The DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.
Multiplex quantitative PCR using self-quenched primers labeled with a single fluorophore
Open accessAbstract
Multiplex quantitative PCR based on novel design of fluorescent primers is described. Fluorogenic primers are labeled with a single fluorophore on a base close to the 3' end with no quencher required. A tail of 5-7 nt is added to the 5' end of the primer to form a blunt-end hairpin when the primer is not incorporated into a PCR product. This design provides a low initial fluorescence of the primers that increases up to 8-fold upon formation of the PCR product. The hairpin oligonucleotides (DeltaG from -1.6 to -5.8 kcal/mol) may be as efficient as linear primers and provide additional specificity to the PCR by preventing primer-dimers and mispriming. Multiple fluorogenic primers were designed by specialized software and used for real-time quantitation of c-myc and IL-4 cDNAs in the presence of reference genes such as beta-actin, GAPDH and 18S rRNA. Targets of 10-10(7) copies were detected with precision in PCR using FAM-labeled primers for variable genes and JOE-labeled primers for the reference genes. This method was also used to detect single nucleotide polymorphism of the human retinal degeneration gene by allele-specific PCR with end-point detection using a fluorescent plate reader or a UV-transilluminator. We conclude that fluorogenic mono-labeled primers are an efficient and cost-effective alternative to FRET-labeled oligonucleotides.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Principles of Fluorescence Spectroscopy
Lakowicz, J. R. (1999) · Springer eBooks · doi:10.1007/978-1-4757-3061-6 · Cited by 26,947
Heid, C. A., Stevens, J., Livak, K. J., & Williams, P. M. (1996) · Genome Research · doi:10.1101/gr.6.10.986 · Cited by 6,174
Molecular Beacons: Probes that Fluoresce upon Hybridization
Tyagi, S., & Kramer, F. R. (1996) · Nature Biotechnology · doi:10.1038/nbt0396-303 · Cited by 4,155
Bustin, S. (2000) · Journal of Molecular Endocrinology · doi:10.1677/jme.0.0250169 · Cited by 3,872
Kinetic PCR Analysis: Real-time Monitoring of DNA Amplification Reactions
Higuchi, R., Fockler, C., Dollinger, G., & Watson, R. (1993) · Nature Biotechnology · doi:10.1038/nbt0993-1026 · Cited by 2,159
Livak, K. J., Flood, S. J., Marmaro, J., Giusti, W., & Deetz, K. (1995) · Genome Research · doi:10.1101/gr.4.6.357 · Cited by 1,603
Continuous Fluorescence Monitoring of Rapid Cycle DNA Amplification
Wittwer, C. T., Herrmann, M. G., Moss, A. A., & Rasmussen, R. P. (2013) · BioTechniques · doi:10.2144/000114043 · Cited by 1,274
Quantitative RT-PCR: Pitfalls and Potential
Freeman, W. M., Walker, S. J., & Vrana, K. E. (1999) · BioTechniques · doi:10.2144/99261rv01 · Cited by 1,147
Seidel, C. A. M., Schulz, A., & Sauer, M. H. M. (1996) · The Journal of Physical Chemistry · doi:10.1021/jp951507c · Cited by 1,006
Allelic discrimination by nick-translation PCR with fluorgenic probes
Lee, L. G., Connell, C. R., & Bloch, W. (1993) · Nucleic Acids Research · doi:10.1093/nar/21.16.3761 · Cited by 749
Cited by
Real-Time PCR for mRNA Quantitation
Wong, M. L., & Medrano, J. F. (2005) · BioTechniques · doi:10.2144/05391rv01 · Cited by 1,786
The real-time polymerase chain reaction
Kubista, M., Andrade, J. M., Bengtsson, M., Forootan, A., Jonák, J., Lind, K., Sindelka, R., Sjöback, R., Sjögreen, B., Strömbom, L., et al. (2006) · Molecular Aspects of Medicine · doi:10.1016/j.mam.2005.12.007 · Cited by 1,515
