Consensus recommendations for a dynamic susceptibility contrast MRI protocol for use in high-grade gliomas
Open accessThe DOI matches its Crossref record; 68 of the 68 references it cites were found in a registry or an index.
Abstract
Despite the widespread clinical use of dynamic susceptibility contrast (DSC) MRI, DSC-MRI methodology has not been standardized, hindering its utilization for response assessment in multicenter trials. Recently, the DSC-MRI Standardization Subcommittee of the Jumpstarting Brain Tumor Drug Development Coalition issued an updated consensus DSC-MRI protocol compatible with the standardized brain tumor imaging protocol (BTIP) for high-grade gliomas that is increasingly used in the clinical setting and is the default MRI protocol for the National Clinical Trials Network. After reviewing the basis for controversy over DSC-MRI protocols, this paper provides evidence-based best practices for clinical DSC-MRI as determined by the Committee, including pulse sequence (gradient echo vs spin echo), BTIP-compliant contrast agent dosing (preload and bolus), flip angle (FA), echo time (TE), and post-processing leakage correction. In summary, full-dose preload, full-dose bolus dosing using intermediate (60°) FA and field strength-dependent TE (40–50 ms at 1.5 T, 20–35 ms at 3 T) provides overall best accuracy and precision for cerebral blood volume estimates. When single-dose contrast agent usage is desired, no-preload, full-dose bolus dosing using low FA (30°) and field strength-dependent TE provides excellent performance, with reduced contrast agent usage and elimination of potential systematic errors introduced by variations in preload dose and incubation time.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Wen, P. Y., Macdonald, D. R., Reardon, D. A., Cloughesy, T. F., Sorensen, A. G., Galanis, E., DeGroot, J., Wick, W., Gilbert, M. R., Lassman, A. B., et al. (2010) · Journal of Clinical Oncology · doi:10.1200/jco.2009.26.3541 · Cited by 3,836
Self-citationFunctional mapping of the human visual cortex by magnetic resonance imaging
Belliveau, J. W., Kennedy, D. N., McKinstry, R. C., Buchbinder, B. R., Weisskoff, R. M., Cohen, M. S., Vevea, J. M., Brady, T. J., & Rosen, B. R. (1991) · Science · doi:10.1126/science.1948051 · Cited by 1,883
Self-citationØstergaard, L., Weisskoff, R. M., Chesler, D. A., Gyldensted, C., & Rosen, B. R. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910360510 · Cited by 1,512
Self-citationOn the Theory of the Indicator-Dilution Method for Measurement of Blood Flow and Volume
Meier, P., & Zierler, K. L. (1954) · Journal of Applied Physiology · doi:10.1152/jappl.1954.6.12.731 · Cited by 1,274 · cited 1×
“DSC-MRI is based upon classical indicator dilution theory used by physiologists to quantitate hemodynamics of whole-organ systems from known quantities of injected non-diffusible tracers such as dyes and radiotracers, and measurement of output tracer concentration.(31) DSC-MRI applies this methodology to -MRI is a cqu…”
Perfusion imaging with NMR contrast agents
Rosen, B. R., Belliveau, J. W., Vevea, J. M., & Brady, T. J. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910140211 · Cited by 1,151 · cited 1×
“applyparastyle "fig//caption/p[1]" parastyle "FigCapt" applyparastyle "fig" parastyle "Figure"”
Self-citationMr contrast due to intravascular magnetic susceptibility perturbations
Boxerman, J. L., Hamberg, L. M., Rosen, B. R., & Weisskoff, R. M. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910340412 · Cited by 1,008 · cited 3×
“Protons lose phase coherence as they diffuse through the transient, spatially varying gradients, yielding signal attenuation dependent upon physiological factors, including vessel or compartment size and proton diffusion rate, and experimental factors, including pulse sequence parameters and contrast agent concentrati…”
Self-citationCerebral blood volume maps of gliomas: comparison with tumor grade and histologic findings.
