Substantial biases in ultra-short read data sets from high-throughput DNA sequencing
Open accessThe DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Abstract
Novel sequencing technologies permit the rapid production of large sequence data sets. These technologies are likely to revolutionize genetics and biomedical research, but a thorough characterization of the ultra-short read output is necessary. We generated and analyzed two Illumina 1G ultra-short read data sets, i.e. 2.8 million 27mer reads from a Beta vulgaris genomic clone and 12.3 million 36mers from the Helicobacter acinonychis genome. We found that error rates range from 0.3% at the beginning of reads to 3.8% at the end of reads. Wrong base calls are frequently preceded by base G. Base substitution error frequencies vary by 10- to 11-fold, with A > C transversion being among the most frequent and C > G transversions among the least frequent substitution errors. Insertions and deletions of single bases occur at very low rates. When simulating re-sequencing we found a 20-fold sequencing coverage to be sufficient to compensate errors by correct reads. The read coverage of the sequenced regions is biased; the highest read density was found in intervals with elevated GC content. High Solexa quality scores are over-optimistic and low scores underestimate the data quality. Our results show different types of biases and ways to detect them. Such biases have implications on the use and interpretation of Solexa data, for de novo sequencing, re-sequencing, the identification of single nucleotide polymorphisms and DNA methylation sites, as well as for transcriptome analysis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures









Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“RNA-Seq is well known to suffer reproducible several fold biases in the number of DNA sequence reads obtained for different GC content genomic regions (Cheung et al., 2011; Dohm et al., 2008)”
From System wide analyses have underestimated protein abundances and the importance of transcription in mammals (2014) · cites this paper as Dohm et al., 2008
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
DNA sequencing with chain-terminating inhibitors
Sanger, F., Nicklen, S., & Coulson, A. R. (1977) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.74.12.5463 · Cited by 68,572 · cited 1×
“These technologies allow sequence determination much quicker and cheaper than the dideoxy chain terminator method presented by Sanger in 1977 (2).”
MethodGenome sequencing in microfabricated high-density picolitre reactors
Margulies, M., Egholm, M., Altman, W. E., Attiya, S., Bader, J. S., Bemben, L. A., Berka, J., Braverman, M. S., Chen, Y.-J., Chen, Z., et al. (2005) · Nature · doi:10.1038/nature03959 · Cited by 7,693
High-Resolution Profiling of Histone Methylations in the Human Genome
Barski, A., Cuddapah, S., Cui, K., Roh, T.-Y., Schones, D. E., Wang, Z., Wei, G., Chepelev, I., & Zhao, K. (2007) · Cell · doi:10.1016/j.cell.2007.05.009 · Cited by 6,845 · cited 1×
“For the human genome, ultra-short reads were applied in studies on chromatin analysis (11,12).”
MethodSpecific Enzymatic Amplification of DNA In Vitro: The Polymerase Chain Reaction
Mullis, K., Faloona, F., Scharf, S., Saiki, R., Horn, G., & Erlich, H. (1986) · Cold Spring Harbor Symposia on Quantitative Biology · doi:10.1101/sqb.1986.051.01.032 · Cited by 3,558 · cited 1×
“The adoption of high-throughput sequencing will revolutionize molecular biology research, similar to the invention of the polymerase chain reaction (PCR) twenty years ago (3).”
MethodShotgun bisulphite sequencing of the Arabidopsis genome reveals DNA methylation patterning
Cokus, S. J., Feng, S., Zhang, X., Chen, Z., Merriman, B., Haudenschild, C. D., Pradhan, S., Nelson, S. F., Pellegrini, M., & Jacobsen, S. E. (2008) · Nature · doi:10.1038/nature06745 · Cited by 2,256 · cited 1×
“In the context of DNA methylation site detection by shotgun bisulfite sequencing (21), the frequency of erroneous detection of C instead of T and vice versa is of particular interest.”
BackgroundRobertson, G., Hirst, M., Bainbridge, M., Bilenky, M., Zhao, Y., Zeng, T., Euskirchen, G., Bernier, B., Varhol, R., Delaney, A., et al. (2007) · Nature Methods · doi:10.1038/nmeth1068 · Cited by 1,454 · cited 1×
“For the human genome, ultra-short reads were applied in studies on chromatin analysis (11,12).”
MethodAccuracy and quality of massively parallel DNA pyrosequencing
Huse, S. M., Huber, J. A., Morrison, H. G., Sogin, M. L., & Welch, D. M. (2007) · Genome Biology · doi:10.1186/gb-2007-8-7-r143 · Cited by 1,282 · cited 3×
“(13) estimated that 39% of all errors that had passed GS20 quality filtering occur in homopolymer length detection.”
