Substantial biases in ultra-short read data sets from high-throughput DNA sequencing
Open accessThe DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Abstract
Novel sequencing technologies permit the rapid production of large sequence data sets. These technologies are likely to revolutionize genetics and biomedical research, but a thorough characterization of the ultra-short read output is necessary. We generated and analyzed two Illumina 1G ultra-short read data sets, i.e. 2.8 million 27mer reads from a Beta vulgaris genomic clone and 12.3 million 36mers from the Helicobacter acinonychis genome. We found that error rates range from 0.3% at the beginning of reads to 3.8% at the end of reads. Wrong base calls are frequently preceded by base G. Base substitution error frequencies vary by 10- to 11-fold, with A > C transversion being among the most frequent and C > G transversions among the least frequent substitution errors. Insertions and deletions of single bases occur at very low rates. When simulating re-sequencing we found a 20-fold sequencing coverage to be sufficient to compensate errors by correct reads. The read coverage of the sequenced regions is biased; the highest read density was found in intervals with elevated GC content. High Solexa quality scores are over-optimistic and low scores underestimate the data quality. Our results show different types of biases and ways to detect them. Such biases have implications on the use and interpretation of Solexa data, for de novo sequencing, re-sequencing, the identification of single nucleotide polymorphisms and DNA methylation sites, as well as for transcriptome analysis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures









Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“RNA-Seq is well known to suffer reproducible several fold biases in the number of DNA sequence reads obtained for different GC content genomic regions (Cheung et al., 2011; Dohm et al., 2008)”
From System wide analyses have underestimated protein abundances and the importance of transcription in mammals (2014) · cites this paper as Dohm et al., 2008
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
DNA sequencing with chain-terminating inhibitors
Sanger, F., Nicklen, S., & Coulson, A. R. (1977) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.74.12.5463 · Cited by 68,572 · cited 1×
“These technologies allow sequence determination much quicker and cheaper than the dideoxy chain terminator method presented by Sanger in 1977 (2).”
MethodGenome sequencing in microfabricated high-density picolitre reactors
Margulies, M., Egholm, M., Altman, W. E., Attiya, S., Bader, J. S., Bemben, L. A., Berka, J., Braverman, M. S., Chen, Y.-J., Chen, Z., et al. (2005) · Nature · doi:10.1038/nature03959 · Cited by 7,693
High-Resolution Profiling of Histone Methylations in the Human Genome
Barski, A., Cuddapah, S., Cui, K., Roh, T.-Y., Schones, D. E., Wang, Z., Wei, G., Chepelev, I., & Zhao, K. (2007) · Cell · doi:10.1016/j.cell.2007.05.009 · Cited by 6,845 · cited 1×
“For the human genome, ultra-short reads were applied in studies on chromatin analysis (11,12).”
MethodSpecific Enzymatic Amplification of DNA In Vitro: The Polymerase Chain Reaction
Mullis, K., Faloona, F., Scharf, S., Saiki, R., Horn, G., & Erlich, H. (1986) · Cold Spring Harbor Symposia on Quantitative Biology · doi:10.1101/sqb.1986.051.01.032 · Cited by 3,558 · cited 1×
“The adoption of high-throughput sequencing will revolutionize molecular biology research, similar to the invention of the polymerase chain reaction (PCR) twenty years ago (3).”
MethodShotgun bisulphite sequencing of the Arabidopsis genome reveals DNA methylation patterning
Cokus, S. J., Feng, S., Zhang, X., Chen, Z., Merriman, B., Haudenschild, C. D., Pradhan, S., Nelson, S. F., Pellegrini, M., & Jacobsen, S. E. (2008) · Nature · doi:10.1038/nature06745 · Cited by 2,256 · cited 1×
“In the context of DNA methylation site detection by shotgun bisulfite sequencing (21), the frequency of erroneous detection of C instead of T and vice versa is of particular interest.”
BackgroundRobertson, G., Hirst, M., Bainbridge, M., Bilenky, M., Zhao, Y., Zeng, T., Euskirchen, G., Bernier, B., Varhol, R., Delaney, A., et al. (2007) · Nature Methods · doi:10.1038/nmeth1068 · Cited by 1,454 · cited 1×
“For the human genome, ultra-short reads were applied in studies on chromatin analysis (11,12).”
MethodAccuracy and quality of massively parallel DNA pyrosequencing
Huse, S. M., Huber, J. A., Morrison, H. G., Sogin, M. L., & Welch, D. M. (2007) · Genome Biology · doi:10.1186/gb-2007-8-7-r143 · Cited by 1,282 · cited 3×
“(13) estimated that 39% of all errors that had passed GS20 quality filtering occur in homopolymer length detection.”
BackgroundWhole-genome sequencing and variant discovery in C. elegans
Hillier, L. W., Marth, G. T., Quinlan, A. R., Dooling, D., Fewell, G., Barnett, D., Fox, P., Glasscock, J. I., Hickenbotham, M., Huang, W., et al. (2008) · Nature Methods · doi:10.1038/nmeth.1179 · Cited by 404
Gene discovery and annotation using LCM-454 transcriptome sequencing
Emrich, S. J., Barbazuk, W. B., Li, L., & Schnable, P. S. (2007) · Genome Research · doi:10.1101/gr.5145806 · Cited by 381
Sampling the Arabidopsis Transcriptome with Massively Parallel Pyrosequencing
Weber, A. P. M., Weber, K. L., Carr, K., Wilkerson, C., & Ohlrogge, J. B. (2007) · Plant Physiology · doi:10.1104/pp.107.096677 · Cited by 366
Cited by
Items 501–600 of 1,001
Boocock, J., Chagné, D., Merriman, T. R., & Black, M. A. (2015) · BMC Genomics · doi:10.1186/s12864-015-2096-x · Cited by 33
“influences the read-depth when using Illumina sequencing [33].”
