CoChat

Effect of aluminium load on parathyroid hormone synthesis

Díaz‐Corte, Carmen, Fernández‐Martín, Jose Luis, Barreto, Susana, Gómez, Carlos, Fernández‐Coto, Teresa, Braga, Socorro, Cannata, Jorge B. · 2001 · Nephrology Dialysis Transplantation
Cited by 50

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

BACKGROUND: Aluminium overload leads to parathyroid hormone (PTH) suppression. However, it is unclear whether a decrease in synthesis or release of the hormone is mainly involved. The aim of this study was to assess the effect of an acute administration of aluminium on PTH synthesis and release in rats with chronic renal failure and secondary hyperparathyroidism. METHODS: The study was performed using 100 adult male Wistar rats (body weight 443+/-54 g). 7/8 nephrectomy was performed and the rats were maintained on a high dietary phosphorous intake. Five weeks after surgery, the rats were randomly divided into two groups, one loaded with aluminium (AlCl3) and the other given placebo. Aluminium or placebo were administered i.p. for two consecutive days. The placebo group received saline at the same pH as the aluminium solution. After 2 weeks, serum calcium, phosphorous, creatinine, PTH, and aluminium were measured. The parathyroid glands were removed and PTH messenger RNA (mRNA) was measured by northern blot. Intact PTH was measured by IRMA (Rat PTH, Nichols Institute). RESULTS: No differences in serum PTH levels were found between the two groups after 5 weeks of renal failure. At the end of the study the rats given aluminium had higher aluminium levels than the placebo group and lower PTH levels. No significant differences were found for calcium, phosphorous, renal function, or body weight. PTH mRNA expression was lower in the aluminium group than in the placebo group. CONCLUSION: The administration of aluminium in rats with chronic renal failure resulted in reductions in serum PTH and PTH mRNA. Thus far, previous studies had demonstrated that aluminium suppressed PTH release. The present findings suggest that PTH synthesis is also reduced.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/ndt/16.4.742

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 50

Metadata

Authors
Díaz‐Corte, C., Fernández‐Martín, J. L., Barreto, S., Gómez, C., Fernández‐Coto, T., Braga, S., & Cannata, J. B.
Venue
Nephrology Dialysis Transplantation
Published
2001-04-01
Volume
16
Issue
4
Pages
742-745
ISSN
  • 0931-0509 (ISSN-L)
  • 1460-2385
OpenAlex
W1965325842
Cited by
50
References
2
FWCI
2.01
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.