Aronen, H. J., Gazit, I. E., Louis, D. N., Buchbinder, B. R., Pardo, F. S., Weisskoff, R. M., Harsh, G. R., Cosgrove, G. R., Halpern, E. F., & Hochberg, F. H. (1994) · Radiology · doi:10.1148/radiology.191.1.8134596 · Cited by 908 · cited 1×
“DSC-MRI -induced brain activation,(2) and produce the first MRI-based CBV maps of gliomas.(3) Since these beginnings, studies have shown that DSC-MRI may be more useful than standard MRI at predicting treatment-naïve glioma grade(3-8) and survival,(9-13) distinguishing post-treatment pseudoprogression and radiation ne…”
Microscopic susceptibility variation and transverse relaxation: Theory and experiment
Weisskoff, R., Zuo, C. S., Boxerman, J. L., & Rosen, B. R. (1994) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910310605 · Cited by 715 · cited 1×
“Similarly, the x-axis of the size-dependence curves actually scales as R(2)/D, where R is the vessel size and D is the proton diffusion rate.(41) Therefore, decreasing D (restricted diffusion) has”
Self-citationVillringer, A., Rosen, B. R., Belliveau, J. W., Ackerman, J. L., Lauffer, R. B., Buxton, R. B., Chao, Y., Wedeenand, V. J., & Brady, T. J. (1988) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910060205 · Cited by 706 · cited 2×
“The DSC-MRI contrast mechanism is based upon compartmentalization of paramagnetic GBCA that establishes magnetic susceptibility difference between the intra- and extra-vascular space, creating magnetic field gradients.(32) Protons lose phase coherence as they diffuse through the transient, spatially varying gradients,…”
Self-citationBoxerman, J. L., Schmainda, K. M., & Weisskoff, R. M. (2006) · PubMed · Cited by 686
Self-citationConsensus recommendations for a standardized Brain Tumor Imaging Protocol in clinical trials
(2015) · Neuro-Oncology · doi:10.1093/neuonc/nov095 · Cited by 663 · cited 4×
“Furthermore, the standardized BTIP requires post-contrast imaging after one total dose of GBCA.(30) Finally, gadolinium-based DSC-MRI permits measurement of additional physiological parameters related to GBCA extravasation, such as PSR (percent signal recovery of the signal-time curve compared to baseline), as well as…”
InfluentialRempp, K. A., Brix, G., Wenz, F., Becker, C. R., Gückel, F., & Lorenz, W. J. (1994) · Radiology · doi:10.1148/radiology.193.3.7972800 · Cited by 639
Cha, S., Knopp, E. A., Johnson, G., Wetzel, S. G., Litt, A. W., & Zagzag, D. (2002) · Radiology · doi:10.1148/radiol.2231010594 · Cited by 525 · cited 1×
“>20ms) can reduce T1 contamination due to GBCA extravasation.(44) However, some parameter combinations may also reduce the SNR of the computed rCBV maps,(67) and the goal is to minimize leakage effects while maintaining SNR.”
Barajas, R. F., Chang, J. S., Segal, M. R., Parsa, A. T., McDermott, M. W., Berger, M. S., & Cha, S. (2009) · Radiology · doi:10.1148/radiol.2532090007 · Cited by 407
Hu, L. S., Baxter, L. C., Smith, K. A., Feuerstein, B. G., Karis, J. P., Eschbacher, J. M., Coons, S. W., Nakaji, P., Yeh, R. F., Debbins, J., et al. (2009) · American Journal of Neuroradiology · doi:10.3174/ajnr.a1377 · Cited by 396
Self-citationPseudoprogression and pseudoresponse in the treatment of gliomas
Brandsma, D., & van den Bent, M. J. (2009) · Current Opinion in Neurology · doi:10.1097/wco.0b013e328332363e · Cited by 378
Self-citationFisel, C. R., Ackerman, J. L., Buxton, R. B., Garrido, L., Belliveau, J. W., Rosen, B. R., & Brady, T. J. (1991) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910170206 · Cited by 356 · cited 1×
“Although this behavior can be solved analytically for limited regimes, this phenomenon has been most generally studied using Monte Carlo numerical methods that quantify the relationship between change in relaxation rate and the physiological and experimental parameters.(36,37) These simulations yield the vessel size-d…”
Self-citationPaulson, E. S., & Schmainda, K. M. (2008) · Radiology · doi:10.1148/radiol.2492071659 · Cited by 327
Self-citationDas, S., & Marsden, P. A. (2013) · New England Journal of Medicine · doi:10.1056/nejmcibr1309402 · Cited by 268
Donahue, K. M., Krouwer, H. G. J., Rand, S. D., Pathak, A. P., Marszalkowski, C. S., Censky, S. C., & Prost, R. W. (2000) · Magnetic Resonance in Medicine · doi:10.1002/1522-2594(200006)43:6<845::aid-mrm10>3.0.co;2-j · Cited by 253 · cited 3×
“and there is ample evidence that post-processing leakage-correction of DSC-MRI data is necessary for accurate rCBV measurement when the BBB is disrupted.(5,8,45) A pharmacokinetic model-based approach described by Weisskoff et al.”