BackgroundWhole-genome sequencing and variant discovery in C. elegans
Hillier, L. W., Marth, G. T., Quinlan, A. R., Dooling, D., Fewell, G., Barnett, D., Fox, P., Glasscock, J. I., Hickenbotham, M., Huang, W., et al. (2008) · Nature Methods · doi:10.1038/nmeth.1179 · Cited by 404
Gene discovery and annotation using LCM-454 transcriptome sequencing
Emrich, S. J., Barbazuk, W. B., Li, L., & Schnable, P. S. (2007) · Genome Research · doi:10.1101/gr.5145806 · Cited by 381
Sampling the Arabidopsis Transcriptome with Massively Parallel Pyrosequencing
Weber, A. P. M., Weber, K. L., Carr, K., Wilkerson, C., & Ohlrogge, J. B. (2007) · Plant Physiology · doi:10.1104/pp.107.096677 · Cited by 366
Cited by
TopHat: discovering splice junctions with RNA-Seq
Trapnell, C., Pachter, L., & Salzberg, S. L. (2009) · Bioinformatics · doi:10.1093/bioinformatics/btp120 · Cited by 11,617
A framework for variation discovery and genotyping using next-generation DNA sequencing data
DePristo, M. A., Banks, E., Poplin, R., Garimella, K. V., Maguire, J. R., Hartl, C., Philippakis, A. A., del Angel, G., Rivas, M. A., Hanna, M., et al. (2011) · Nature Genetics · doi:10.1038/ng.806 · Cited by 11,456
Sequencing technologies – the next generation
Metzker, M. L. (2010) · Nature Reviews Genetics · doi:10.1038/nrg2626 · Cited by 7,066
“Substitutions are the most common error type, with a higher portion of errors occurring when the previous incorporated nucleotide is a 'G' bas”
BackgroundComing of age: ten years of next-generation sequencing technologies
Goodwin, S., McPherson, J. D., & McCombie, W. R. (2016) · Nature Reviews Genetics · doi:10.1038/nrg.2016.49 · Cited by 4,352
A draft sequence of the Neandertal genome
Green, R. E., Krause, J., Briggs, A. W., Maricic, T., Stenzel, U., Kircher, M., Patterson, N., Li, H., Zhai, W., Fritz, M. H.-Y., et al. (2010) · Science · doi:10.1126/science.1188021 · Cited by 4,318
“Because we sequence each DNA fragment from both sides, and most fragments more than once (49), the latter error rate is substantially lower than the error rate of the Illumina platform itself (48, 50).”
RNA sequencing: advances, challenges and opportunities
Ozsolak, F., & Milos, P. M. (2011) · Nature Reviews Genetics · doi:10.1038/nrg2934 · Cited by 2,135
“Third, the in-solution or on-surface amplification step included in some of these approaches may introduce additional artefacts — for example, in the form of GC biases and duplicate read”
BackgroundChIP-seq guidelines and practices of the ENCODE and modENCODE consortia
Landt, S. G., Marinov, G. K., Kundaje, A., Kheradpour, P., Pauli, F., Batzoglou, S., Bernstein, B. E., Bickel, P., Brown, J. B., Cayting, P., et al. (2012) · Genome Research · doi:10.1101/gr.136184.111 · Cited by 2,033
“There are also platform-specific sequencing efficiency biases that contribute to nonuniformity (Dohm et al. 2008).”
BackgroundIdentifying ChIP-seq enrichment using MACS
Feng, J., Liu, T., Qin, B., Zhang, Y., & Liu, X. S. (2012) · Nature Protocols · doi:10.1038/nprot.2012.101 · Cited by 1,870
Bullard, J. H., Purdom, E., Hansen, K. D., & Dudoit, S. (2010) · BMC Bioinformatics · doi:10.1186/1471-2105-11-94 · Cited by 1,680
“0 arrays (GSE5350, samples AFX_1_ [A-B] [1-5]; see [Additional file 2: Supplemental Sections S1.”
TASSEL-GBS: A High Capacity Genotyping by Sequencing Analysis Pipeline
Glaubitz, J. C., Casstevens, T. M., Lu, F., Harriman, J., Elshire, R. J., Sun, Q., & Buckler, E. S. (2014) · PLoS ONE · doi:10.1371/journal.pone.0090346 · Cited by 1,625
“Furthermore, the quality scores frequently are not indicative of true quality [45,46].”
Principles and challenges of genome-wide DNA methylation analysis
Laird, P. W. (2010) · Nature Reviews Genetics · doi:10.1038/nrg2732 · Cited by 1,572
“However, the base-composition and fragment-size biases of sequencing platforms can introduce new coverage limitations and/or measurement erro”
BackgroundClinical Metagenomic Next-Generation Sequencing for Pathogen Detection
Gu, W., Miller, S., & Chiu, C. Y. (2019) · Annual Review of Pathology: Mechanisms of Disease · doi:10.1146/annurev-pathmechdis-012418-012751 · Cited by 1,458
Gnirke, A., Melnikov, A., Maguire, J., Rogov, P., LeProust, E. M., Brockman, W., Fennell, T., Giannoukos, G., Fisher, S., Russ, C., et al. (2009) · Nature Biotechnology · doi:10.1038/nbt.1523 · Cited by 1,433
SolexaQA: at-a-glance quality assessment of Illumina second-generation sequencing data
Cox, M. P., Peterson, D. A., & Biggs, P. J. (2010) · BMC Bioinformatics · doi:10.1186/1471-2105-11-485 · Cited by 1,357
“However, the error profiles of highthroughput short read sequencing technologies differ markedly from traditional Sanger sequencing [2]; they tend to exhibit a steep, exponential increase in error rates along the read length, and are susceptible to a wider range of chemistry and machine failures (such as air bubbles i…”
BackgroundHigh-Throughput Sequencing Technologies
Reuter, J. A., Spacek, D. V., & Snyder, M. P. (2015) · Molecular Cell · doi:10.1016/j.molcel.2015.05.004 · Cited by 1,338
“The exact percentage is a source of significant debate (Doolittle, 2013), highlighting the importance of further experimental evidence to assign function to genomic elements.”
BackgroundWho is eating what: diet assessment using next generation sequencing
POMPANON, F., DEAGLE, B. E., SYMONDSON, W. O. C., BROWN, D. S., JARMAN, S. N., & TABERLET, P. (2012) · Molecular Ecology · doi:10.1111/j.1365-294x.2011.05403.x · Cited by 1,293
“However, different sequencing platforms may also preferentially sequence certain amplicons (Dohm et al. 2008) or fail to completely sequence particular amplicons (Deagle et al. 2009), and this may also lead to some sequences from some targets being unrepresented in the final data set.”
