Substantial biases in ultra-short read data sets from high-throughput DNA sequencing
Open accessThe DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Abstract
Novel sequencing technologies permit the rapid production of large sequence data sets. These technologies are likely to revolutionize genetics and biomedical research, but a thorough characterization of the ultra-short read output is necessary. We generated and analyzed two Illumina 1G ultra-short read data sets, i.e. 2.8 million 27mer reads from a Beta vulgaris genomic clone and 12.3 million 36mers from the Helicobacter acinonychis genome. We found that error rates range from 0.3% at the beginning of reads to 3.8% at the end of reads. Wrong base calls are frequently preceded by base G. Base substitution error frequencies vary by 10- to 11-fold, with A > C transversion being among the most frequent and C > G transversions among the least frequent substitution errors. Insertions and deletions of single bases occur at very low rates. When simulating re-sequencing we found a 20-fold sequencing coverage to be sufficient to compensate errors by correct reads. The read coverage of the sequenced regions is biased; the highest read density was found in intervals with elevated GC content. High Solexa quality scores are over-optimistic and low scores underestimate the data quality. Our results show different types of biases and ways to detect them. Such biases have implications on the use and interpretation of Solexa data, for de novo sequencing, re-sequencing, the identification of single nucleotide polymorphisms and DNA methylation sites, as well as for transcriptome analysis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures









Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“RNA-Seq is well known to suffer reproducible several fold biases in the number of DNA sequence reads obtained for different GC content genomic regions (Cheung et al., 2011; Dohm et al., 2008)”
From System wide analyses have underestimated protein abundances and the importance of transcription in mammals (2014) · cites this paper as Dohm et al., 2008
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
DNA sequencing with chain-terminating inhibitors
Sanger, F., Nicklen, S., & Coulson, A. R. (1977) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.74.12.5463 · Cited by 68,572 · cited 1×
“These technologies allow sequence determination much quicker and cheaper than the dideoxy chain terminator method presented by Sanger in 1977 (2).”
MethodGenome sequencing in microfabricated high-density picolitre reactors
Margulies, M., Egholm, M., Altman, W. E., Attiya, S., Bader, J. S., Bemben, L. A., Berka, J., Braverman, M. S., Chen, Y.-J., Chen, Z., et al. (2005) · Nature · doi:10.1038/nature03959 · Cited by 7,693
High-Resolution Profiling of Histone Methylations in the Human Genome
Barski, A., Cuddapah, S., Cui, K., Roh, T.-Y., Schones, D. E., Wang, Z., Wei, G., Chepelev, I., & Zhao, K. (2007) · Cell · doi:10.1016/j.cell.2007.05.009 · Cited by 6,845 · cited 1×
“For the human genome, ultra-short reads were applied in studies on chromatin analysis (11,12).”
MethodSpecific Enzymatic Amplification of DNA In Vitro: The Polymerase Chain Reaction
Mullis, K., Faloona, F., Scharf, S., Saiki, R., Horn, G., & Erlich, H. (1986) · Cold Spring Harbor Symposia on Quantitative Biology · doi:10.1101/sqb.1986.051.01.032 · Cited by 3,558 · cited 1×
“The adoption of high-throughput sequencing will revolutionize molecular biology research, similar to the invention of the polymerase chain reaction (PCR) twenty years ago (3).”
MethodShotgun bisulphite sequencing of the Arabidopsis genome reveals DNA methylation patterning
Cokus, S. J., Feng, S., Zhang, X., Chen, Z., Merriman, B., Haudenschild, C. D., Pradhan, S., Nelson, S. F., Pellegrini, M., & Jacobsen, S. E. (2008) · Nature · doi:10.1038/nature06745 · Cited by 2,256 · cited 1×
“In the context of DNA methylation site detection by shotgun bisulfite sequencing (21), the frequency of erroneous detection of C instead of T and vice versa is of particular interest.”
BackgroundRobertson, G., Hirst, M., Bainbridge, M., Bilenky, M., Zhao, Y., Zeng, T., Euskirchen, G., Bernier, B., Varhol, R., Delaney, A., et al. (2007) · Nature Methods · doi:10.1038/nmeth1068 · Cited by 1,454 · cited 1×
“For the human genome, ultra-short reads were applied in studies on chromatin analysis (11,12).”
MethodAccuracy and quality of massively parallel DNA pyrosequencing
Huse, S. M., Huber, J. A., Morrison, H. G., Sogin, M. L., & Welch, D. M. (2007) · Genome Biology · doi:10.1186/gb-2007-8-7-r143 · Cited by 1,282 · cited 3×
“(13) estimated that 39% of all errors that had passed GS20 quality filtering occur in homopolymer length detection.”