Patel, P., Baradaran, H., Delgado, D., Askin, G., Christos, P., John Tsiouris, A., & Gupta, A. (2017) · Neuro-Oncology · doi:10.1093/neuonc/now148 · Cited by 250
Welker, K., Boxerman, J., Kalnin, A., Kaufmann, T., Shiroishi, M., Wintermark, M., & for the American Society of Functional Neuroradiology MR Perfusion Standards and Practice Subcommittee of the ASFNR Clinical Practice Committee (2015) · American Journal of Neuroradiology · doi:10.3174/ajnr.a4341 · Cited by 243
Self-citationHu, L. S., Eschbacher, J. M., Heiserman, J. E., Dueck, A. C., Shapiro, W. R., Liu, S., Karis, J. P., Smith, K. A., Coons, S. W., Nakaji, P., et al. (2012) · Neuro-Oncology · doi:10.1093/neuonc/nos112 · Cited by 216
Self-citationSchmainda, K. M., Rand, S. D., Joseph, A. M., Lund, R., Ward, B. D., Pathak, A. P., Ulmer, J. L., Baddrudoja, M. A., Baddrudoja, M. A., & Krouwer, H. G. J. (2004) · PubMed Central · Cited by 197
Self-citationPrager, A. J., Martinez, N., Beal, K., Omuro, A., Zhang, Z., & Young, R. J. (2015) · American Journal of Neuroradiology · doi:10.3174/ajnr.a4218 · Cited by 193 · cited 1×
“3.(75) Other studies also found mean or median CBV to be predictive, with varying thresholds,(19,76) but others have found mean CBV to be non-predictive or only predictive with qualification.”
Kong, D.-S., Kim, S. T., Kim, E.-H., Lim, D. H., Kim, W. S., Suh, Y.-L., Lee, J.-I., Park, K., Kim, J. H., & Nam, D.-H. (2011) · American Journal of Neuroradiology · doi:10.3174/ajnr.a2286 · Cited by 192
Aronen, H. J., Pardo, F. S., Kennedy, D. N., Belliveau, J. W., Packard, S. D., Hsu, D. W., Hochberg, F., Fischman, A. J., & Rosen, B. R. (2000) · PubMed · Cited by 175
Self-citationMangla, R., Singh, G., Ziegelitz, D., Milano, M. T., Korones, D. N., Zhong, J., & Ekholm, S. E. (2010) · Radiology · doi:10.1148/radiol.10091440 · Cited by 171
Barajas, R. F., Hodgson, J. G., Chang, J. S., Vandenberg, S. R., Yeh, R.-F., Parsa, A. T., McDermott, M. W., Berger, M. S., Dillon, W. P., & Cha, S. (2010) · Radiology · doi:10.1148/radiol.09090663 · Cited by 168 · cited 1×
“Similarly, stereotactic biopsies co-registered to CBV maps made using no preload, a low FA (35°), and no model-based leakage correction also had good correlation of CBV with microvascular expression.(71) The literature is replete with conflicting acquisition strategies such as these.”
Tumor vascularity in the brain: evaluation with dynamic susceptibility-contrast MR imaging.