MethodOno, H., Ishii, K., Kozaki, T., Ogiwara, I., Kanekatsu, M., & Yamada, T. (2015) · BMC Genomics · doi:10.1186/s12864-015-2247-0 · Cited by 33
RNA-seq Using Next Generation Sequencing
Corney, D. C. (2013) · Materials and Methods · doi:10.13070/mm.en.3.203 · Cited by 33
Ragheb, M. N., Ford, C. B., Chase, M. R., Lin, P. L., Flynn, J. L., & Fortune, S. M. (2013) · BMC Genomics · doi:10.1186/1471-2164-14-145 · Cited by 32
Ma, W., & Wong, W. H. (2011) · Methods in enzymology on CD-ROM/Methods in enzymology · doi:10.1016/b978-0-12-385075-1.00003-2 · Cited by 32
Tailor: a computational framework for detecting non-templated tailing of small silencing RNAs
Chou, M.-T., Han, B., Hsiao, C.-P., Zamore, P. D., Weng, Z., & Hung, J. (2015) · Nucleic Acids Research · doi:10.1093/nar/gkv537 · Cited by 32
“For example, it is known that reads from Illumina HiSeq and Genome analyzer platforms have preferential A–C conversions (21,22) and a high error rate at the 3′ end of reads, which frequently leads to uncalled bases, i.”
BackgroundEstimating Phred scores of Illumina base calls by logistic regression and sparse modeling
Zhang, S., Wang, B., Wan, L., & Li, L. M. (2017) · BMC Bioinformatics · doi:10.1186/s12859-017-1743-4 · Cited by 31
“From previous research [9, 10] and our recent work [5], it should be noted that the error rates of the base calls in the Illumina platforms are related to the factors such as the signals after correction for color-, cyclic- and spatial crosstalk, the cycle number of current positions, the two most likely nucleotide ba…”
Backgroundde Witt, R. N., Kroukamp, H., van Zyl, W. H., Paulsen, I. T., & Volschenk, H. (2019) · FEMS Yeast Research · doi:10.1093/femsyr/foz047 · Cited by 31
Extracellular miRNAs in redox signaling: Health, disease and potential therapies
Ruiz, G. P., Camara, H., Fazolini, N. P. B., & Mori, M. A. (2021) · Free Radical Biology and Medicine · doi:10.1016/j.freeradbiomed.2021.05.004 · Cited by 31
Palmieri, N., & Schlötterer, C. (2009) · PLoS ONE · doi:10.1371/journal.pone.0006323 · Cited by 31
“Nevertheless, other biases caused by the sequencing process, such as a GC-content dependent production of reads [20], could also have a substantial effect on the estimated gene expression levels and these are not considered here.”
BackgroundA short survey of computational analysis methods in analysing ChIP-seq data
Kim, H., Kim, J., Selby, H. M., Gao, D., Tong, T., Phang, T. L., & Tan, A. C. (2011) · Human Genomics · doi:10.1186/1479-7364-5-2-117 · Cited by 31
“6 The uniform control model 5 does not hold due to the biases from non-specific fragments, such as random protein–DNA or antibody–DNA interactions, and the existence of sequencing 8 and mapping 2 biases or chromatin structure and genome copy number variations.”
BackgroundViturawong, T., Meissner, F., Butter, F., & Mann, M. (2013) · Cell Reports · doi:10.1016/j.celrep.2013.09.022 · Cited by 32
Accelerating error correction in high-throughput short-read DNA sequencing data with CUDA
Shi, H., Schmidt, B., Liu, W., & Müller‐Wittig, W. (2009) · IEEE International Parallel and Distributed Processing Symposium (IPDPS) · doi:10.1109/ipdps.2009.5160924 · Cited by 31
“A recent paper [ 6 ] has reported that error rates in Solexa/Illumina reads range from 0.3% at the beginning of a reads to 3.8% at the end of reads.”
BackgroundInfluentialVieira, G. A., & Prosdocimi, F. (2019) · PeerJ · doi:10.7717/peerj.6271 · Cited by 31
“321 The low coverage in segments with a pronounced AT-bias should be expected because 322 AT-rich regions are known to have reduced amplification in Illumina library preparation 323 protocols (Dohm et al., 2008; Aird et al., 2011; Oyola et al., 2012).”
BackgroundPhilippe, N., Boureux, A., Bréhélin, L., Tarhio, J., Commes, T., & Rivals, É. (2009) · Nucleic Acids Research · doi:10.1093/nar/gkp492 · Cited by 31
“Evidence of this bias was published for genome resequencing with the Solexa platform (23).”
BackgroundMethodEffects of short read quality and quantity on a de novo vertebrate transcriptome assembly
Garcia, T. I., Shen, Y., Catchen, J., Amores, A., Schartl, M., Postlethwait, J. H., & Walter, R. B. (2011) · Comparative Biochemistry and Physiology Part C Toxicology & Pharmacology · doi:10.1016/j.cbpc.2011.05.012 · Cited by 30
“The incidence of errors in this type of data increases with each additional nucleotide base call such that the distal ends are much more likely to have erroneous calls than the initial positions (Dohm et al. 2008).”