BackgroundWhole-genome sequencing and variant discovery in C. elegans
Hillier, L. W., Marth, G. T., Quinlan, A. R., Dooling, D., Fewell, G., Barnett, D., Fox, P., Glasscock, J. I., Hickenbotham, M., Huang, W., et al. (2008) · Nature Methods · doi:10.1038/nmeth.1179 · Cited by 404
Gene discovery and annotation using LCM-454 transcriptome sequencing
Emrich, S. J., Barbazuk, W. B., Li, L., & Schnable, P. S. (2007) · Genome Research · doi:10.1101/gr.5145806 · Cited by 381
Sampling the Arabidopsis Transcriptome with Massively Parallel Pyrosequencing
Weber, A. P. M., Weber, K. L., Carr, K., Wilkerson, C., & Ohlrogge, J. B. (2007) · Plant Physiology · doi:10.1104/pp.107.096677 · Cited by 366
Cited by
Items 201–300 of 1,001
Detecting false-positive signals in exome sequencing
Fuentes Fajardo, K. V., Adams, D., Program, N. C. S., Mason, C. E., Sincan, M., Tifft, C., Toro, C., Boerkoel, C. F., Gahl, W., & Markello, T. (2012) · Human Mutation · doi:10.1002/humu.22033 · Cited by 159
“…of short reads, loss of synchrony among DNA sequencing reactions within a cluster [Ledergerber and Dessimoz, 2011], or manufacturer/platform-specific mechanistic problems such as overlap in absorption spectra for guanine and thymine in the Illumina system [Dohm et al., 2008; Meacham et al., 2011].”
BackgroundMicrobial phylogenetic profiling with the Pacific Biosciences sequencing platform
Fichot, E. B., & Norman, R. S. (2013) · Microbiome · doi:10.1186/2049-2618-1-10 · Cited by 159
A Wide Extent of Inter-Strain Diversity in Virulent and Vaccine Strains of Alphaherpesviruses
Szpara, M. L., Tafuri, Y. R., Parsons, L., Shamim, S. R., Verstrepen, K. J., Legendre, M., & Enquist, L. W. (2011) · PLoS Pathogens · doi:10.1371/journal.ppat.1002282 · Cited by 157
“low G/C content, as has been observed for both eukaryotic and bacterial genomes (Figure S2A,B in Text S1) [59,60].”
BackgroundIVT-seq reveals extreme bias in RNA sequencing
Lahens, N. F., Kavakli, I. H., Zhang, R., Hayer, K., Black, M. B., Dueck, H., Pizarro, A., Kim, J., Irizarry, R., Thomas, R. S., et al. (2014) · Genome Biology · doi:10.1186/gb-2014-15-6-r86 · Cited by 158
Quantitative miRNA expression analysis: comparing microarrays with next-generation sequencing
Willenbrock, H., Salomon, J., Søkilde, R., Barken, K. B., Hansen, T. N., Nielsen, F. C., Møller, S., & Litman, T. (2009) · RNA · doi:10.1261/rna.1699809 · Cited by 158
“This is in line with the previously reported sequence read variation issue on the Illumina sequencing platform (Dohm et al. 2008).”
ResultRazerS 3: Faster, fully sensitive read mapping
Weese, D., Holtgrewe, M., & Reinert, K. (2012) · Bioinformatics · doi:10.1093/bioinformatics/bts505 · Cited by 158
“In a recent publication, Li and Homer (2010) give a survey and categorize the existing tools into approaches using a q-gram index for a seed-and-extend strategy (e.”
BackgroundReptile: representative tiling for short read error correction
Yang, X., Dorman, K. S., & Aluru, S. (2010) · Bioinformatics · doi:10.1093/bioinformatics/btq468 · Cited by 158
Li, J. J., Jiang, C.-R., Brown, J. B., Huang, H., & Bickel, P. J. (2011) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1113972108 · Cited by 141
Melo, A., Bartaula, R., & Hale, I. L. (2016) · BMC Bioinformatics · doi:10.1186/s12859-016-0879-y · Cited by 158
Estimating genotype error rates from high-coverage next-generation sequence data
Wall, J. D., Tang, L. F., Zerbe, B., Kvale, M. N., Kwok, P.-Y., Schaefer, C., & Risch, N. (2014) · Genome Research · doi:10.1101/gr.168393.113 · Cited by 140
“…have identified several systematic sources of error in IL sequencing data, including higher error rates near the end of reads (Kircher et al. 2009), higher error rates in GC-rich regions (Dohm et al. 2008), and specific sequence motifs associated with high error rates (Nakamura et al. 2011).”
BackgroundDrug discovery in advanced prostate cancer: translating biology into therapy
Yap, T. A., Smith, A. D., Ferraldeschi, R., Al‐Lazikani, B., Workman, P., & Bono, J. S. D. (2016) · Nature Reviews Drug Discovery · doi:10.1038/nrd.2016.120 · Cited by 157
Jaffe, A. E., Shin, J., Collado-Torres, L., Leek, J. T., Tao, R., Li, C., Gao, Y., Jia, Y., Maher, B. J., Hyde, T. M., et al. (2015) · Nature Neuroscience · doi:10.1038/nn.3898 · Cited by 156
Using metagenomics to investigate human and environmental resistomes
Bengtsson-Palme, J., Larsson, D. G. J., & Kristiansson, E. (2017) · Journal of Antimicrobial Chemotherapy · doi:10.1093/jac/dkx199 · Cited by 134
Multi-perspective quality control of Illumina RNA sequencing data analysis
Sheng, Q., Vickers, K. C., Zhao, S., Wang, J., Samuels, D. C., Koues, O. I., Shyr, Y., & Guo, Y. P. (2016) · Briefings in Functional Genomics · doi:10.1093/bfgp/elw035 · Cited by 155
Large-scale detection and analysis of RNA editing in grape mtDNA by RNA deep-sequencing
Picardi, E., Horner, D. S., Chiara, M., Schiavon, R., Valle, G., & Pesole, G. (2010) · Nucleic Acids Research · doi:10.1093/nar/gkq202 · Cited by 154
“In particular, G-to-U, C-to-A substitutions appeared overrepresented by Solexa/Illumina reads with respect to SOLiD data, likely reflecting typical miscalls of Solexa/ Illumina reads (37).”