BackgroundHuman housekeeping genes, revisited
Eisenberg, E., & Levanon, E. Y. (2013) · Trends in Genetics · doi:10.1016/j.tig.2013.05.010 · Cited by 1,282
RNA-Seq gene expression estimation with read mapping uncertainty
Li, B., Ruotti, V., Stewart, R. M., Thomson, J. A., & Dewey, C. N. (2010) · Bioinformatics · doi:10.1093/bioinformatics/btp692 · Cited by 1,198
“Such non-uniformity may be due to a variety of factors, including fragmentation protocols and composition biases (Dohm et al., 2008).”
BackgroundAnalyzing and minimizing PCR amplification bias in Illumina sequencing libraries
Aird, D., Ross, M. G., Chen, W.-S., Danielsson, M., Fennell, T., Russ, C., Jaffe, D. B., Nusbaum, C., & Gnirke, A. (2011) · Genome Biology · doi:10.1186/gb-2011-12-2-r18 · Cited by 1,174
“The Illumina sequencing platform [1], like other massively parallel sequencing platforms [2,3], continues to produce ever-increasing amounts of data, yet suffers from under-representation and reduced quality at loci with extreme base compositions that are recalcitrant to the technology [1,4-6].”
MethodAssembly algorithms for next-generation sequencing data
Miller, J. R., Koren, S., & Sutton, G. (2010) · Genomics · doi:10.1016/j.ygeno.2010.03.001 · Cited by 1,154
“There are published error profiles for the 454 GS 20 [11], the Illumina 1G Analyzer [12], and comparisons of three platforms [13].”
Detection and quantification of rare mutations with massively parallel sequencing
Kinde, I., Wu, J., Papadopoulos, N., Kinzler, K. W., & Vogelstein, B. (2011) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1105422108 · Cited by 1,144
“05% (33, 34), depending on factors such as the read length (35), use of improved base-calling algorithms (36–38), and the type of variants detected (39).”
BackgroundNoninvasive diagnosis of fetal aneuploidy by shotgun sequencing DNA from maternal blood
Fan, H. C., Blumenfeld, Y. J., Chitkara, U., Hudgins, L., & Quake, S. R. (2008) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0808319105 · Cited by 1,114
“We strongly suspect that it is an artifact because we also observe GC bias on genomic DNA control, and such bias on the Solexa sequencing platform has recently been reported (38, 39).”
BackgroundHybrid error correction and de novo assembly of single-molecule sequencing reads
Koren, S., Schatz, M. C., Walenz, B. P., Martin, J., Howard, J. T., Ganapathy, G., Wang, Z., Rasko, D. A., McCombie, W. R., Jarvis, E. D., et al. (2012) · Nature Biotechnology · doi:10.1038/nbt.2280 · Cited by 1,011
“First, they require amplification of source DNA before sequencing, leading to amplification artifacts 4 and biased coverage of the genome related to the chemical-physical properties of the DNA 5 .”
BackgroundInfluentialExtracellular miRNAs: From Biomarkers to Mediators of Physiology and Disease
Mori, M. A., Ludwig, R. G., Garcia-Martin, R., Brandão, B. B., & Kahn, C. R. (2019) · Cell Metabolism · doi:10.1016/j.cmet.2019.07.011 · Cited by 961
“RT-qPCR is more sensitive and not limited by sequence-abundance bias (Dohm et al., 2008; Hansen et al., 2010; Zheng et al., 2011), but the technique requires optimization, proper standard curves, and ideally the inclusion of spiked-in exogenous miRNAs (Huggett et al.”
BackgroundNext-generation sequencing technologies and their implications for crop genetics and breeding
Varshney, R. K., Nayak, S. N., May, G. D., & Jackson, S. A. (2009) · Trends in Biotechnology · doi:10.1016/j.tibtech.2009.05.006 · Cited by 936
Summarizing and correcting the GC content bias in high-throughput sequencing
Benjamini, Y., & Speed, T. P. (2012) · Nucleic Acids Research · doi:10.1093/nar/gks001 · Cited by 913
“(1), probably because GC-rich areas are rare (especially in simpler organisms).”
BackgroundHigh-throughput genotyping by whole-genome resequencing
Huang, X., Feng, Q., Qian, Q., Zhao, Q., Wang, L., Wang, A., Guan, J., Fan, D., Weng, Q., Huang, T., et al. (2009) · Genome Research · doi:10.1101/gr.089516.108 · Cited by 910
“Given the estimated average per-base error rate of 0.3% at the 59 end of Illumina GA reads (Dohm et al. 2008), the sequence error rate for the first two bases of the index combined is 0.6%.”
BackgroundInfluentialCharacterizing and measuring bias in sequence data
Ross, M. G., Russ, C., Costello, M., Hollinger, A., Lennon, N. J., Hegarty, R., Nusbaum, C., & Jaffe, D. B. (2013) · Genome Biology · doi:10.1186/gb-2013-14-5-r51 · Cited by 909
“Illumina sequencing [18] has been shown to lose coverage in regions of high or low GC [19-22], a phenomenon also seen in other ‘ next-generation ’ technologies [3,6].”
BackgroundGC-Content Normalization for RNA-Seq Data
Risso, D., Schwartz, K., Sherlock, G., & Dudoit, S. (2011) · BMC Bioinformatics · doi:10.1186/1471-2105-12-480 · Cited by 867
“, uniqueness of a particular sequence compared to the rest of the genome) [3, 6–20].”