BackgroundDetecting Copy Number Variation via Next Generation Technology
Mason‐Suares, H., Landry, L. G., & Lebo, M. S. (2016) · Current Genetic Medicine Reports · doi:10.1007/s40142-016-0091-4 · Cited by 30
Donato, L., Scimone, C., Rinaldi, C., D’Angelo, R., & Sidoti, A. (2021) · Neural Computing and Applications · doi:10.1007/s00521-021-06188-z · Cited by 30
Li, X., Zhang, P., Wang, H., & Yu, Y. (2022) · BMC Genomics · doi:10.1186/s12864-022-08785-1 · Cited by 30
“531, two-sided), indicating “GC content bias”, which indicates that regions with high GC content tend to yield more read coverage [22], and further that RNA-seq may not contribute to the increase in expression levels of these genes.”
BackgroundInvestigation into the annotation of protocol sequencing steps in the sequence read archive
Alnasir, J. J., & Shanahan, H. P. (2015) · GigaScience · doi:10.1186/s13742-015-0064-7 · Cited by 30
“…that the majority of systematic errors were sequences preceded by a G; the most common being GGT, where a T is substituted for a G. Dohm et al. [10] also demonstrated that wrong base calls are frequently preceded by base G, thus indicating that the Illumina base-caller software has difficulty…”
BackgroundmiRNA Expression Profile Analysis in Kidney of Different Porcine Breeds
Oriol, T., Balcells, I., Núñez, J. I., Egea, R., Vera, G., Castelló, A., Tomás, A., & Sánchez, A. (2013) · PLoS ONE · doi:10.1371/journal.pone.0055402 · Cited by 30
“not each miRNA is amplified in the same proportion with high throughput sequencing [72,73] and the presence of isomiRs, which make difficult to perform an accurate filtering of sequences.”
BackgroundANALYSIS OF CONTEXT-DEPENDENT ERRORS FOR ILLUMINA SEQUENCING
Abnizova, I., Leonard, S. R., Skelly, T., BROWN, A., Jackson, D. K., Gourtovaia, M., Qi, G., Boekhorst, R. T., Faruque, N., Lewis, K., et al. (2012) · Journal of Bioinformatics and Computational Biology · doi:10.1142/s0219720012410053 · Cited by 30
Li, J., Jew, B., Zhan, L., Hwang, S., Coppola, G., Freimer, N. B., & Sul, J. H. (2019) · PLoS Computational Biology · doi:10.1371/journal.pcbi.1007556 · Cited by 30
“First, genome sequencing is known to have errors or biases[17, 18, 19, 20, 21], which might cause inaccuracy in detecting variants.”
BackgroundSequencing error correction without a reference genome
Sleep, J. A., SCHREIBER, A. W., & Baumann, U. (2013) · BMC Bioinformatics · doi:10.1186/1471-2105-14-367 · Cited by 29
“In [7], the occurrence of errors and their corresponding rates were investigated by looking at Illumina data sets (2.”
BackgroundResultAccurate sequencing of DNA motifs able to form alternative (non-B) structures
Weissensteiner, M. H., Cremona, M. A., Guiblet, W. M., Stoler, N., Harris, R. S., Čechová, M., Eckert, K. A., Chiaromonte, F., Huang, Y.-F., & Makova, K. D. (2023) · Genome Research · doi:10.1101/gr.277490.122 · Cited by 29
“Confounding factors, such as biased GC content, which are also known to influence sequencing accuracy in at least one of the technologies (Illumina), are in close interplay with non-B motifs, as they are often an inherent feature of such motifs (Dohm et al. 2008).”
BackgroundFuentes‐Pardo, A. P., Stanley, R. R. E., Bourne, C. M., Singh, R., Émond, K., Pinkham, L., McDermid, J. L., Andersson, L., & Ruzzante, D. E. (2024) · Evolutionary Applications · doi:10.1111/eva.13675 · Cited by 29
“We et al., 2008 ; Kolaczkowski et al., 2011).”
Li, J., Batcha, A. M. N., Gaining, B., & Mansmann, U. (2015) · Cancer Informatics · doi:10.4137/cin.s30793 · Cited by 29
“…technological and biological biases, as well as systematic errors, that may result from different sources including uncertainties in read alignments, 174,175 batch effects, 175 sequence effects and base calling sequence error, 174–177 platform-specific mechanistic problems, 178,179 and others.”
BackgroundPromises and pitfalls of Illumina sequencing for HIV resistance genotyping
Brumme, C. J., & Poon, A. F. Y. (2016) · Virus Research · doi:10.1016/j.virusres.2016.12.008 · Cited by 28
Performance evaluation of six popular short-read simulators
Milhaven, M., & Pfeifer, S. P. (2022) · Heredity · doi:10.1038/s41437-022-00577-3 · Cited by 29
“…model (Basic), the built-in platform-speci fi c error models The probability of an error ( P err ) is directly related to the base quality score ( q ) emitted by the sequencer ( P err = 10 ( − q /10) ), with error pro fi les varying by sequencing technology (Dohm et al. 2008; Nakamura et al. 2011).”
BackgroundGrätz, C., Schuster, M., Brandes, F., Meidert, A. S., Kirchner, B., Reithmair, M., Schelling, G., & Pfaffl, M. W. (2024) · Molecular Aspects of Medicine · doi:10.1016/j.mam.2024.101269 · Cited by 28
“This can be problematic in mutational analysis, especially if the base exchange occurred at a position prone to harbor single nucleotide polymorphisms (SNPs) (Dohm et al., 2008).”