MethodBenchmarking of long-read correction methods
Dohm, J. C., Peters, P., Stralis‐Pavese, N., & Himmelbauer, H. (2020) · NAR Genomics and Bioinformatics · doi:10.1093/nargab/lqaa037 · Cited by 154
“…error rates are expected whenever a single molecule is sequenced, in contrast to highly parallel short-read sequencing where local clusters of the same molecule are sequenced simultaneously, compensating for individual errors or out-of-phase templates and achieving very low error rates (11,12).”
Self-citationReciprocal intronic and exonic histone modification regions in humans
Huff, J. T., Plocik, A. M., Guthrie, C., & Yamamoto, K. R. (2010) · Nature Structural & Molecular Biology · doi:10.1038/nsmb.1924 · Cited by 130
From next-generation resequencing reads to a high-quality variant data set
Pfeifer, S. P. (2016) · Heredity · doi:10.1038/hdy.2016.102 · Cited by 152
“These biases can originate from the experimental sample preparation, where, in addition to unintentional contamination, polymerases frequently introduce errors in fragments because of imperfect in vitro ampli fi cation (Dohm et al. , 2008).”
BackgroundNew Virologic Tools for Management of Chronic Hepatitis B and C
Chevaliez, S., Rodriguez, C., & Pawlotsky, J. (2012) · Gastroenterology · doi:10.1053/j.gastro.2012.02.027 · Cited by 151
Whole genome sequencing of a single Bos taurusanimal for single nucleotide polymorphism discovery
Eck, S. H., Benet‐Pagès, A., Flisikowski, K., Meitinger, T., Fries, R., & Strom, T. M. (2009) · Genome biology · doi:10.1186/gb-2009-10-8-r82 · Cited by 150
“Part of this over-dispersion can be accounted for by the dependence of the read depth on the GCcontent, which had a maximum average read depth at approximately 57% GC-content (Figure 1b) [9,12].”
BackgroundQuality filtering of Illumina index reads mitigates sample cross-talk
Wright, E. S., & Vetsigian, K. (2016) · BMC Genomics · doi:10.1186/s12864-016-3217-x · Cited by 148
“Substitutions, where one base is misread as another, are the most frequent error class and occur more often toward the end of the sequence [2, 3].”
BackgroundJiang, B., Liang, X., Chen, Y., Ma, T., Liu, L., Li, J., Jiang, R., Chen, T., Zhang, X., & Li, S. (2012) · Scientific Reports · doi:10.1038/srep00936 · Cited by 149
Brueggeman, A. J., Gangadharaiah, D. S., Cserhati, M. F., Casero, D., Weeks, D. P., & Ladunga, I. (2012) · The Plant Cell · doi:10.1105/tpc.111.093435 · Cited by 147
“Such biases include sequencing reads that match imperfectly to the genome or the transcriptome (Li et al., 2010), amplification, and sequencing biases (Dohm et al., 2008).”
Alignment of Next-Generation Sequencing Reads
Reinert, K., Langmead, B., Weese, D., & Evers, D. J. (2015) · Annual Review of Genomics and Human Genetics · doi:10.1146/annurev-genom-090413-025358 · Cited by 147
Bias in RNA‐seq Library Preparation: Current Challenges and Solutions
Shi, H., Zhou, Y., Jia, E., Pan, M., Bai, Y., & Ge, Q. (2021) · BioMed Research International · doi:10.1155/2021/6647597 · Cited by 145
“It is due to the fact that PCR amplification stochastically introduces biases, which can propagate to later cycles [2].”
BackgroundCollins, S. C., Bray, S. M., Suhl, J. A., Cutler, D. J., Coffee, B., Zwick, M. E., & Warren, S. T. (2010) · American Journal of Medical Genetics Part A · doi:10.1002/ajmg.a.33626 · Cited by 117
“2010 Wiley-Liss, Inc. Key words: FMR1;massively parallel sequencing; developmental delay”
Sevim, V., Lee, J., Egan, R., Clum, A., Hundley, H. N., Lee, J., Everroad, R. C., Detweiler, A. M., Bebout, B. M., Pett‐Ridge, J., et al. (2019) · Scientific Data · doi:10.1038/s41597-019-0287-z · Cited by 143
Fan, H. C., & Quake, S. R. (2010) · PLoS ONE · doi:10.1371/journal.pone.0010439 · Cited by 141
“Others have shown the existence of substantial GC bias in Illumina/Solexa and ABI/ SOLiD sequencing [5,8,9,10], and this limits the sensitivity of the detection of under- or over-representation of chromosomes.”
BackgroundUltrasensitive detection of rare mutations using next-generation targeted resequencing
Flaherty, P., Natsoulis, G., Muralidharan, O., Winters, M. A., Buenrostro, J. D., Bell, J., Brown, S. T., Holodniy, M., Zhang, N. R., & Ji, H. P. (2011) · Nucleic Acids Research · doi:10.1093/nar/gkr861 · Cited by 140
“(16) who found that bases preceded by G have a high error rate.”
BackgroundChiu, R. W. K., Sun, H., Akolekar, R., Clouser, C. R., Lee, C. C., McKernan, K. J., Zhou, D., Nicolaides, K. H., & Lo, Y. M. D. (2009) · Clinical Chemistry · doi:10.1373/clinchem.2009.136507 · Cited by 139
Gerlach, W., Jünemann, S., Tille, F., Goesmann, A., & Stoye, J. (2009) · BMC Bioinformatics · doi:10.1186/1471-2105-10-430 · Cited by 139
“It is known that some sequencing techniques exhibit correlations between read coverage and GC content [36-38].”
