extract 3D information [19,20].”
MethodThree-dimensional sub–100 nm resolution fluorescence microscopy of thick samples
Juette, M. F., Gould, T. J., Lessard, M. D., Mlodzianoski, M. J., Nagpure, B. S., Bennett, B. T., Hess, S. T., & Bewersdorf, J. (2008) · Nature Methods · doi:10.1038/nmeth.1211 · Cited by 812
Theory and Practice of Scanning Optical Microscopy
Dainty, J. C. (1985) · Optica Acta: International Journal of Optics · doi:10.1080/713821694 · Cited by 766
Lynch, D. K. (1987) · Journal of the Optical Society of America A · doi:10.1364/josaa.4.000558 · Cited by 754 · cited 1×
“hampðxÞ is the amplitude (rather than intensity) PSF [34], defined as”
BackgroundWalburn, D. (2009) · Local Economy: The Journal of the Local Economy Policy Unit · doi:10.1080/02690940903137865 · Cited by 693
Adaptive optical microscopy: the ongoing quest for a perfect image
Booth, M. J. (2014) · Light: Science & Applications · doi:10.1038/lsa.2014.46 · Cited by 645
Self-citationBooth, M. J. (2007) · Philosophical Transactions of the Royal Society A Mathematical Physical and Engineering Sciences · doi:10.1098/rsta.2007.0013 · Cited by 552
Self-citationAdvanced Optical Imaging Theory
Gu, M. (2000) · Springer Series in Optical Sciences · doi:10.1007/978-3-540-48471-4 · Cited by 510
Diffraction-unlimited all-optical imaging and writing with a photochromic GFP
Grotjohann, T., Testa, I., Leutenegger, M., Bock, H., Urban, N. T., Lavoie-Cardinal, F., Willig, K. I., Eggeling, C., Jakobs, S., & Hell, S. W. (2011) · Nature · doi:10.1038/nature10497 · Cited by 501 · cited 1×
“Furthermore, all the super-resolution techniques that share the conceptual framework of reversible saturable optical fluorescence transitions [38] microscopy would benefit from AO in a similar fashion as STED, as the technical aspects of their optical set-ups are similar.”
BackgroundResolution scaling in STED microscopy
Harke, B., Keller, J., Ullal, C. K., Westphal, V., Schönle, A., & Hell, S. W. (2008) · Optics Express · doi:10.1364/oe.16.004154 · Cited by 438
Adaptive aberration correction in a confocal microscope
Booth, M. J., Neil, M. A. A., Juškaitis, R., & Wilson, T. (2002) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.082544799 · Cited by 418
Self-citationAdaptive optics enables 3D STED microscopy in aberrating specimens
Gould, T. J., Burke, D., Bewersdorf, J., & Booth, M. J. (2012) · Optics Express · doi:10.1364/oe.20.020998 · Cited by 315 · cited 4×
“This procedure is aided by the use of a SLM, as automated feedback routines can be implemented using image optimization [29,30].”
BackgroundMethodSelf-citationA compact STED microscope providing 3D nanoscale resolution
Wildanger, D., Medda, R., Kastrup, L., & Hell, S. W. (2009) · Journal of Microscopy · doi:10.1111/j.1365-2818.2009.03188.x · Cited by 303 · cited 2×
“In some situations, both the 2D and 3D patterns are combined by superimposing two beams with opposite circular polarizations [9,22].”
BackgroundCoaligned Dual-Channel STED Nanoscopy and Molecular Diffusion Analysis at 20 nm Resolution
Göttfert, F., Wurm, C. A., Mueller, V., Berning, S., Cordes, V. C., Honigmann, A., & Hell, S. W. (2013) · Biophysical Journal · doi:10.1016/j.bpj.2013.05.029 · Cited by 298 · cited 1×
“The resolution of the resulting image is much smaller than the size of the original excitation focus, reportedly around 20 nm (xy plane) in biological specimens [9,10].”
BackgroundAquino, D., Schönle, A., Geisler, C., Middendorff, C. V., Wurm, C. A., Okamura, Y., Lang, T., Hell, S. W., & Egner, A. (2011) · Nature Methods · doi:10.1038/nmeth.1583 · Cited by 254
Auksorius, E., Boruah, B. R., Dunsby, C., Lanigan, P. M. P., Kennedy, G., Neil, M. A. A., & French, P. M. W. (2008) · Optics Letters · doi:10.1364/ol.33.000113 · Cited by 190
Izeddin, I., El Beheiry, M., Andilla, J., Ciepielewski, D., Darzacq, X., & Dahan, M. (2012) · Optics Express · doi:10.1364/oe.20.004957 · Cited by 167
Adaptive optics for structured illumination microscopy
Débarre, D., Botcherby, E. J., Booth, M. J., & Wilson, T. (2008) · Optics Express · doi:10.1364/oe.16.009290 · Cited by 164 · cited 1×
“Previous work on AO for sectioning (rather than super-resolution), SIM has shown that the imaging properties of such a system are dominated by its ability to reliably image the high spatial frequency of the pattern, even though other frequencies are also present [35].”