Zhou, R., Ling, S., Zhao, W., Osada, N., Chen, S., Zhang, M., He, Z., Bao, H., Zhong, C., Zhang, B., et al. (2011) · Molecular Biology and Evolution · doi:10.1093/molbev/msr102 · Cited by 28
“Although the average raw error rate per site ranged from 0.6–1.5% in previous applications (Margulies et al. 2005; Dohm et al. 2008; Shendure and Ji 2008), the mean has decreased to 0.1–0.2% in our study, mainly due to technical improvements in the intervening period.”
BackgroundInfluentialZanders, S. E., Ma, X., RoyChoudhury, A., Hernandez, R. D., Demogines, A., Barker, B., Gu, Z., Bustamante, C. D., & Alani, E. (2010) · Genetics · doi:10.1534/genetics.110.120105 · Cited by 28
van Rosmalen, M., Janssen, B. M. G., Hendrikse, N. M., van der Linden, A. J., Pieters, P. A., Wanders, D., de Greef, T. F. A., & Merkx, M. (2017) · Journal of Biological Chemistry · doi:10.1074/jbc.m116.764225 · Cited by 28
Index-Free De Novo Assembly and Deconvolution of Mixed Mitochondrial Genomes
McComish, B. J., Hills, S. F. K., Biggs, P. J., & Penny, D. (2010) · Genome Biology and Evolution · doi:10.1093/gbe/evq029 · Cited by 28
“In practice, however, it has been reported that for GA reads, coverage is not uniform, but is correlated to GC content, perhaps due to AT-rich fragments being more prone to denaturation than GC-rich fragments (Dohm et al. 2008; Hillier et al. 2008).”
BackgroundAn Overview of the Computational Analyses and Discovery of Transcription Factor Binding Sites
Ladunga, I. (2010) · Methods in molecular biology · doi:10.1007/978-1-60761-854-6_1 · Cited by 27
Effect of PCR extension temperature on high-throughput sequencing
López-Barragán, M. J., Quiñones, M., Cui, K., Lemieux, J. E., Zhao, K., & Su, X. (2010) · Molecular and Biochemical Parasitology · doi:10.1016/j.molbiopara.2010.11.013 · Cited by 27
“With commonly used PCR conditions, repetitive AT-rich regions may not be amplified properly or not amplified at all, leading to an artificial lack of coverage in ATrich regions, whereas more GC-rich regions may be excessively amplified [3].”
BackgroundPark, M., Rhee, H., Park, J. H., Woo, H.-M., Choi, B., Kim, B. Y., Chung, K. W., Cho, Y., Kim, H. J., Jung, J., et al. (2014) · PLoS ONE · doi:10.1371/journal.pone.0086664 · Cited by 27
“Errors can arise from biases in target enrichment [3], sequence effects or base calling sequence errors [4–7], uncertainties in read alignments [6,7], batch effects [7] or platform-specific mechanistic problems [8,9].”
BackgroundDegradation in forensic trace DNA samples explored by massively parallel sequencing
Hanssen, E. N., Lyle, R., Egeland, T., & Gill, P. (2017) · Forensic Science International Genetics · doi:10.1016/j.fsigen.2017.01.002 · Cited by 27
MetaGen: reference-free learning with multiple metagenomic samples
Xing, X., Liu, J. S., & Zhong, W. (2017) · Genome biology · doi:10.1186/s13059-017-1323-y · Cited by 27
“For example, it was shown in [21] that Beta vulgaris BAC ZR-47B15 has nearly 7 times more coverage in GC-rich regions than in GC-poor regions.”
BackgroundThe quality and detection limits of mitochondrial heteroplasmy by long read nanopore sequencing
Slapnik, B., Šket, R., Črepinšek, K., Tesovnik, T., Bizjan, B. J., & Kovač, J. (2024) · Scientific Reports · doi:10.1038/s41598-024-78270-0 · Cited by 26
“Additionally, short-read sequencing has been shown to have higher error rates and increased miscalls in GC-rich regions 36 .”
BackgroundElder, H., Weis, V. M., Montalvo-Proaño, J., Mocellin, V. J. L., Baird, A. H., Meyer, E., & Bay, L. K. (2022) · Frontiers in Marine Science · doi:10.3389/fmars.2022.925845 · Cited by 26
“Although amplification of libraries was kept to a minimum (no more than 17 cycles of PCR) a certain amount of PCR bias is unavoidable and in a given cross certain regions may have been amplified more frequently (Dohm et al., 2008).”
ReQON: a Bioconductor package for recalibrating quality scores from next-generation sequencing data
Cabanski, C. R., Cavin, K., Bizon, C., Wilkerson, M. D., Parker, J. S., Wilhelmsen, K. C., Perou, C. M., Marron, J. S., & Hayes, D. N. (2012) · BMC Bioinformatics · doi:10.1186/1471-2105-13-221 · Cited by 26
“Most errors occur at the end of the read, due to technical aspects of the sequencing process [10].”
BackgroundLarge-scale DNA Barcode Library Generation for Biomolecule Identification in High-throughput Screens
Lyons, E., Sheridan, P. J., Tremmel, G., Miyano, S., & Sugano, S. (2017) · Scientific Reports · doi:10.1038/s41598-017-12825-2 · Cited by 26
“For example, when using Roche 454 sequencing the majority of errors are insertions and deletions 20 , when using Illumina the majority of errors are substitutions 21 , and other sequencing technologies can have significantly lower accuracy (92% in the case of the Oxford Nanopore MinION 22 ).”