Allentoft, M. E., Schuster, S. C., Holdaway, R. N., Hale, M. L., McLay, E., Oskam, C. L., Gilbert, M. T. P., Spencer, P. B. S., Willerslev, E., & Bunce, M. (2009) · BioTechniques · doi:10.2144/000113086 · Cited by 138
Metagenomics Using Next-Generation Sequencing
Bragg, L. M., & Tyson, G. W. (2014) · Methods in molecular biology · doi:10.1007/978-1-62703-712-9_15 · Cited by 138
Probabilistic error correction for RNA sequencing
Le, H.-S., Schulz, M. H., McCauley, B. S., Hinman, V. F., & Bar‐Joseph, Z. (2013) · Nucleic Acids Research · doi:10.1093/nar/gkt215 · Cited by 138
“For example, error rates of up to 3.8% were observed when using Illumina’s GenomeAnalyzer (17).”
InfluentialCirculating Nucleic Acids in Plasma and Serum: Recent Developments
Gahan, P. B., & Swaminathan, R. (2008) · Annals of the New York Academy of Sciences · doi:10.1196/annals.1448.050 · Cited by 121
McElhoe, J. A., Holland, M. M., Makova, K. D., Su, M. S., Paul, I. M., Baker, C. H., Faith, S. A., & Young, B. A. (2014) · Forensic Science International Genetics · doi:10.1016/j.fsigen.2014.05.007 · Cited by 136
“This type of error has been reported in other sequencing studies using Illumina’s Genome Analyzer [36,39,40], which employs the same SBS chemistry as the MiSeq.”
MethodKellar, P. R., Hertweck, K. L., Mayfield, D. R., McKain, M. R., Leebens‐Mack, J., & Pires, J. C. (2012) · American Journal of Botany · doi:10.3732/ajb.1100491 · Cited by 135
“…contains biases (e.g., caused by hexamer binding, Hansen et al., 2010 ) and types of error (e.g., frequencies of incorrect base pair calls, Dohm et al., 2008 ) that can inhibit robust reconstructions of genomic sequences, especially in organisms with large genomes ( Schatz et al., 2010 ).”
BackgroundMethods to improve the accuracy of next-generation sequencing
Cheng, C., Fei, Z., & Xiao, P. (2023) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2023.982111 · Cited by 134
“It can fully address the issue in homopolymer sequencing, though a tendency towards substitution errors in the AT-rich regions and CG-rich regions exists (Dohm et al., 2008; Harismendy et al., 2009; Minoche et al., 2011; Nakamura et al., 2011).”
BackgroundBallenghien, M., Faivre, N., & Galtier, N. (2017) · BMC Biology · doi:10.1186/s12915-017-0366-6 · Cited by 132
“This is consistent with documented error biases of the Illumina technology [42, 43].”
ResultImpact of Chromatin Structures on DNA Processing for Genomic Analyses
Teytelman, L., Özaydın, B., Zill, O., Lefrançois, P., Snyder, M., Rine, J., & Eisen, M. B. (2009) · PLoS ONE · doi:10.1371/journal.pone.0006700 · Cited by 116
Normalization of ChIP-seq data with control
Liang, K., & Keleş, S. (2012) · BMC Bioinformatics · doi:10.1186/1471-2105-13-199 · Cited by 112
“Many follow-up studies have shown that the distribution of reads is far from uniform and is affected by many factors, including GC content (Dohm et al. 2008; Kuan et al. 2011), mappability (Rozowsky et al. 2009), chromatin structure, and copy number variation (Vega et al. 2009), among others.”
BackgroundBarcoding bias in high-throughput multiplex sequencing of miRNA
Alon, S., Vigneault, F., Eminaga, S., Christodoulou, D. C., Seidman, J. G., Church, G. M., & Eisenberg, E. (2011) · Genome Research · doi:10.1101/gr.121715.111 · Cited by 114
“2009) to preferences to specific sequence mutations (Dohm et al. 2008) up to problems caused by the wrong alignment of miRNA sequences (de Hoon”
BackgroundDiscovery of barley miRNAs through deep sequencing of short reads
SCHREIBER, A. W., Shi, B., Huang, C.-Y., Langridge, P., & Baumann, U. (2011) · BMC Genomics · doi:10.1186/1471-2164-12-129 · Cited by 127
Chromatin profiling by directly sequencing small quantities of immunoprecipitated DNA
Goren, A., Ozsolak, F., Shoresh, N., Ku, M., Adli, M., Hart, C., Gymrek, M., Zuk, O., Regev, A., Milos, P. M., et al. (2010) · Nature Methods · doi:10.1038/nmeth.1404 · Cited by 118
A Complete Mitochondrial Genome Sequence from a Mesolithic Wild Aurochs (Bos primigenius)
Edwards, C. J., Magee, D. A., Park, S. D. E., McGettigan, P. A., Lohan, A. J., Murphy, A., Finlay, E. K., Shapiro, B., Chamberlain, A. T., Richards, M. B., et al. (2010) · PLoS ONE · doi:10.1371/journal.pone.0009255 · Cited by 101
“sequencing errors, has previously been described as being inherent to the Illumina GA sequencing technology [46].”