Maeda, M., Itoh, S., Kimura, H., Iwasaki, T., Hayashi, N., Yamamoto, K., Ishii, Y., & Kubota, T. (1993) · Radiology · doi:10.1148/radiology.189.1.8372199 · Cited by 167
Hu, L., Baxter, L. C., Pinnaduwage, D. S., Paine, T. L., Karis, J. P., Feuerstein, B. G., Schmainda, K. M., Dueck, A. C., Debbins, J. P., Smith, K. A., et al. (2009) · American Journal of Neuroradiology · doi:10.3174/ajnr.a1787 · Cited by 154 · cited 1×
“1 mmol/kg and an incubation time of 6 minutes between preload administration and bolus injection optimized the separation of CBVs for tumor and treatment effect in HGGs with recurrent enhancement after standard chemoradiation.(52)”
Self-citationSugahara, T., Korogi, Y., Kochi, M., Ushio, Y., & Takahashi, M. (2001) · PubMed · Cited by 144
Box, P. (2010) · International Journal of Medical Radiology · Cited by 140
MRI perfusion in determining pseudoprogression in patients with glioblastoma
Young, R. J., Gupta, A. K., Shah, A. D., Graber, J. J., Chan, T. A.-T., Zhang, Z., Shi, W., Beal, K. P., & Omuro, A. M. P. (2012) · Clinical Imaging · doi:10.1016/j.clinimag.2012.02.016 · Cited by 138
Schmainda, K. M., Prah, M. A., Connelly, J., Rand, S. D., Hoffman, R. G., Mueller, W. M., & Malkin, M. G. (2014) · Neuro-Oncology · doi:10.1093/neuonc/not216 · Cited by 132 · cited 1×
“RCBV measurements using preload and the BSW method agree well with histology in spatially correlated tissue biopsies,(58,59) and the BSW method has been applied in single-institution studies and multi-site clinical trials demonstrating, among other benefits, the utility of rCBV for predicting or detecting early respon…”
Self-citationSchmainda, K. M., Zhang, Z., Prah, M. A., Snyder, B. S., Gilbert, M. R., Sorensen, A. G., Barboriak, D. P., & Boxerman, J. L. (2015) · Neuro-Oncology · doi:10.1093/neuonc/nou364 · Cited by 130 · cited 1×
“RCBV measurements using preload and the BSW method agree well with histology in spatially correlated tissue biopsies,(58,59) and the BSW method has been applied in single-institution studies and multi-site clinical trials demonstrating, among other benefits, the utility of rCBV for predicting or detecting early respon…”
Self-citationWillats, L., & Calamante, F. (2012) · NMR in Biomedicine · doi:10.1002/nbm.2833 · Cited by 130 · cited 1×
“There are multiple protocol decisions for DSC-MRI that influence its practical implementation and the accuracy and precision of CBV measurement.(27) These”
Hu, L., Eschbacher, J. M., Dueck, A. C., Heiserman, J. E., Liu, S., Karis, J. P., Smith, K. A., Shapiro, W. R., Pinnaduwage, D. S., Coons, S. W., et al. (2011) · American Journal of Neuroradiology · doi:10.3174/ajnr.a2743 · Cited by 128
Self-citationACRIN 6684: Assessment of Tumor Hypoxia in Newly Diagnosed Glioblastoma Using 18F-FMISO PET and MRI
Gerstner, E. R., Zhang, Z., Fink, J. R., Muzi, M., Hanna, L., Greco, E., Prah, M., Schmainda, K. M., Mintz, A., Kostakoglu, L., et al. (2016) · Clinical Cancer Research · doi:10.1158/1078-0432.ccr-15-2529 · Cited by 122
Self-citationBoxerman, J. L., Prah, D. E., Paulson, E. S., Machan, J. T., Bedekar, D. P., & Schmainda, K. M. (2012) · American Journal of Neuroradiology · doi:10.3174/ajnr.a2934 · Cited by 119 · cited 1×
“For high FA, rCBV using preload plus leakage correction strongly correlates with tumor grade, whereas uncorrected rCBV does not,(8) and in a rat gliosarcoma model, combined preload and post-processing leakage correction yield CBV estimates that converge to gold standard values obtained using MION, an intravascular con…”
Self-citationBjørnerud, A., Sorensen, A. G., Mouridsen, K., & Emblem, K. E. (2011) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.2011.52 · Cited by 118
Combined spin‐ and gradient‐echo perfusion‐weighted imaging