MethodImpact of short-read sequencing on the misassembly of a plant genome
Wang, P., Meng, F., Moore, B. M., & Shiu, S. (2021) · BMC Genomics · doi:10.1186/s12864-021-07397-5 · Cited by 26
ngsComposer: an automated pipeline for empirically based NGS data quality filtering
Kuster, R. D., Yencho, G. C., & Olukolu, B. A. (2021) · Briefings in Bioinformatics · doi:10.1093/bib/bbab092 · Cited by 26
“Adapter sequences including barcode and restriction site motifs are expected to increase adapter detection sensitivity as these sequences are further upstream of the characteristic 3′ drop in sequence quality [21, 25].”
BackgroundFrésard, L., Leroux, S., Roux, P., Klopp, C., Fabre, S., Esquerré, D., Déhais, P., Djari, A., Gourichon, D., Lagarrigue, S., et al. (2015) · PLoS ONE · doi:10.1371/journal.pone.0126776 · Cited by 25
Assembly free comparative genomics of short‐read sequence data discovers the needles in the haystack
Cannon, C. H., Kua, C., ZHANG, D., & Harting, J. (2010) · Molecular Ecology · doi:10.1111/j.1365-294x.2009.04484.x · Cited by 25
“This type of bias has been observed before in SRS data (Dohm et al. 2008).”
BackgroundPhilippe, N., Samra, E. B., Boureux, A., Mancheron, A., Rufflé, F., Baï, Q., Vos, J. D., Rivals, É., & Commes, T. (2013) · Nucleic Acids Research · doi:10.1093/nar/gkt1300 · Cited by 25
“As mentioned in previous reports, the major cause of unmapped tags is sequence errors, and erroneous tag locations have been estimated to concern only 2% of the located sequences (19,28).”
Čejková, D., Strouhal, M., Norris, S. J., Weinstock, G. M., & Šmajs, D. (2015) · PLoS neglected tropical diseases · doi:10.1371/journal.pntd.0004110 · Cited by 25
“The majority of heterogeneous sites identified in this study represented transitions and not transversions, which, in general, are common Illumina sequencing errors; A!C was most common, followed by G!T transversions [59],[70].”
BackgroundInfluentialCandidate genes for grape white rot resistance based on SMRT and Illumina sequencing
Su, K., Guo, Y., Zhao, Y., Gao, H., Liu, Z., Li, K., Ma, L., & Guo, X. (2019) · BMC Plant Biology · doi:10.1186/s12870-019-2119-x · Cited by 25
Revisiting Rustrela Virus: New Cases of Encephalitis and a Solution to the Capsid Enigma
Pfaff, F., Breithaupt, A., Rubbenstroth, D., Nippert, S., Baumbach, C., Gerst, S., Langner, C., Wylezich, C., Ebinger, A., Höper, D. W., et al. (2022) · Microbiology Spectrum · doi:10.1128/spectrum.00103-22 · Cited by 25
Mapping-based genome size estimation
Natarajan, S., Gehrke, J., & Pucker, B. (2025) · BMC Genomics · doi:10.1186/s12864-025-11640-8 · Cited by 25
“Differences in the GC content of genomic regions were previously reported to have an impact 286 on the sequencing coverage [67, 68].”
Hansen, L. L., Kim, N.-K., Mariño‐Ramírez, L., & Landsman, D. (2011) · PLoS ONE · doi:10.1371/journal.pone.0029711 · Cited by 24
“Several studies have reported evidence of significant GC content bias in next generation sequencing [58,59,60,61].”
BackgroundQiu, P., Stevens, R. A., Wei, B., Lahser, F. C., Howe, A., Klappenbach, J. A., & Marton, M. J. (2015) · PLoS ONE · doi:10.1371/journal.pone.0122082 · Cited by 24
“Recent evaluations of biases generated in high throughput sequencing data have pinpointed the amplification step as the primary cause [21,22,23,24,25].”
BackgroundWang, Y., Yu, Y., Pan, B., Hao, P., Li, Y., Shao, Z., Xu, X., & Li, X. (2012) · BMC Systems Biology · doi:10.1186/1752-0509-6-s3-s21 · Cited by 24
“Dohm also demonstrated a higher rate of A to C error of Solexa data [20].”
BackgroundKim, T., & Park, P. J. (2014) · Cancer Research · doi:10.1158/0008-5472.can-14-1225 · Cited by 24
“this regard compared with other platforms (21), but its accuracy for longer homopolymers has not been carefully examined.”
BackgroundShort Barcodes for Next Generation Sequencing
Mir, K., Neuhaus, K., Bossert, M., & Schober, S. (2013) · PLoS ONE · doi:10.1371/journal.pone.0082933 · Cited by 24
“For example, on the Roche 454 [2] the predominant type of errors are insertions and deletions (indels) [3], while on the Illumina sequencing platforms [4] the most frequent errors are substitutions (see for example [5]).”
BackgroundGenome‐Wide Mapping and Analysis of Grapevine MicroRNAs and Their Potential Target Genes
Jiu, S., Zhu, X., Wang, J., Zhang, C., Mu, Q., Wang, C., & Fang, J. (2015) · The Plant Genome · doi:10.3835/plantgenome2014.12.0091 · Cited by 24
“Since the three Vitis species in this study belonged to diverse geographical origins, some genomic evolution events might have occurred to these miRNAs in various grapevines along with their speciation (Dohm et al., 2008).”