BackgroundSelf-citationAdaptive optics correction of specimen-induced aberrations in single-molecule switching microscopy
Burke, D. L., Patton, B., Huang, F., Bewersdorf, J., & Booth, M. J. (2015) · Optica · doi:10.1364/optica.2.000177 · Cited by 122 · cited 3×
“[14] implemented an AO system for feedback aberration correction in a STORM microscope.”
BackgroundMethodSelf-citationThree dimensional single molecule localization using a phase retrieved pupil function
Liu, S., Kromann, E. B., Krueger, W. D., Bewersdorf, J., & Lidke, K. A. (2013) · Optics Express · doi:10.1364/oe.21.029462 · Cited by 90
3‐D stimulated emission depletion microscopy with programmable aberration correction
Lenz, M. O., Sinclair, H. G., Savell, A., Clegg, J., Brown, A. C. N., Davis, D. M., Dunsby, C. W., Neil, M. A. A., & French, P. M. W. (2013) · Journal of Biophotonics · doi:10.1002/jbio.201300041 · Cited by 88
Hu, Y., Zhu, Q., Elkins, K., Tse, K. Y., Li, Y., Fitzpatrick, J. A. J., Verma, I. M., & Cang, H. (2013) · Optical Nanoscopy · doi:10.1186/2192-2853-2-7 · Cited by 82
Effects of primary aberrations on the fluorescence depletion patterns of STED microscopy
Deng, S., Liu, L., Cheng, Y., Li, R., & Xu, Z. (2010) · Optics Express · doi:10.1364/oe.18.001657 · Cited by 80
Enhanced resolution through thick tissue with structured illumination and adaptive optics
Thomas, B. A., Wolstenholme, A. J., Chaudhari, S. N., Kipreos, E. T., & Kner, P. (2015) · Journal of Biomedical Optics · doi:10.1117/1.jbo.20.2.026006 · Cited by 71 · cited 2×
“The correction in these paths could be performed simultaneously using a single DM, which would be ideal for the fluorescence emission [36].”
BackgroundMethodAuto-aligning stimulated emission depletion microscope using adaptive optics
Gould, T. J., Kromann, E. B., Burke, D. L., Booth, M. J., & Bewersdorf, J. (2013) · Optics Letters · doi:10.1364/ol.38.001860 · Cited by 61
Self-citationInvestigation of the influence of the aberration induced by a plane interface on STED microscopy
Deng, S., Liu, L., Cheng, Y., Li, R., & Xu, Z. (2009) · Optics Express · doi:10.1364/oe.17.001714 · Cited by 55
Single‐Molecule Super‐Resolution Light‐Sheet Microscopy
Hu, Y., Zimmerley, M., Li, Y., Watters, R., & Cang, H. (2014) · ChemPhysChem · doi:10.1002/cphc.201300732 · Cited by 52
Cited by
Adaptive optical fluorescence microscopy
Ji, N. (2017) · Nature Methods · doi:10.1038/nmeth.4218 · Cited by 527
Adaptive optics for high-resolution imaging
Hampson, K. M., Turcotte, R., Miller, D. T., Kurokawa, K., Males, J. R., Ji, N., & Booth, M. J. (2021) · Nature Reviews Methods Primers · doi:10.1038/s43586-021-00066-7 · Cited by 291
Self-citationMetasurfaces for biomedical applications: imaging and sensing from a nanophotonics perspective
Zhang, S., Wong, C. L., Zeng, S., Bi, R., Tai, K., Dholakia, K., & Olivo, M. (2020) · Nanophotonics · doi:10.1515/nanoph-2020-0373 · Cited by 270
Superresolution structured illumination microscopy reconstruction algorithms: a review
Chen, X., Zhong, S., Hou, Y., Cao, R., Wang, W., Li, D., Dai, Q., Kim, D., & Xi, P. (2023) · Light: Science & Applications · doi:10.1038/s41377-023-01204-4 · Cited by 229
Möckl, L., & Moerner, W. E. (2020) · Journal of the American Chemical Society · doi:10.1021/jacs.0c08178 · Cited by 181
Metadata
- Authors
- Booth, M., Andrade, D., Burke, D., Patton, B., & Zurauskas, M.
- Venue
- Microscopy
- Publisher
- Oxford University Press (OUP)
- Published
- 2015-06-28
- Volume
- 64
- Issue
- 4
- Pages
- 251-261
- ISSN
- 2050-5698 (ISSN-L)
- 2050-5701
- OpenAlex
- W2169715613
- Cited by
- 168
- References
- 34
- FWCI
- 6.63
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.