Point-of-Care Diagnostics for Global Health
Yager, P., Domingo, G. J., & Gerdes, J. (2008) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.10.061807.160524 · Cited by 1,076
Spandidos, A., Wang, X., Wang, H., & Seed, B. (2010) · Nucleic Acids Research · doi:10.1093/nar/gkp1005 · Cited by 910
Real-time PCR in the microbiology laboratory
Mackay, I. M. (2004) · Clinical Microbiology and Infection · doi:10.1111/j.1198-743x.2004.00722.x · Cited by 807
Real-time reverse transcription PCR (qRT-PCR) and its potential use in clinical diagnosis
Bustin, S. A., & Mueller, R. (2005) · Clinical Science · doi:10.1042/cs20050086 · Cited by 529
Real-time PCR detection chemistry
Navarro, E., Serrano-Heras, G., Castaño, M. J., & Solera, J. (2015) · Clinica Chimica Acta · doi:10.1016/j.cca.2014.10.017 · Cited by 457
Advancing ecological understandings through technological transformations in noninvasive genetics
BEJA‐PEREIRA, A., OLIVEIRA, R., ALVES, P. C., SCHWARTZ, M. K., & LUIKART, G. (2009) · Molecular Ecology Resources · doi:10.1111/j.1755-0998.2009.02699.x · Cited by 457
Becherer, L., Borst, N., Bakheit, M., Frischmann, S., Zengerle, R., & von Stetten, F. (2020) · Analytical Methods · doi:10.1039/c9ay02246e · Cited by 429
Current and Developing Technologies for Monitoring Agents of Bioterrorism and Biowarfare
Lim, D. V., Simpson, J. M., Kearns, E. A., & Kramer, M. F. (2005) · Clinical Microbiology Reviews · doi:10.1128/cmr.18.4.583-607.2005 · Cited by 417
Fu, T.-J., Abbott, U. R., & Hatzos, C. (2002) · Journal of Agricultural and Food Chemistry · doi:10.1021/jf020599h · Cited by 403
Kulka, M., Alexopoulou, L., Flavell, R. A., & Metcalfe, D. D. (2004) · Journal of Allergy and Clinical Immunology · doi:10.1016/j.jaci.2004.03.049 · Cited by 351
Nazarenko, I. (2002) · Nucleic Acids Research · doi:10.1093/nar/30.9.2089 · Cited by 336
Self-citationSpecies determination – Can we detect and quantify meat adulteration?
Ballin, N. Z., Vogensen, F. K., & Karlsson, A. H. (2009) · Meat Science · doi:10.1016/j.meatsci.2009.06.003 · Cited by 302
Taylor, S. L. (2003) · Journal of Agricultural and Food Chemistry · doi:10.1021/jf030375e · Cited by 296
Fluorescence Properties and Photophysics of the Sulfoindocyanine Cy3 Linked Covalently to DNA
Sanborn, M. E., Connolly, B. K., Gurunathan, K., & Levitus, M. (2007) · The Journal of Physical Chemistry B · doi:10.1021/jp072912u · Cited by 296
Detection and monitoring of virus infections by real-time PCR
Watzinger, F., Ebner, K., & Lion, T. (2006) · Molecular Aspects of Medicine · doi:10.1016/j.mam.2005.12.001 · Cited by 281
Nucleic acid-based fluorescent probes and their analytical potential
Juskowiak, B. (2011) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-010-4304-5 · Cited by 252
Real-time RT-PCR: considerations for efficient and sensitive assay design
Peters, I. R., Helps, C. R., Hall, E. J., & Day, M. J. (2004) · Journal of Immunological Methods · doi:10.1016/j.jim.2004.01.003 · Cited by 159
Nemo‐Like Kinase Regulates Postnatal Skeletal Homeostasis
Canalis, E., Kranz, L., & Zanotti, S. (2014) · Journal of Cellular Physiology · doi:10.1002/jcp.24625 · Cited by 7
Metadata
- Authors
- Nazarenko, I.
- Venue
- Nucleic Acids Research
- Publisher
- Oxford University Press (OUP)
- Published
- 2002-05-01
- Volume
- 30
- Issue
- 9
- Pages
- 37e-37
- ISSN
- 0305-1048 (ISSN-L)
- 1362-4962
- OpenAlex
- W2157463520
- Cited by
- 279
- References
- 28
- FWCI
- 6.70
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.