BackgroundNext-Generation Sequencing: From Basic Research to Diagnostics
Voelkerding, K. V., Dames, S. A., & Durtschi, J. D. (2009) · Clinical Chemistry · doi:10.1373/clinchem.2008.112789 · Cited by 839
“Clinical Chemistry 55:4 (2009) 11 coverage depths (50- to 60-fold) have been used in an effort to improve short-read alignment, assembly, and accuracy,althoughcoverageinthe20-to30-foldrange may be sufficient for certain resequencing applications ( 14 ).”
BackgroundMethodInfluentialInsight into biases and sequencing errors for amplicon sequencing with the Illumina MiSeq platform
Schirmer, M., Ijaz, U. Z., D'Amore, R., Hall, N., Sloan, W. T., & Quince, C. (2015) · Nucleic Acids Research · doi:10.1093/nar/gku1341 · Cited by 749
“So as the read length increases, the cluster signal can get weaker due to an accumulation of these events resulting in higher error rates towards the end of the read (16).”
Background't Hoen, P. A. C., Ariyurek, Y., Thygesen, H. H., Vreugdenhil, E., Vossen, R. H. A. M., de Menezes, R. X., Boer, J. M., van Ommen, G.-J. B., & den Dunnen, J. T. (2008) · Nucleic Acids Research · doi:10.1093/nar/gkn705 · Cited by 742
“Thus, the GC bias in DGE seems to be limited, but needs further investigation, also in the light of a recently published study where considerable overrepresentation of GC-rich sequences was observed in Solexa/Illumina-based resequencing experiments (49).”
BackgroundBiases in Illumina transcriptome sequencing caused by random hexamer priming
Hansen, K. D., Brenner, S. E., & Dudoit, S. (2010) · Nucleic Acids Research · doi:10.1093/nar/gkq224 · Cited by 713
“General biases in DNA sequencing using the Illumina platform have been studied in (2).”
BackgroundMethodNavigating the tip of the genomic iceberg: Next‐generation sequencing for plant systematics
Straub, S. C. K., Parks, M., Weitemier, K., Fishbein, M., Cronn, R. C., & Liston, A. (2012) · American Journal of Botany · doi:10.3732/ajb.1100335 · Cited by 696
High‐throughput DNA sequencing – concepts and limitations
Kircher, M., & Kelso, J. (2010) · BioEssays · doi:10.1002/bies.200900181 · Cited by 671
“Therefore, the highest substitution errors observed are between A/C and G/T [41, 42].”
BackgroundInfluentialA molecular portrait of microsatellite instability across multiple cancers
Cortes-Ciriano, I., Lee, S., Park, W.-Y., Kim, T.-M., & Park, P. J. (2017) · Nature Communications · doi:10.1038/ncomms15180 · Cited by 658
Synthetic spike-in standards for RNA-seq experiments
Jiang, L., Schlesinger, F., Davis, C. A., Zhang, Y., Li, R., Salit, M., Gingeras, T. R., & Oliver, B. (2011) · Genome Research · doi:10.1101/gr.121095.111 · Cited by 653
“Several studies have identified biases and errors resulting from library construction and sequencing chemistry on the Illumina instruments (Dohm et al. 2008; Bullard et al. 2010; Hansen et al. 2010; Li et al. 2010).”
BackgroundOptimizing illumina next-generation sequencing library preparation for extremely at-biased genomes
Oyola, S. O., Otto, T. D., Gu, Y., Maslen, G., Manske, M., Campino, S., Turner, D. J., MacInnis, B., Kwiatkowski, D. P., Swerdlow, H. P., et al. (2012) · BMC Genomics · doi:10.1186/1471-2164-13-1 · Cited by 653
“Although biased base composition has been a challenge to the Sanger sequencing methods, it has continued to be a major problem for the current highthroughput Next-Generation Sequencing (NGS) technologies [3].”
BackgroundChromatin organization marks exon-intron structure
Schwartz, S., Meshorer, E., & Ast, G. (2009) · Nature Structural & Molecular Biology · doi:10.1038/nsmb.1659 · Cited by 638
Minoche, A. E., Dohm, J. C., & Himmelbauer, H. (2011) · Genome Biology · doi:10.1186/gb-2011-12-11-r112 · Cited by 629
“The finding that templates such as ZR with a %GC varying from 24% to 47% (1st and 99th percentiles) show increased coverage of GC-rich regions when using Illumina standard protocols is in accordance with previous results [2,4].”
BackgroundMethodResultInfluentialSelf-citationEvaluation of next generation sequencing platforms for population targeted sequencing studies
Harismendy, O., Ng, P. C., Strausberg, R. L., Wang, X., Stockwell, T. B., Beeson, K. Y., Schork, N. J., Murray, S. S., Topol, E. J., Levy, S., et al. (2009) · Genome Biology · doi:10.1186/gb-2009-10-3-r32 · Cited by 614
“depth coverage decreases with increasing AT content, which is consistent with previous studies [17,18] (Supplemental Figure 1 in Additional data file 3).”
ResultStatistics or biology: the zero-inflation controversy about scRNA-seq data
Jiang, R., Sun, T., Song, D., & Li, J. J. (2022) · Genome Biology · doi:10.1186/s13059-022-02601-5 · Cited by 614
“Moreover, cDNA copy number biases would accumulate as the number of amplification cycles increases [81, 85]; that is, the more cycles, the larger the difference of two genes (with different amplification efficiency) in cDNA copy numbers [86, 87].”