BackgroundA three-caller pipeline for variant analysis of cancer whole-exome sequencing data
Liu, Z.-K., Shang, Y., Chen, Z., & Bian, H. (2017) · Molecular Medicine Reports · doi:10.3892/mmr.2017.6336 · Cited by 24
Martin, R. C., Vining, K. J., & Dombrowski, J. E. (2018) · BMC Plant Biology · doi:10.1186/s12870-018-1275-8 · Cited by 24
Monger, C., Kelly, P. S., Gallagher, C., CLYNES, M. M., Barron, N., & Clarke, C. (2015) · Biotechnology Journal · doi:10.1002/biot.201500107 · Cited by 24
“This quality control check is important as over-fragmentation can result in low yield libraries while insufficient fragmentation may result in poor coverage [42, 43].”
BackgroundGréen, A., Gréen, H., Rehnberg, M., Svensson, A., Gunnarsson, C., & Jonasson, J. (2014) · Journal of Molecular Diagnostics · doi:10.1016/j.jmoldx.2014.09.006 · Cited by 23
Li, Y., Chen, W., Liu, E. Y., & Zhou, Y. (2012) · Statistics in Biosciences · doi:10.1007/s12561-012-9067-4 · Cited by 23
“Other factors, particularly those that are specific to a certain MPS technology, have been reported previously [51–53] and can also be useful for quality score recalibration [54].”
BackgroundDifferential and coherent processing patterns from small RNAs
Pundhir, S., & Gorodkin, J. (2015) · Scientific Reports · doi:10.1038/srep12062 · Cited by 23
“The GC content and various dinucleotide frequencies related to GC content have been shown to bias the transcript coverage 39,40 .”
Multiplex sequencing of bacterial artificial chromosomes for assembling complex plant genomes
Beier, S., Himmelbach, A., Schmutzer, T., Felder, M., Taudien, S., Mayer, K., Platzer, M., Stein, N., Scholz, U., & Mascher, M. (2016) · Plant Biotechnology Journal · doi:10.1111/pbi.12511 · Cited by 23
“Furthermore, the average contig coverage of all contigs from an individual BAC clone was calculated and a filter threshold of 90% of half of the average coverage was set [to account for uneven coverage in the sequenced region (Dohm et al., 2008)].”
MethodplantDARIO: web based quantitative and qualitative analysis of small RNA-seq data in plants
Bhattacharya, D. P., Fasold, M., Langenberger, D., Steger, G., Große, I., & Stadler, P. F. (2014) · Frontiers in Plant Science · doi:10.3389/fpls.2014.00708 · Cited by 23
“It is thus necessary to assess the quality and integrity of the experimental data before they are analyzed for biological content (Dohm et al., 2008; Linsen et al., 2009; Hansen et al., 2010).”
BackgroundTranscriptome analysis of an invasive weed Mikania micrantha
Huang, Y., Fang, X., Lu, L., Yan, Y., Chen, S. F., Hu, L., Zhu, C., Ge, X., & Shi, S. (2012) · Biologia Plantarum · doi:10.1007/s10535-012-0024-3 · Cited by 23
“In mixed samples from multiple individuals, the error rate may sometimes be higher than true polymorphisms of biological interest (Dohm et al. 2008, Shendure and Ji 2008).”
BackgroundUltra-deep sequencing of VHSV isolates contributes to understanding the role of viral quasispecies
Schönherz, A. A., Lorenzen, N., Guldbrandtsen, B., Buitenhuis, B., & Einer-Jensen, K. (2016) · Veterinary Research · doi:10.1186/s13567-015-0298-5 · Cited by 23
“66% [35].”
Nepomnyashchaya, Y. N., Artemov, A. V., Roumiantsev, S. A., Roumiantsev, A. G., & Zhavoronkov, A. A. (2012) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2012-0281 · Cited by 22
“This issue limits the sensitivity of measuring genomic representation in chromosomes [14, 39 – 41] .”
BackgroundEvaluation of a high-throughput, cost-effective Illumina library preparation kit
Tvedte, E. S., Michalski, J. M., Cheng, S., Patkus, R. S., Tallon, L. J., Sadzewicz, L., Bruno, V. M., da Silva, J. C. F., Rasko, D. A., & Hotopp, J. C. D. (2021) · Scientific Reports · doi:10.1038/s41598-021-94911-0 · Cited by 22
Quality-score guided error correction for short-read sequencing data using CUDA
Shi, H., Schmidt, B., Liu, W., & Müller‐Wittig, W. (2010) · Procedia Computer Science · doi:10.1016/j.procs.2010.04.125 · Cited by 22
Llorens, F., Hummel, M., Hostench, X. P., Ferrer, A., Pluvinet, R., Vivancos, A. P., Castillo, E., Iraola‐Guzmán, S., Mosquera, A. M., González‐Roca, E., et al. (2011) · BMC Genomics · doi:10.1186/1471-2164-12-326 · Cited by 22
“3’ adapters were recognized and trimmed using a script that penalizes mismatches to a lesser extent at read ends, following the distribution of sequencing errors along Illumina DGE reads [52].”
BackgroundSelf-citationWinnowing DNA for Rare Sequences: Highly Specific Sequence and Methylation Based Enrichment
Thompson, J. D., Shibahara, G., Rajan, S., Pel, J., & Marziali, A. (2012) · PLoS ONE · doi:10.1371/journal.pone.0031597 · Cited by 22
“Increasing sequencing coverage to target low abundance variants is complicated by the fact that errors in high throughput sequencing methods tend to have substantial sequence bias [4].”