Review of massively parallel DNA sequencing technologies
Moorthie, S. A., Mattocks, C., & Wright, C. F. (2011) · The HUGO Journal · doi:10.1007/s11568-011-9156-3 · Cited by 123
Metagenomic exploration of antibiotic resistance in soil
Monier, J.-M., Demanèche, S., Delmont, T. O., Mathieu, A., Vogel, T. M., & Simonet, P. (2011) · Current Opinion in Microbiology · doi:10.1016/j.mib.2011.04.010 · Cited by 122
“So despite some biases [36], estimates of ARGD abundance in various environments can be determined.”
BackgroundSequencing platform and library preparation choices impact viral metagenomes
Solonenko, S. A., Ignacio‐Espinoza, J. C., Alberti, A., Cruaud, C., Hallam, S., Konstantinidis, K., Tyson, G. W., Wincker, P., & Sullivan, M. B. (2013) · BMC Genomics · doi:10.1186/1471-2164-14-320 · Cited by 122
“In contrast, because Illumina errors are localized to particular parts of a read [47,48], these data were trimmed using a threshold predicted quality score to remove suspect regions of the read at both the 3 ’ and 5 ’ ends using DynamicTrim.pl, part of the SolexaQA package [49] (Additional file 1:…”
Next-generation sequencing: recent applications to the analysis of colorectal cancer
Vecchio, F. D., Mastroiaco, V., Marco, A. D., Compagnoni, C., Capece, D., Zazzeroni, F., Capalbo, C., Alesse, E., & Tessitore, A. (2017) · Journal of Translational Medicine · doi:10.1186/s12967-017-1353-y · Cited by 120
DNA Mini-Barcoding: A Derived Barcoding Method for Herbal Molecular Identification
Gao, Z., Liu, Y., Wang, X., Wei, X., & Han, J. (2019) · Frontiers in Plant Science · doi:10.3389/fpls.2019.00987 · Cited by 121
Overcoming bias and systematic errors in next generation sequencing data
Taub, M. A., Bravo, H. C., & Irizarry, R. A. (2010) · Genome Medicine · doi:10.1186/gm208 · Cited by 120
“Focusing on the Illumina Genome Analyzer platform, base-call errors are not randomly distributed across the cycle positions in sequenced reads [12].”
Accurate detection and genotyping of SNPs utilizing population sequencing data
Bansal, V., Harismendy, O., Tewhey, R., Murray, S. S., Schork, N. J., Topol, E. J., & Frazer, K. A. (2010) · Genome Research · doi:10.1101/gr.100040.109 · Cited by 109
“(Dohm et al. 2008; Erlich et al. 2008).”
Probabilistic base calling of Solexa sequencing data
Rougemont, J., Amzallag, A., Iseli, C., Farinelli, L., Xenarios, I., & Naef, F. (2008) · BMC Bioinformatics · doi:10.1186/1471-2105-9-431 · Cited by 99
Miyamoto, M., Motooka, D., Gotoh, K., Imai, T., Yoshitake, K., Goto, N., Iida, T., Yasunaga, T., Horii, T., Arakawa, K., et al. (2014) · BMC Genomics · doi:10.1186/1471-2164-15-699 · Cited by 117
“The Illumina MiSeq (MiSeq) benchtop se-quencer became available at the end of 2011 and employs the same sequencing-by-synthesis technology [3,4] as the Illumina GAII and HiSeq sequencers.”
Buschmann, D., Haberberger, A., Kirchner, B., Spornraft, M., Riedmaier, I., Schelling, G., & Pfaffl, M. W. (2016) · Nucleic Acids Research · doi:10.1093/nar/gkw545 · Cited by 103
“It is well-known that miscalls on the Illumina platform occur more frequently in GC-rich regions and increase in later cycles (141).”
BackgroundInfluentialLeonard, A. S., McClain, M. T., Smith, G. J. D., Wentworth, D. E., Halpin, R., Lin, X., Ransier, A., Stockwell, T. B., Das, S. R., Gilbert, A. S., et al. (2016) · Journal of Virology · doi:10.1128/jvi.01657-16 · Cited by 115
“Based on the known error rate of the Illumina sequencing platform (36, 37) and the stringency of these variant call criteria, we used a minimum allele frequency cutoff of 1% to identify variants.”
MethodDARIO: a ncRNA detection and analysis tool for next-generation sequencing experiments
Fasold, M., Langenberger, D., Binder, H., Stadler, P. F., & Hoffmann, S. (2011) · Nucleic Acids Research · doi:10.1093/nar/gkr357 · Cited by 114
A Statistical Framework for the Analysis of ChIP-Seq Data
Kuan, P. F., Chung, D., Pan, G., Thomson, J. A., Stewart, R., & Keleş, S. (2011) · Journal of the American Statistical Association · doi:10.1198/jasa.2011.ap09706 · Cited by 100
“In addition to the mappability bias, observed tag counts tend to correlate with GC content (Dohm et al. 2008).”
BackgroundSu, C.-L., Chao, Y., Chang, Y. A., Chen, W., Chen, C., Lee, A.-Y., Hwa, K. T., & Shih, M. (2011) · Plant and Cell Physiology · doi:10.1093/pcp/pcr097 · Cited by 114
SNP discovery by high-throughput sequencing in soybean
Wu, X., Ren, C., Joshi, T., Vuong, T. D., Xu, D. H., & Nguyen, H. T. (2010) · BMC Genomics · doi:10.1186/1471-2164-11-469 · Cited by 113
“However, we did not observe a correlation between GC content and read coverage, which is known to be present in Solexa sequencing DNA samples prepared by nebulization or sonication [25].”