BackgroundYaffe, E., & Tanay, A. (2011) · Nature Genetics · doi:10.1038/ng.947 · Cited by 610
“A known major source of bias in sequencing experiments is the nucleotide composition of the DNA under stud”
BackgroundRemoving technical variability in RNA-seq data using conditional quantile normalization
Hansen, K. D., Irizarry, R. A., & WU, Z. (2012) · Biostatistics · doi:10.1093/biostatistics/kxr054 · Cited by 607
Sequence-specific error profile of Illumina sequencers
Nakamura, K., Oshima, T., Morimoto, T., Ikeda, S., Yoshikawa, H., Shiwa, Y., Ishikawa, S., Linak, M. C., Hirai, A., Takahashi, H., et al. (2011) · Nucleic Acids Research · doi:10.1093/nar/gkr344 · Cited by 600
“(28), miscalls are more frequently distributed in the GC-rich regions.”
BackgroundAdvancements in Next-Generation Sequencing
Levy, S. E., & Myers, R. M. (2016) · Annual Review of Genomics and Human Genetics · doi:10.1146/annurev-genom-083115-022413 · Cited by 599
A survey of tools for variant analysis of next-generation genome sequencing data
Pabinger, S., Dander, A., Fischer, M., Snajder, R., Sperk, M., Efremova, M., Krabichler, B., Speicher, M. R., Zschocke, J., & Trajanoski, Z. (2014) · Briefings in Bioinformatics · doi:10.1093/bib/bbs086 · Cited by 596
“These errors are quite common in sequencing data, and platforms are susceptible to a wide range of chemistry and instrument failures [55, 56].”
BackgroundKofler, R., Orozco-terWengel, P., De Maio, N., Pandey, R. V., Nolte, V., Futschik, A., Kosiol, C., & Schlötterer, C. (2011) · PLoS ONE · doi:10.1371/journal.pone.0015925 · Cited by 590
“Sequencing errors are not evenly distributed along sequence reads [14].”
BackgroundQuake: quality-aware detection and correction of sequencing errors
Kelley, D. R., Schatz, M. C., & Salzberg, S. L. (2010) · Genome Biology · doi:10.1186/gb-2010-11-11-r116 · Cited by 582
“For example, one study found A to C was the most frequent error, likely because A and C are detected by one laser while G and T are detected by another [26].”
BackgroundMethodInfluentialApplications of New Sequencing Technologies for Transcriptome Analysis
Morozova, O., Hirst, M., & Marra, M. A. (2009) · Annual Review of Genomics and Human Genetics · doi:10.1146/annurev-genom-082908-145957 · Cited by 572
Kozarewa, I., Ning, Z., Quail, M. A., Sanders, M. J., Berriman, M., & Turner, D. J. (2009) · Nature Methods · doi:10.1038/nmeth.1311 · Cited by 564
“, the PCR is still a source of duplicate sequences, amplification bias and struggles with (A+T)-rich base composition”
Computational methods for discovering structural variation with next-generation sequencing
Medvedev, P., Stanciu, M., & Brudno, M. (2009) · Nature Methods · doi:10.1038/nmeth.1374 · Cited by 552
“Though the bias in G+C rich regions and in homopolymeric stretches of DNA has been well documente”
Fast Mapping of Short Sequences with Mismatches, Insertions and Deletions Using Index Structures
Hoffmann, S., Otto, C., Kurtz, S., Sharma, C. M., Khaitovich, P., Vogel, J., Stadler, P. F., & Hackermüller, J. (2009) · PLoS Computational Biology · doi:10.1371/journal.pcbi.1000502 · Cited by 535
“In Illumina reads, error rates of up to 4% have been observed [6].”
BackgroundLiu, J., Sui, Y., Yu, Z., Shi, Y., Chu, H., Jin, J., Liu, X., & Wang, G. (2014) · Soil Biology and Biochemistry · doi:10.1016/j.soilbio.2013.12.014 · Cited by 523
“Considering the sources of errors described in previous studies that used 454 sequencing (Dohm et al., 2008), in this study, only sequences >200 bp in length, with an average quality score >25, without ambiguous base calls and with at least an 80% match to a Table 1 Soil physical and chemical…”
MethodPerformance comparison of exome DNA sequencing technologies
Clark, M. J., Chen, R., Lam, H. Y. K., Karczewski, K. J., Chen, R., Euskirchen, G., Butte, A. J., & Snyder, M. (2011) · Nature Biotechnology · doi:10.1038/nbt.1975 · Cited by 511
High-resolution mapping of copy-number alterations with massively parallel sequencing
Chiang, D. Y., Getz, G., Jaffe, D. B., O'Kelly, M. J. T., Zhao, X., Carter, S. L., Russ, C., Nusbaum, C., Meyerson, M., & Lander, E. S. (2009) · Nature Methods · doi:10.1038/nmeth.1276 · Cited by 510
“We anticipate that each massively parallel sequencing platform may be susceptible to particular biase”
Backgroundproovread : large-scale high-accuracy PacBio correction through iterative short read consensus
Hackl, T., Hedrich, R., Schultz, J., & Förster, F. (2014) · Bioinformatics · doi:10.1093/bioinformatics/btu392 · Cited by 510
Assembly of large genomes using second-generation sequencing
Schatz, M. C., Delcher, A. L., & Salzberg, S. L. (2010) · Genome Research · doi:10.1101/gr.101360.109 · Cited by 499
Chan, K. A., Jiang, P., Zheng, Y. W., Liao, G. J., Sun, H., Wong, J., Siu, S. S. N., Chan, W. C., Chan, S. L., Chan, A. T., et al. (2013) · Clinical Chemistry · doi:10.1373/clinchem.2012.196014 · Cited by 488
Searching for SNPs with cloud computing
Langmead, B., Schatz, M. C., Lin, J., Pop, M., & Salzberg, S. L. (2009) · Genome Biology · doi:10.1186/gb-2009-10-11-r134 · Cited by 484
“To account for base-calling errors and inaccurate quality values reported by the Illumina software pipeline [29,30], SOAPsnp recalibrates quality values according to a fourdimensional matrix recording observed error rates.”
