Consensus recommendations for a dynamic susceptibility contrast MRI protocol for use in high-grade gliomas
Open accessThe DOI matches its Crossref record; 68 of the 68 references it cites were found in a registry or an index.
Abstract
Despite the widespread clinical use of dynamic susceptibility contrast (DSC) MRI, DSC-MRI methodology has not been standardized, hindering its utilization for response assessment in multicenter trials. Recently, the DSC-MRI Standardization Subcommittee of the Jumpstarting Brain Tumor Drug Development Coalition issued an updated consensus DSC-MRI protocol compatible with the standardized brain tumor imaging protocol (BTIP) for high-grade gliomas that is increasingly used in the clinical setting and is the default MRI protocol for the National Clinical Trials Network. After reviewing the basis for controversy over DSC-MRI protocols, this paper provides evidence-based best practices for clinical DSC-MRI as determined by the Committee, including pulse sequence (gradient echo vs spin echo), BTIP-compliant contrast agent dosing (preload and bolus), flip angle (FA), echo time (TE), and post-processing leakage correction. In summary, full-dose preload, full-dose bolus dosing using intermediate (60°) FA and field strength-dependent TE (40–50 ms at 1.5 T, 20–35 ms at 3 T) provides overall best accuracy and precision for cerebral blood volume estimates. When single-dose contrast agent usage is desired, no-preload, full-dose bolus dosing using low FA (30°) and field strength-dependent TE provides excellent performance, with reduced contrast agent usage and elimination of potential systematic errors introduced by variations in preload dose and incubation time.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Wen, P. Y., Macdonald, D. R., Reardon, D. A., Cloughesy, T. F., Sorensen, A. G., Galanis, E., DeGroot, J., Wick, W., Gilbert, M. R., Lassman, A. B., et al. (2010) · Journal of Clinical Oncology · doi:10.1200/jco.2009.26.3541 · Cited by 3,836
Self-citationFunctional mapping of the human visual cortex by magnetic resonance imaging
Belliveau, J. W., Kennedy, D. N., McKinstry, R. C., Buchbinder, B. R., Weisskoff, R. M., Cohen, M. S., Vevea, J. M., Brady, T. J., & Rosen, B. R. (1991) · Science · doi:10.1126/science.1948051 · Cited by 1,883
Self-citationØstergaard, L., Weisskoff, R. M., Chesler, D. A., Gyldensted, C., & Rosen, B. R. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910360510 · Cited by 1,512
Self-citationOn the Theory of the Indicator-Dilution Method for Measurement of Blood Flow and Volume
Meier, P., & Zierler, K. L. (1954) · Journal of Applied Physiology · doi:10.1152/jappl.1954.6.12.731 · Cited by 1,274 · cited 1×
“DSC-MRI is based upon classical indicator dilution theory used by physiologists to quantitate hemodynamics of whole-organ systems from known quantities of injected non-diffusible tracers such as dyes and radiotracers, and measurement of output tracer concentration.(31) DSC-MRI applies this methodology to -MRI is a cqu…”
Perfusion imaging with NMR contrast agents
Rosen, B. R., Belliveau, J. W., Vevea, J. M., & Brady, T. J. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910140211 · Cited by 1,151 · cited 1×
“applyparastyle "fig//caption/p[1]" parastyle "FigCapt" applyparastyle "fig" parastyle "Figure"”
Self-citationMr contrast due to intravascular magnetic susceptibility perturbations
Boxerman, J. L., Hamberg, L. M., Rosen, B. R., & Weisskoff, R. M. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910340412 · Cited by 1,008 · cited 3×
“Protons lose phase coherence as they diffuse through the transient, spatially varying gradients, yielding signal attenuation dependent upon physiological factors, including vessel or compartment size and proton diffusion rate, and experimental factors, including pulse sequence parameters and contrast agent concentrati…”
Self-citationCerebral blood volume maps of gliomas: comparison with tumor grade and histologic findings.
Aronen, H. J., Gazit, I. E., Louis, D. N., Buchbinder, B. R., Pardo, F. S., Weisskoff, R. M., Harsh, G. R., Cosgrove, G. R., Halpern, E. F., & Hochberg, F. H. (1994) · Radiology · doi:10.1148/radiology.191.1.8134596 · Cited by 908 · cited 1×
“DSC-MRI -induced brain activation,(2) and produce the first MRI-based CBV maps of gliomas.(3) Since these beginnings, studies have shown that DSC-MRI may be more useful than standard MRI at predicting treatment-naïve glioma grade(3-8) and survival,(9-13) distinguishing post-treatment pseudoprogression and radiation ne…”
Microscopic susceptibility variation and transverse relaxation: Theory and experiment
Weisskoff, R., Zuo, C. S., Boxerman, J. L., & Rosen, B. R. (1994) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910310605 · Cited by 715 · cited 1×
“Similarly, the x-axis of the size-dependence curves actually scales as R(2)/D, where R is the vessel size and D is the proton diffusion rate.(41) Therefore, decreasing D (restricted diffusion) has”
Self-citationVillringer, A., Rosen, B. R., Belliveau, J. W., Ackerman, J. L., Lauffer, R. B., Buxton, R. B., Chao, Y., Wedeenand, V. J., & Brady, T. J. (1988) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910060205 · Cited by 706 · cited 2×
“The DSC-MRI contrast mechanism is based upon compartmentalization of paramagnetic GBCA that establishes magnetic susceptibility difference between the intra- and extra-vascular space, creating magnetic field gradients.(32) Protons lose phase coherence as they diffuse through the transient, spatially varying gradients,…”
Self-citationBoxerman, J. L., Schmainda, K. M., & Weisskoff, R. M. (2006) · PubMed · Cited by 686
Self-citation
Cited by
Advances of MR imaging in glioma: What the neurosurgeon needs to know
Falk Delgado, A. (2025) · Acta Neurochirurgica · doi:10.1007/s00701-025-06593-6 · Cited by 14
Magnetic resonance imaging techniques for monitoring glioma response to chemoradiotherapy
Lawrence, L. S. P., Maralani, P. J., Das, S., Sahgal, A., Stanisz, G. J., & Lau, A. Z. (2025) · Journal of Neuro-Oncology · doi:10.1007/s11060-024-04856-3 · Cited by 4
Metadata
- Authors
- Boxerman, J. L., Quarles, C. C., Hu, L. S., Erickson, B. J., Gerstner, E. R., Smits, M., Kaufmann, T. J., Barboriak, D. P., Huang, R. H., Wick, W., Weller, M., Galanis, E., Kalpathy-Cramer, J., Shankar, L., Jacobs, P., Chung, C., van den Bent, M. J., Chang, S., Al Yung, W. K., Cloughesy, T. F., Wen, P. Y., Gilbert, M. R., Rosen, B. R., Ellingson, B. M., Schmainda, K. M., Jumpstarting Brain Tumor Drug Development Coalition Imaging Standardization Steering Committee, Arons, D. F., Kingston, A., Sandak, D., Wallace, M., Musella, A., & Haynes, C.
- Venue
- Neuro-Oncology
- Publisher
- Oxford University Press (OUP)
- Published
- 2020-06-09
- Volume
- 22
- Issue
- 9
- Pages
- 1262-1275
- ISSN
- 1522-8517 (ISSN-L)
- 1523-5866
- OpenAlex
- W3033939517
- Cited by
- 206
- References
- 68
- FWCI
- 12.10
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.