BackgroundJerome, J. P., Bell, J. A., Plovanich‐Jones, A. E., Barrick, J. E., Brown, C. T., & Mansfield, L. S. (2011) · PLoS ONE · doi:10.1371/journal.pone.0016399 · Cited by 114
“shown by others [26], suggesting that indel mutation analysis is”
BackgroundA comparative analysis of algorithms for somatic SNV detection in cancer
Roberts, N. D., Kortschak, R. D., Parker, W. T., SCHREIBER, A. W., Branford, S., Scott, H. S., Glonek, G., & Adelson, D. L. (2013) · Bioinformatics · doi:10.1093/bioinformatics/btt375 · Cited by 112
“Received on March 25, 2013; revised on May 31, 2013; accepted on June 24, 2013”
BackgroundIvakhno, S., Royce, T., Cox, A. J., Evers, D. J., Cheetham, R. K., & Tavaré, S. (2010) · Bioinformatics · doi:10.1093/bioinformatics/btq587 · Cited by 111
A new approach for detecting low-level mutations in next-generation sequence data
Li, M., & Stoneking, M. (2012) · Genome biology · doi:10.1186/gb-2012-13-5-r34 · Cited by 109
“Moreover, sequencing error is unevenly distributed along the genome and may be influenced by the sequence context, position on the read, and molecule structure, resulting in sequencing error ‘hot spots’ where the error rate can be ten-fold greater (or more) than the genome average [3,7-10].”
BackgroundHigh quality draft sequences for prokaryotic genomes using a mix of new sequencing technologies
Aury, J.-M., Cruaud, C., Barbe, V., Rogier, O., Mangenot, S., Samson, G., Poulain, J., Anthouard, V., Scarpelli, C., Artiguenave, F., et al. (2008) · BMC Genomics · doi:10.1186/1471-2164-9-603 · Cited by 92
“As previously reported, errors consist mainly (98.8% in our data set) of mismatches (e.g. bases called as another base) [15-17].”
BackgroundInfluentialVavouri, T., & Lehner, B. (2011) · PLoS Genetics · doi:10.1371/journal.pgen.1002036 · Cited by 95
“This is not accounted for by the known GC-bias of Solexa sequencing [50] (Figure 1D, Pearson correlation = 0.”
BackgroundKawaji, H., Lizio, M., Itoh, M., Kanamori-Katayama, M., Kaiho, A., Nishiyori-Sueki, H., Shin, J. W., Kojima-Ishiyama, M., Kawano, M., Murata, M., et al. (2014) · Genome Research · doi:10.1101/gr.156232.113 · Cited by 109
“First, we asked if GC content could introduce any differences since it is reported that PCR amplification efficiency depends on GC content (Kozarewa et al. 2009) and elevated error rates occur in GC-rich sequences on the Illumina platform (Dohm et al. 2008; Nakamura et al. 2011).”
BackgroundComparison of Sequencing Platforms for Single Nucleotide Variant Calls in a Human Sample
Ratan, A., Miller, W., Guillory, J., Stinson, J., Seshagiri, S., & Schuster, S. C. (2013) · PLoS ONE · doi:10.1371/journal.pone.0055089 · Cited by 93
“With the introduction of these technologies, reports of biases in all platforms [13], as well as”
MethodComparison of mapping algorithms used in high-throughput sequencing: application to Ion Torrent data
Caboche, S., Audebert, C., Lemoine, Y., & Hot, D. (2014) · BMC Genomics · doi:10.1186/1471-2164-15-264 · Cited by 97
Quinn, T. P., Crowley, T. M., & Richardson, M. F. (2018) · BMC Bioinformatics · doi:10.1186/s12859-018-2261-8 · Cited by 93
“In addition, RNA-Seq has two notable sources of bias that an analyst may need to address: transcripts with longer lengths [4] and higher GC content [5] have their relative abundances over-estimated.”
BackgroundEstimation of sequencing error rates in short reads
Wang, V., Blades, N. J., Ding, J., Sultana, R., & Parmigiani, G. (2012) · BMC Bioinformatics · doi:10.1186/1471-2105-13-185 · Cited by 108
“[7,8] for the Illumina platform, and Huse et al.”
BackgroundMethodLibrary preparation for highly accurate population sequencing of RNA viruses
Acevedo, A., & Andino, R. (2014) · Nature Protocols · doi:10.1038/nprot.2014.118 · Cited by 107
Copy number variation in the speciation of pigs: a possible prominent role for olfactory receptors
Paudel, Y., Madsen, O., Megens, H., Frantz, L., Bosse, M., Crooijmans, R. P. M. A., & Groenen, M. A. M. (2015) · BMC Genomics · doi:10.1186/s12864-015-1449-9 · Cited by 107
“Next generation sequencing methods have been shown biased in coverage in regions of high or low GC [53-58].”
Pais, T. M., Foulquié-Moreno, M. R., Hubmann, G., Duitama, J., Swinnen, S., Goovaerts, A., Yang, Y., Dumortier, F. M., & Thevelein, J. M. (2013) · PLoS Genetics · doi:10.1371/journal.pgen.1003548 · Cited by 107
“The coverage of at least 20 times was based on previous findings that a 20-fold sequencing coverage is sufficient to compensate for errors by the number of correct reads [23].”