MethodKlambauer, G., Schwarzbauer, K., Mayr, A., Clevert, D.-A., Mitterecker, A., Bodenhofer, U., & Hochreiter, S. (2012) · Nucleic Acids Research · doi:10.1093/nar/gks003 · Cited by 455
“Copy number analysis by NGS has the following potential advantages compared with array-based techniques: (i) estimation of integer copy numbers from NGS data is more accurate for large copy numbers, since depths of coverage scale linearly with copy numbers (6).”
InfluentialCompressed Weighted de Bruijn Graphs
Liu, B., Shi, Y., Yuan, J., Hu, X., Zhang, H., Li, N., Li, Z., Chen, Y., Mu, D., & Fan, W. (2013) · arXiv (Cornell University) · doi:10.4230/lipics.cpm.2021.16 · Cited by 445
PCR Biases Distort Bacterial and Archaeal Community Structure in Pyrosequencing Datasets
Pinto, A. J., & Raskin, L. (2012) · PLoS ONE · doi:10.1371/journal.pone.0043093 · Cited by 443
“The GC Content of a Sample Library Affects the Number of Final Reads Previous work has shown that GC content may have a strong effect on PCR [32,42,43] and whole genome amplification [44], and on whole genome sequencing using the Illumina [45] and 454-GS-FLX and Titanium platforms [46].”
MethodInfluentialNext-generation sequencing for cancer diagnostics: a practical perspective.
Meldrum, C. J., Doyle, M., & Tothill, R. W. (2011) · Europe PMC (PubMed Central) · Cited by 443
Uncovering the Complexity of Transcriptomes with RNA-Seq
Costa, V., Angelini, C., De Feis, I., & Ciccodicola, A. (2010) · Journal of Biomedicine and Biotechnology · doi:10.1155/2010/853916 · Cited by 439
Analysis of Australian fur seal diet by pyrosequencing prey DNA in faeces
DEAGLE, B. E., KIRKWOOD, R., & JARMAN, S. N. (2009) · Molecular Ecology · doi:10.1111/j.1365-294x.2009.04158.x · Cited by 425
“One systematic analysis of sequencing biases has been published on data produced with Solexa high-throughput technology (Dohm et al. 2008), but we are unaware of any for the GSFLX system.”
BackgroundDalloul, R. A., Long, J. A., Zimin, A. V., Aslam, L., Beal, K., Ann Blomberg, L., Bouffard, P., Burt, D. W., Crasta, O., Crooijmans, R. P. M. A., et al. (2010) · PLoS Biology · doi:10.1371/journal.pbio.1000475 · Cited by 416
“These results suggest that absence of HSA19q orthologous sequences is not due to the high GC content, in that Illumina sequences show a bias towards higher coverage of GC rich regions [19,20].”
BackgroundKaufmann, K., Muiño, J. M., Østerås, M., Farinelli, L., Krajewski, P., & Angenent, G. C. (2010) · Nature Protocols · doi:10.1038/nprot.2009.244 · Cited by 415
Mutational and fitness landscapes of an RNA virus revealed through population sequencing
Acevedo, A., Brodsky, L., & Andino, R. (2014) · Nature · doi:10.1038/nature12861 · Cited by 391
The Landscape of Microsatellite Instability in Colorectal and Endometrial Cancer Genomes
Kim, T.-M., Laird, P. W., & Park, P. J. (2013) · Cell · doi:10.1016/j.cell.2013.10.015 · Cited by 380
“In this study, we used data from the Illumina platform, which uses reversible terminators that allows incorporation of just a single nucleotide at a time and is currently the most reliable platform with respect to the homopolymer issue (Dohm et al., 2008).”
Illumina error profiles: resolving fine-scale variation in metagenomic sequencing data
Schirmer, M., D’Amore, R., Ijaz, U. Z., Hall, N., & Quince, C. (2016) · BMC Bioinformatics · doi:10.1186/s12859-016-0976-y · Cited by 376
“They found that errors are frequently preceded by G [5].”
BackgroundAccuracy and quality assessment of 454 GS-FLX Titanium pyrosequencing
Gilles, A., Meglécz, E., Pech, N., Ferreira, S., Malausa, T., & Martin, J.-F. (2011) · BMC Genomics · doi:10.1186/1471-2164-12-245 · Cited by 373
“tions and deletions of single bases occur less frequently than mismatches [13,14].”
BackgroundAndino, R., & Domingo, E. (2015) · Virology · doi:10.1016/j.virol.2015.03.022 · Cited by 368
“Here we review progress in three salient and interconnected features of viral quasispecies that have acquired increasing prominence in recent years: (i) the internal interactions of complementation and interference that are established within mutant spectra, that renders selection at a collective level possible; (ii)…”
BackgroundInfluentialThe Majority of Primate-Specific Regulatory Sequences Are Derived from Transposable Elements
Jacques, P.-É., Jeyakani, J., & Bourque, G. (2013) · PLoS Genetics · doi:10.1371/journal.pgen.1003504 · Cited by 355
“[25].”
Understanding sequencing data as compositions: an outlook and review
Quinn, T. P., Erb, I., Richardson, M. F., & Crowley, T. M. (2018) · Bioinformatics · doi:10.1093/bioinformatics/bty175 · Cited by 350
“The second is GC content bias, in which more reads map to high GC regions ([19]).”
Malla, M. A., Dubey, A., Kumar, A., Yadav, S., Hashem, A., & Abd_Allah, E. F. (2019) · Frontiers in Immunology · doi:10.3389/fimmu.2018.02868 · Cited by 345
“Illumina sequencing technology has made tremendous advances in data output and cost efficiency over the past few years and as a result, presently dominates the NGS market (129, 130).”