BackgroundMethodStatistical inference of allelic imbalance from transcriptome data
Nothnagel, M., Wolf, A., Herrmann, A., Szafranski, K., Vater, I., Brosch, M., Huse, K., Siebert, R., Platzer, M., Hampe, J., et al. (2010) · Human Mutation · doi:10.1002/humu.21396 · Cited by 22
“…of defining and evaluating our proposed likelihood ratio test, we derived empirical estimates of the conditional miscalling probabilities of such experiments that corresponded well to earlier observations, and that likely reflect the signature of DNA polymerase infidelities [Dohm et al., 2008].”
ResultTranscriptomic Insights into the Life History of Bolidophytes, the Sister Lineage to Diatoms
Kessenich, C. R., Ruck, E. C., Schurko, A. M., Wickett, N. J., & Alverson, A. J. (2014) · Journal of Phycology · doi:10.1111/jpy.12222 · Cited by 22
“Based on these null expectations, we assessed the ploidy level in two diatoms, which are known to be vegetatively diploid (Drebes 1977, Chepurnov et al. 2004), and Bolidomonas, whose ploidy level is unknown.”
BackgroundMethodInfluentialThe impact of RNA secondary structure on read start locations on the Illumina sequencing platform
Price, A., Garhyan, J., & Gibas, C. (2017) · PLoS ONE · doi:10.1371/journal.pone.0173023 · Cited by 22
Partial short-read sequencing of a highly inbred Iberian pig and genomics inference thereof
Esteve‐Codina, A., Kofler, R., Himmelbauer, H., Luca Ferretti, A., Vivancos, A. P., Groenen, M. A. M., Folch, J. M., Rodríguez, M. C., & Miguel Pérez-enciso, A. (2011) · Heredity · doi:10.1038/hdy.2011.13 · Cited by 22
Self-citationToward Clinical Proteomics on a Next-Generation Sequencing Platform
Turner, D., Tuytten, R., Janssen, K. P. F., Lammertyn, J., Wuyts, J., Pollet, J. B. K., Eyckerman, S., Brown, C. G., & Kas, K. (2010) · Analytical Chemistry · doi:10.1021/ac102666n · Cited by 22
Bioinformatics analysis of various aspects in immunology
Salumets, A. (2024) · DSpace repository (University of Tartu) · Cited by 22
Ramlee, S. I., Esselink, D. G., Visser, R. G. F., SMULDERS, M. J. M., & Borm, T. (2017) · Frontiers in Plant Science · doi:10.3389/fpls.2017.01271 · Cited by 21
“In accordance with our results, several studies, e.g., Dohm et al. (2008), Li et al. (2010), and Minoche et al. (2011) claim that even though there is sufficient average depth of sequence coverage within sequencing datasets, sequencing bias leads to region of no sequence coverage within sequencing…”
ResultRNA-seq Using Next Generation Sequencing
Corney, D. C. (2012) · Materials and Methods · doi:10.13070/mm.en.2.203 · Cited by 21
Ramachandran, P., Palidwor, G., & Perkins, T. J. (2015) · Epigenetics & Chromatin · doi:10.1186/s13072-015-0028-2 · Cited by 21
“For example, GC-rich fragments are often overrepresented in ChIP-seq datasets, giving rise to the GCcontent bias [17, 18].”
BackgroundHöllbacher, B., Balázs, K., Heinig, M., & Uhlenhaut, N. H. (2020) · Computational and Structural Biotechnology Journal · doi:10.1016/j.csbj.2020.05.018 · Cited by 21
“‘‘Hyper-chippable” regions [16], GC rich regions [17] and non-random fragmentation [18] can introduce various biases or background.”
BackgroundPostnatal Arx transcriptional activity regulates functional properties of PV interneurons
Joseph, D. J., von Deimling, M., Hasegawa, Y., Cristancho, A. G., Ahrens‐Nicklas, R. C., Rogers, S. L., Risbud, R. M., McCoy, A. J., & Marsh, E. D. (2020) · iScience · doi:10.1016/j.isci.2020.101999 · Cited by 21
Statistical Issues in the Analysis of ChIP-Seq and RNA-Seq Data
Ghosh, D., & Qin, Z. S. (2010) · Genes · doi:10.3390/genes1020317 · Cited by 21
“There are many factors contributing to this bias such as GC content and repeat regions [96].”
BackgroundSmitz, N., van Hooft, P., Heller, R., Cornélis, D., Chardonnet, P., Kraus, R., Greyling, B., Crooijmans, R. P. M. A., Groenen, M. A. M., & MICHAUX, J. R. (2016) · Mammalian Biology · doi:10.1016/j.mambio.2016.07.047 · Cited by 21
“The buffalo population within this National Park is known to be affected by strong non-equilibrium conditions linked to a founder event (Smitz et al., 2014; Du Toit, 1954; Kappmeier et al., 1998).”
BackgroundThung, D. T., Beulen, L., Hehir-Kwa, J., & Faas, B. H. (2015) · Expert Review of Molecular Diagnostics · doi:10.1586/14737159.2015.973857 · Cited by 20
“MPS sequencing platforms are affected by a GC-content bias [76,77].”
BackgroundEvaluating coverage bias in next-generation sequencing of Escherichia coli
Gunasekera, S., Abraham, S., Stegger, M., Pang, S., Wang, P., Sahibzada, S., & O’Dea, M. A. (2021) · PLoS ONE · doi:10.1371/journal.pone.0253440 · Cited by 20
He, Z., Li, X., Ling, S., Fu, Y., Hungate, E. A., Shi, S., & Wu, C. (2013) · BMC Genomics · doi:10.1186/1471-2164-14-535 · Cited by 20
“The frequencies of base substitution error could vary by 10 to 11 fold, with A to C transversions being among the most frequent substitution errors and C to G transversions among the least frequent ones [27].”