BackgroundDetecting Selective Sweeps from Pooled Next-Generation Sequencing Samples
Boitard, S., Schlötterer, C., Nolte, V., Pandey, R. V., & Futschik, A. (2012) · Molecular Biology and Evolution · doi:10.1093/molbev/mss090 · Cited by 107
“This observation is consistent with previous results (Dohm et al. 2008), showing that Illumina scores tend to be too pessimistic.”
BackgroundResultUsing non-uniform read distribution models to improve isoform expression inference in RNA-Seq
Wu, Z., Wang, X., & Zhang, X. (2011) · Bioinformatics · doi:10.1093/bioinformatics/btq696 · Cited by 98
Detection and Removal of Biases in the Analysis of Next-Generation Sequencing Reads
Schwartz, S., Oren, R., & Ast, G. (2011) · PLoS ONE · doi:10.1371/journal.pone.0016685 · Cited by 102
“Several studies have found that GC content correlates positively with read coverage [14,15].”
BackgroundAnalysis of the genetic diversity of influenza A viruses using next-generation DNA sequencing
den Hoecke, S. V., Verhelst, J., Vuylsteke, M., & Saelens, X. (2015) · BMC Genomics · doi:10.1186/s12864-015-1284-z · Cited by 106
“It is known that Illumina MiSeq and Ion Torrent PGM sequencers perform rather poorly when sequencing DNA with very low or very high GC content, which leads to low sequencing coverage of AT and GC rich regions [33,34].”
BackgroundWang, C., Han, J., Liu, C., Kibet, K. N., Kayesh, E., Shangguan, L., Li, X., & Fang, J. (2012) · BMC Genomics · doi:10.1186/1471-2164-13-122 · Cited by 106
“Reverse transcription, amplification or sequencing could also be a cause of some of the nucleotide divergence observed [31].”
BackgroundIMSEQ—a fast and error aware approach to immunogenetic sequence analysis
Kuchenbecker, L., Nienen, M., Hecht, J., Neumann, A. U., Babel, N., Reinert, K., & Robinson, P. N. (2015) · Bioinformatics · doi:10.1093/bioinformatics/btv309 · Cited by 96
Next-generation sequencing technologies and their impact on microbial genomics
Forde, B. M., & O’Toole, P. W. (2013) · Briefings in Functional Genomics · doi:10.1093/bfgp/els062 · Cited by 105
“could affect downstream data analysis [134].”
Bioinformatics for NGS-based metagenomics and the application to biogas research
Jünemann, S., Kleinbölting, N., Jaenicke, S., Henke, C., Hassa, J., Nelkner, J., Stolze, Y., Albaum, S. P., Schlüter, A., Goesmann, A., et al. (2017) · Journal of Biotechnology · doi:10.1016/j.jbiotec.2017.08.012 · Cited by 106
Comparison of Sequence Reads Obtained from Three Next-Generation Sequencing Platforms
Suzuki, S., Ono, N., Furusawa, C., Ying, B., & Yomo, T. (2011) · PLoS ONE · doi:10.1371/journal.pone.0019534 · Cited by 104
“Since the Solexa base caller reports the quality of each base call as an estimated Quality Value (QV) similar to the phred score based on the image output [8], in order to filter out the affect of the errors due to these low quality base calls we trimmed the bases for which QV was lower than 0, and filtered out the tr…”
BackgroundMethodMica, E., Piccolo, V., Delledonne, M., Ferrarini, A., Pezzotti, M., Casati, C., Fabbro, C. D., Valle, G., Policriti, A., Morgante, M., et al. (2009) · BMC Genomics · doi:10.1186/1471-2164-10-558 · Cited by 104
“[31] observed a strong relationship between”
InfluentialPinto, M., Borges, V., Antelo, M., Pinheiro, M., Nunes, A., Azevedo, J., Borrego, M. J., Mendonça, J., Carpinteiro, D., Vieira, L., et al. (2016) · Nature Microbiology · doi:10.1038/nmicrobiol.2016.190 · Cited by 96
Incorporating sequence quality data into alignment improves DNA read mapping
Frith, M. C., Wan, R., & Horton, P. (2010) · Nucleic Acids Research · doi:10.1093/nar/gkq010 · Cited by 104
“Another consideration is that sequence quality data is not necessarily accurate: high quality scores can be over-optimistic (15).”
Saha, S., Hunter, W. B., Reese, J., Morgan, J. K., Marutani-Hert, M., Huang, H., & Lindeberg, M. (2012) · PLoS ONE · doi:10.1371/journal.pone.0050067 · Cited by 102
“The most likely reason for the low coverage is the previously demonstrated bias of next generation sequencing technologies for regions of DNA with higher GC content [35].”
BackgroundChung, D., Kuan, P. F., Li, B., Sanalkumar, R., Liang, K., Bresnick, E. H., Dewey, C., & Keleş, S. (2011) · PLoS Computational Biology · doi:10.1371/journal.pcbi.1002111 · Cited by 89
“as mappability [10] and GC content [45].”
Assessment of Fetal Sex Chromosome Aneuploidy Using Directed Cell-Free DNA Analysis
Nicolaides, K. H., Musci, T. J., Struble, C. A., Syngelaki, A., & Gil, M. M. (2013) · Fetal Diagnosis and Therapy · doi:10.1159/000357198 · Cited by 100
RepARK—de novo creation of repeat libraries from whole-genome NGS reads
Koch, P., Platzer, M., & Downie, B. (2014) · Nucleic Acids Research · doi:10.1093/nar/gku210 · Cited by 101
“Alternatively, real sequencing data are subjected to various technological biases leading to the underrepresentation of particular motifs (e.g. GC-rich or heterochromatin sequence, both regions of high repeat content (42)).”