BackgroundSystematic evaluation of error rates and causes in short samples in next-generation sequencing
Pfeiffer, F., Gröber, C., Blank, M., Händler, K., Beyer, M., Schultze, J. L., & Mayer, G. (2018) · Scientific Reports · doi:10.1038/s41598-018-29325-6 · Cited by 336
Neveling, K., Feenstra, I., Gilissen, C., Hoefsloot, L. H., Kamsteeg, E.-J., Mensenkamp, A. R., Rodenburg, R. J. T., Yntema, H. G., Spruijt, L., Vermeer, S., et al. (2013) · Human Mutation · doi:10.1002/humu.22450 · Cited by 331
“Reasons for regions not being well covered are in most cases high GC content or repetitive elements [Dohm et al., 2008; Hoischen et al., 2010a; Kalari et al., 2006].”
BackgroundZimmermann, B., Hill, M., Gemelos, G., Demko, Z., Banjevic, M., Baner, J., Ryan, A., Sigurjonsson, S., Chopra, N., Dodd, M., et al. (2012) · Prenatal Diagnosis · doi:10.1002/pd.3993 · Cited by 328
Detecting Heteroplasmy from High-Throughput Sequencing of Complete Human Mitochondrial DNA Genomes
Li, M., Schönberg, A., Schaefer, M., Schroeder, R., Nasidze, I., & Stoneking, M. (2010) · The American Journal of Human Genetics · doi:10.1016/j.ajhg.2010.07.014 · Cited by 325
Genomic structure in Europeans dating back at least 36,200 years
Seguin-Orlando, A., Korneliussen, T. S., Sikora, M., Malaspinas, A.-S., Manica, A., Moltke, I., Albrechtsen, A., Ko, A., Margaryan, A., Moiseyev, V., et al. (2014) · Science · doi:10.1126/science.aaa0114 · Cited by 315
Balanced Codon Usage Optimizes Eukaryotic Translational Efficiency
Qian, W., Yang, J.-R., Pearson, N. M., Maclean, C., & Zhang, J. (2012) · PLoS Genetics · doi:10.1371/journal.pgen.1002603 · Cited by 310
“Although Illumina sequencing may be biased toward certain sequences or nucleotides [64], this bias affects the mRNA-Seq and ribosome profiling data equally and thus will not affect our estimation of CST.”
BackgroundThe venom-gland transcriptome of the eastern diamondback rattlesnake (Crotalus adamanteus)
Rokyta, D. R., Lemmon, A. R., Margres, M. J., & Aronow, K. (2012) · BMC Genomics · doi:10.1186/1471-2164-13-312 · Cited by 306
“Clusters could include alleles, recent duplicates, or even sequencing errors, which are characteristic of high-throughput sequencing [42].”
BackgroundSources of PCR-induced distortions in high-throughput sequencing data sets
Kebschull, J. M., & Zador, A. M. (2015) · Nucleic Acids Research · doi:10.1093/nar/gkv717 · Cited by 299
Denoising DNA deep sequencing data—high-throughput sequencing errors and their correction
Laehnemann, D., Borkhardt, A., & McHardy, A. C. (2016) · Briefings in Bioinformatics · doi:10.1093/bib/bbv029 · Cited by 296
“Illumina sequencing by synthesis The error profiles of the current Illumina sequencing by synthesis platforms HiSeq and MiSeq have been characterized in substantial detail, also drawing on the rigorous analyses of earlier Illumina platforms such as the 1 G [20, 21] and the Genome Analyzer II [22].”
MethodFaircloth, B. C., & Glenn, T. C. (2012) · PLoS ONE · doi:10.1371/journal.pone.0042543 · Cited by 289
“, Illumina, Ion Torrent and Roche) with most errors occurring at the beginning and end of reads [18,22,29].”
BackgroundNoninvasive Prenatal Diagnosis of Fetal Trisomy 18 and Trisomy 13 by Maternal Plasma DNA Sequencing
Chen, E. Z., Chiu, R. W. K., Sun, H., Akolekar, R., Chan, K. C. A., Leung, T. Y., Jiang, P., Zheng, Y. W. L., Lun, F. M. F., Chan, L. Y. S., et al. (2011) · PLoS ONE · doi:10.1371/journal.pone.0021791 · Cited by 289
Musket: a multistage k-mer spectrum-based error corrector for Illumina sequence data
Liu, Y., Schröder, J., & Schmidt, B. (2013) · Bioinformatics · doi:10.1093/bioinformatics/bts690 · Cited by 287
Effects of GC Bias in Next-Generation-Sequencing Data on De Novo Genome Assembly
Chen, Y.-C., Liu, T., Yu, C.-H., Chiang, T.-Y., & Hwang, C.-C. (2013) · PLoS ONE · doi:10.1371/journal.pone.0062856 · Cited by 285
“On Illumina system [9], a major NGS platform, it has been reported that extreme base compositions, i.e., GC-poor or GC-rich sequences, lead to an uneven coverage or even no coverage of reads across the genome [9,10,11,12,13].”
BackgroundResultPergament, E., Cuckle, H., Zimmermann, B., Banjevic, M., Sigurjonsson, S., Ryan, A., Hall, M. P., Dodd, M., Lacroute, P., Stosic, M., et al. (2014) · Obstetrics & Gynecology · doi:10.1097/aog.0000000000000363 · Cited by 284
“4% with false-positive rates as high as 1%,(6,8,13,20) partially attributed to amplification efficiency variation.(21,22) Although GC correction can improve chromosome 13 sensitivity,(23) similar corrections have not been reported for the X chromosome.”