BackgroundNext Generation Characterisation of Cereal Genomes for Marker Discovery
Visendi, P., Batley, J., & Edwards, D. (2013) · Biology · doi:10.3390/biology2041357 · Cited by 20
“As such, a significant shortfall of current sequencing and assembly methods is the poor resolution of repeats, often resulting in collapsed repeats [40,41] within assemblies.”
BackgroundSengupta, S., Gulukota, K., Zhu, Y., Ober, C., Naughton, K. A., Wentworth-Sheilds, W., & Ji, Y. (2015) · Nucleic Acids Research · doi:10.1093/nar/gkv953 · Cited by 20
“It has been noted (30,31) that these variant calls are not trustworthy due to artifacts and base calling errors in the data.”
gapFinisher: A reliable gap filling pipeline for SSPACE-LongRead scaffolder output
Kammonen, J., Smolander, O., Paulin, L. G., Pereira, P. A. B., Laine, P., Koskinen, P., Jernvall, J., & Auvinen, P. (2019) · PLoS ONE · doi:10.1371/journal.pone.0216885 · Cited by 20
McElhoe, J. A., & Holland, M. M. (2020) · Mitochondrion · doi:10.1016/j.mito.2020.02.005 · Cited by 20
Error Analysis of Deep Sequencing of Phage Libraries: Peptides Censored in Sequencing
Matochko, W. L., & Derda, R. (2013) · Computational and Mathematical Methods in Medicine · doi:10.1155/2013/491612 · Cited by 20
Discovery and characterization of new transcripts from RNA-seq data in mouse CD4+ T cells
Hutchins, A. P., Poulain, S., Fujii, H., & Miranda‐Saavedra, D. (2012) · Genomics · doi:10.1016/j.ygeno.2012.07.014 · Cited by 20
Accurate Estimation of Expression Levels of Homologous Genes in RNA-seq Experiments
Paşaniuc, B., Zaitlen, N., & Halperin, E. (2010) · Lecture notes in computer science · doi:10.1007/978-3-642-12683-3_26 · Cited by 20
ORMAN: Optimal resolution of ambiguous RNA-Seq multimappings in the presence of novel isoforms
Dao, P., Numanagić, I., Lin, Y., Hach, F., Karakoç, E., Donmez, N., Collins, C. C., Eichler, E. E., & Şahinalp, S. C. (2013) · Bioinformatics · doi:10.1093/bioinformatics/btt591 · Cited by 20
Optimization of sample preparation for culture-independent sequencing of Bordetella pertussis
Fong, W., Rockett, R. J., Timms, V. J., & Sintchenko, V. (2020) · Microbial Genomics · doi:10.1099/mgen.0.000332 · Cited by 20
“Sequencing resulted in variable human to pertussis read percentages (human reads made up 40–70 % of all reads); the cause of the variation could be due to GC bias of the sequencing method [21], which prioritizes”
BackgroundEvidence classification of high-throughput protocols and confidence integration in RegulonDB
Weiss, V., Medina-Rivera, A., Huerta, A. M., Santos-Zavaleta, A., Salgado, H., Morett, E., & Collado‐Vides, J. (2013) · Database · doi:10.1093/database/bas059 · Cited by 20
“In addition, systematic variations between experimental conditions, such as sample handling, or biases introduced during labelling or amplification steps, such as a GC bias, give rise to false positives at the peak-calling step (31,68,73,74).”
BackgroundUra, H., Togi, S., & Niida, Y. (2020) · International Journal of Molecular Sciences · doi:10.3390/ijms21103530 · Cited by 19
Metadata
- Authors
- Dohm, J. C., Lottaz, C., Borodina, T., & Himmelbauer, H.
- Affiliations
- Max Planck Institute for Molecular Genetics (DE)
- University of Regensburg (DE)
- Max Planck Society (DE)
- Corresponding author
- Himmelbauer, Heinz
- Venue
- Nucleic Acids Research
- Publisher
- Oxford University Press (OUP)
- Published
- 2008-07-26
- Volume
- 36
- Issue
- 16
- Pages
- e105-e105
- ISSN
- 0305-1048 (ISSN-L)
- 1362-4962
- PMC
- PMC2532726
- OpenAlex
- W2131088968
- Cited by
- 1,088
- References
- 22
- Citations by year
- 2026: 14 · 2025: 18 · 2024: 17 · 2023: 20 · 2022: 36 · 2021: 40 · 2020: 46 · 2019: 52 · 2018: 45 · 2017: 70 · 2016: 69 · 2015: 76 · 2014: 104 · 2013: 109 · 2012: 100
- FWCI
- 37.26
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- Nucleic Acids Research (publishedVersion, cc-by-nc)
- PubMed Central (publishedVersion, cc-by-nc)
- PubMed (publishedVersion)
- University of Regensburg Publication Server (University of Regensburg) (acceptedVersion)
- Max Planck Institute for Plasma Physics (submittedVersion)
- University of Regensburg Publication Server (University of Regensburg)
- Funders
- Max-Planck-Gesellschaft
- Topics
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Genomics and Phylogenetic Studies
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Fractal and DNA sequence analysis
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Gene expression and cancer classification
- Keywords
- sequencing error rate, insertion and deletion errors, GC content, resequencing, Beta vulgaris, de novo sequencing, single nucleotide polymorphisms, gene expression profiling
- MeSH terms
- Base Composition, DNA, Software, Helicobacter, Sequence Deletion, Sequence Analysis, DNA, Beta vulgaris
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.