BackgroundMethodGenome‐wide SNP detection in the great titParus majorusing high throughput sequencing
van Bers, N. E. M., van Oers, K., Kerstens, H. H. D., Dibbits, B. W., Crooijmans, R. P. M. A., Visser, M. E., & Groenen, M. A. M. (2010) · Molecular Ecology · doi:10.1111/j.1365-294x.2009.04486.x · Cited by 99
“Sequencing errors are often found in the last nucleotides of the sequence reads (Dohm et al. 2008).”
BackgroundJalan, N., Aritua, V., Kumar, D., Yu, F., Jones, J. B., Graham, J. H., Setúbal, J. C., & Wang, N. (2011) · Journal of Bacteriology · doi:10.1128/jb.05777-11 · Cited by 98
“Illumina data, on the other hand, have errors mainly due to mismatches (19).”
BackgroundTranscriptome assembly and isoform expression level estimation from biased RNA-Seq reads
Li, W., & Jiang, T. (2012) · Bioinformatics · doi:10.1093/bioinformatics/bts559 · Cited by 97
Zhan, B., Fadista, J., Thomsen, B., Hedegaard, J., Panitz, F., & Bendixen, C. (2011) · BMC Genomics · doi:10.1186/1471-2164-12-557 · Cited by 97
“The tools and pipelines applied here demonstrate that whole genome sequencing at relatively modest coverage levels is sufficient firstly, to survey sequence and structural variations by integrating different variation detection methods which minimized the false positive rate of polymorphism detection, a known problem…”
BackgroundCGAL: computing genome assembly likelihoods
Rahman, A., & Pachter, L. (2013) · Genome Biology · doi:10.1186/gb-2013-14-1-r8 · Cited by 85
A novel and well-defined benchmarking method for second generation read mapping
Holtgrewe, M., Emde, A., Weese, D., & Reinert, K. (2011) · BMC Bioinformatics · doi:10.1186/1471-2105-12-210 · Cited by 96
White, M. A., Kitano, J., & Peichel, C. L. (2015) · Molecular Biology and Evolution · doi:10.1093/molbev/msv078 · Cited by 96
“Short sequencing reads are subject to mapping biases (Dohm et al. 2008; Bullard et al. 2010), which could differentially affect the X chromosome or Y chromosome read counts.”
BackgroundWhittall, J. B., Syring, J. V., Parks, M., Buenrostro, J. D., DICK, C., Liston, A., & Cronn, R. (2010) · Molecular Ecology · doi:10.1111/j.1365-294x.2009.04474.x · Cited by 96
“Similarly, biases in genome-wide base composition have been reported to result in biases in sequencing error (Dohm et al. 2008; Dolan & Denver 2008).”
BackgroundStrand-specific deep sequencing of the transcriptome
Vivancos, A. P., Güell, M., Dohm, J. C., Serrano, L., & Himmelbauer, H. (2010) · Genome Research · doi:10.1101/gr.094318.109 · Cited by 96
Self-citationDeep sequencing of evolving pathogen populations: applications, errors, and bioinformatic solutions
McElroy, K., Thomas, T., & Luciani, F. (2014) · Microbial Informatics and Experimentation · doi:10.1186/2042-5783-4-1 · Cited by 95
“Error rates also increase along the length of a read, in some cases being ten fold higher at the 3′ end than the 5′ end [52].”
Background
Metadata
- Authors
- Dohm, J. C., Lottaz, C., Borodina, T., & Himmelbauer, H.
- Affiliations
- Max Planck Institute for Molecular Genetics (DE)
- University of Regensburg (DE)
- Max Planck Society (DE)
- Corresponding author
- Himmelbauer, Heinz
- Venue
- Nucleic Acids Research
- Publisher
- Oxford University Press (OUP)
- Published
- 2008-07-26
- Volume
- 36
- Issue
- 16
- Pages
- e105-e105
- ISSN
- 0305-1048 (ISSN-L)
- 1362-4962
- PMC
- PMC2532726
- OpenAlex
- W2131088968
- Cited by
- 1,088
- References
- 22
- Citations by year
- 2026: 14 · 2025: 18 · 2024: 17 · 2023: 20 · 2022: 36 · 2021: 40 · 2020: 46 · 2019: 52 · 2018: 45 · 2017: 70 · 2016: 69 · 2015: 76 · 2014: 104 · 2013: 109 · 2012: 100
- FWCI
- 37.26
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- Nucleic Acids Research (publishedVersion, cc-by-nc)
- PubMed Central (publishedVersion, cc-by-nc)
- PubMed (publishedVersion)
- University of Regensburg Publication Server (University of Regensburg) (acceptedVersion)
- Max Planck Institute for Plasma Physics (submittedVersion)
- University of Regensburg Publication Server (University of Regensburg)
- Funders
- Max-Planck-Gesellschaft
- Topics
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Genomics and Phylogenetic Studies
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Fractal and DNA sequence analysis
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Gene expression and cancer classification
- Keywords
- sequencing error rate, insertion and deletion errors, GC content, resequencing, Beta vulgaris, de novo sequencing, single nucleotide polymorphisms, gene expression profiling
- MeSH terms
- Base Composition, DNA, Software, Helicobacter, Sequence Deletion, Sequence Analysis, DNA, Beta vulgaris
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.