BackgroundRapid evaluation and quality control of next generation sequencing data with FaQCs
Lo, C.-C., & Chain, P. S. G. (2014) · BMC Bioinformatics · doi:10.1186/s12859-014-0366-2 · Cited by 284
“reactions, coupled with occasional issues in detecting the signal from polymerase extension [1,2].”
BackgroundModelling and simulating generic RNA-Seq experiments with the flux simulator
Griebel, T., Zacher, B., Ribeca, P., Raineri, E., Lacroix, V., Guigó, R., & Sammeth, M. (2012) · Nucleic Acids Research · doi:10.1093/nar/gks666 · Cited by 281
“Amplification efficiency is known to depend on the GC content of the respective molecule (17), although controversial reports on the correlation between GC content and RNA-Seq coverage have been published (6,17,19).”
BackgroundThe challenges of sequencing by synthesis
Fuller, C. W., Middendorf, L. R., Benner, S. A., Church, G. M., Harris, T., Huang, X., Jovanovich, S. B., Nelson, J. R., Schloss, J. A., Schwartz, D. C., et al. (2009) · Nature Biotechnology · doi:10.1038/nbt.1585 · Cited by 280
Li, J. J., Bickel, P. J., & Biggin, M. D. (2014) · PeerJ · doi:10.7717/peerj.270 · Cited by 279
“RNA-Seq is well known to suffer reproducible several fold biases in the number of DNA sequence reads obtained for different GC content genomic regions (Cheung et al., 2011; Dohm et al., 2008).”
BackgroundShiroguchi, K., Jia, T. Z., Sims, P. A., & Xie, X. S. (2012) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1118018109 · Cited by 276
“The interpretation of conventional RNA-Seq is complicated by sequence-dependent bias and amplification noise from reverse transcription, adapter ligation, library amplification by PCR, solid-phase clonal amplification, and sequencing (3-5).”
MethodMartí, E., Pantano, L., Bañez-Coronel, M., Llorens, F., Miñones-Moyano, E., Porta, S., Sumoy, L., Ferrer, I., & Estivill, X. (2010) · Nucleic Acids Research · doi:10.1093/nar/gkq575 · Cited by 276
“Fifth, we applied the Z-score option to exclude sequencing errors as the possible cause of the nucleotide changes observed in the isomiR (27).”
BackgroundMethodResultInfluentialKorbel, J. O., Abyzov, A., Mu, X. J., Carriero, N., Cayting, P., Zhang, Z., Snyder, M., & Gerstein, M. B. (2009) · Genome Biology · doi:10.1186/gb-2009-10-2-r23 · Cited by 272
“For the Solexa sequencing error we approximated the average substitution rate of the Solexa/Illumina platform [44] using a simple model involving a fourth degree polynomial.”
G+C content dominates intrinsic nucleosome occupancy
Tillo, D., & Hughes, T. R. (2009) · BMC Bioinformatics · doi:10.1186/1471-2105-10-442 · Cited by 269
“Since the 14 feature model is trained on Illumina/Solexa sequencing data, which may have inherent biases[33], it is important to note that it also correlates well with an in vivo nucleosome organization from a tiling array study in yeast[2] and a sequencing-based study in C.”
MethodSuárez-Fariñas, M., Ungar, B., Correa da Rosa, J., Ewald, D. A., Rozenblit, M., Gonzalez, J., Xu, H., Zheng, X., Peng, X., Estrada, Y. D., et al. (2015) · Journal of Allergy and Clinical Immunology · doi:10.1016/j.jaci.2015.03.003 · Cited by 268
Lombard, N., Prestat, E., van Elsas, J. D., & Simonet, P. (2011) · FEMS Microbiology Ecology · doi:10.1111/j.1574-6941.2011.01140.x · Cited by 263
Metadata
- Authors
- Dohm, J. C., Lottaz, C., Borodina, T., & Himmelbauer, H.
- Affiliations
- Max Planck Institute for Molecular Genetics (DE)
- University of Regensburg (DE)
- Max Planck Society (DE)
- Corresponding author
- Himmelbauer, Heinz
- Venue
- Nucleic Acids Research
- Publisher
- Oxford University Press (OUP)
- Published
- 2008-07-26
- Volume
- 36
- Issue
- 16
- Pages
- e105-e105
- ISSN
- 0305-1048 (ISSN-L)
- 1362-4962
- PMC
- PMC2532726
- OpenAlex
- W2131088968
- Cited by
- 1,088
- References
- 22
- Citations by year
- 2026: 14 · 2025: 18 · 2024: 17 · 2023: 20 · 2022: 36 · 2021: 40 · 2020: 46 · 2019: 52 · 2018: 45 · 2017: 70 · 2016: 69 · 2015: 76 · 2014: 104 · 2013: 109 · 2012: 100
- FWCI
- 37.26
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- Nucleic Acids Research (publishedVersion, cc-by-nc)
- PubMed Central (publishedVersion, cc-by-nc)
- PubMed (publishedVersion)
- University of Regensburg Publication Server (University of Regensburg) (acceptedVersion)
- Max Planck Institute for Plasma Physics (submittedVersion)
- University of Regensburg Publication Server (University of Regensburg)
- Funders
- Max-Planck-Gesellschaft
- Topics
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Genomics and Phylogenetic Studies
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Fractal and DNA sequence analysis
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Gene expression and cancer classification
- Keywords
- sequencing error rate, insertion and deletion errors, GC content, resequencing, Beta vulgaris, de novo sequencing, single nucleotide polymorphisms, gene expression profiling
- MeSH terms
- Base Composition, DNA, Software, Helicobacter, Sequence Deletion, Sequence Analysis, DNA, Beta vulgaris
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.