Schmiedeskamp, H., Straka, M., Newbould, R. D., Zaharchuk, G., Andre, J. B., Olivot, J., Moseley, M. E., Albers, G. W., & Bammer, R. (2011) · Magnetic Resonance in Medicine · doi:10.1002/mrm.23195 · Cited by 109
Kim, H. S., Goh, M. J., Kim, N., Choi, C. G., Kim, S. J., & Kim, J. H. (2014) · Radiology · doi:10.1148/radiol.14132868 · Cited by 109
Signal‐to‐noise analysis of cerebral blood volume maps from dynamic NMR imaging studies
Boxerman, J. L., Rosen, B. R., & Weisskoff, R. M. (1997) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880070313 · Cited by 101 · cited 1×
“Number of baseline time points Because the number of baseline acquisitions impacts CBV map SNR, image acquisition should begin at least 30 50 time points before contrast injection via a power injector.(67)”
Self-citationKickingereder, P., Wiestler, B., Burth, S., Wick, A., Nowosielski, M., Heiland, S., Schlemmer, H.-P., Wick, W., Bendszus, M., & Radbruch, A. (2015) · Neuro-Oncology · doi:10.1093/neuonc/nov028 · Cited by 99
Self-citationGasparetto, E. L., Pawlak, M. A., Patel, S. H., Huse, J. T., Woo, J. H., Krejza, J., Rosenfeld, M. R., O’Rourke, D. M., Lustig, R. A., Melhem, E. R., et al. (2009) · Radiology · doi:10.1148/radiol.2502071444 · Cited by 92
Bedekar, D. P., Jensen, T. R., & Schmainda, K. M. (2010) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22445 · Cited by 89 · cited 1×
“Alternative methods precluding the need to normalize rCBV to reference brain include standardization and Gaussian normalization.(34,35)”
Self-citationAntiangiogenic effects of dexamethasone in 9L gliosarcoma assessed by MRI cerebral blood volume maps
Badruddoja, M. A., Krouwer, H. G. J., Rand, S. D., Rebro, K. J., Pathak, A. P., & Schmainda, K. M. (2003) · Neuro-Oncology · doi:10.1215/s1152851703000073 · Cited by 72
Self-citationPrah, M. A., Stufflebeam, S. M., Paulson, E. S., Kalpathy–Cramer, J., Gerstner, E. R., Batchelor, T. T., Barboriak, D. P., Rosen, B. R., & Schmainda, K. M. (2015) · American Journal of Neuroradiology · doi:10.3174/ajnr.a4374 · Cited by 70 · cited 1×
“RCBV measurements using preload and the BSW method agree well with histology in spatially correlated tissue biopsies,(58,59) and the BSW method has been applied in single-institution studies and multi-site clinical trials demonstrating, among other benefits, the utility of rCBV for predicting or detecting early respon…”
Self-citationBonekamp, D., Deike, K., Wiestler, B., Wick, W., Bendszus, M., Radbruch, A., & Heiland, S. (2015) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.24756 · Cited by 67
Self-citationQuarles, C. C., Gochberg, D. F., Gore, J. C., & Yankeelov, T. E. (2009) · Physics in Medicine and Biology · doi:10.1088/0031-9155/54/19/006 · Cited by 67 · cited 1×
“baseline as they do for ideal tracer kinetics, but extend below or above baseline depending on whether T1 or T2* effects dominate, thereby affecting the accuracy of CBV estimates determined from the area under the R2*-time curve.(43) The”
Self-citationSchmainda, K. M., Prah, M. A., Rand, S. D., Liu, Y., Logan, B. R., Muzi, M., Levendovszky, S. R., Da, X., Yen, Y., Kalpathy–Cramer, J., et al. (2018) · American Journal of Neuroradiology · doi:10.3174/ajnr.a5675 · Cited by 64
Self-citationKnutsson, L., Ståhlberg, F., & Wirestam, R. (2004) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2003.12.002 · Cited by 64
Schmainda, K. M., Prah, M. A., Hu, L., Quarles, C. C., Semmineh, N. B., Rand, S. D., Connelly, J., Anderies, B. J., Zhou, Y., Liu, Y., et al. (2019) · American Journal of Neuroradiology · doi:10.3174/ajnr.a6015 · Cited by 61
Self-citationImpact of Software Modeling on the Accuracy of Perfusion MRI in Glioma
Hu, L., Kelm, Z. S., Korfiatis, P. D., Dueck, A. C., Elrod, C., Ellingson, B. M., Kaufmann, T. J., Eschbacher, J. M., Karis, J. P., Smith, K., et al. (2015) · American Journal of Neuroradiology · doi:10.3174/ajnr.a4451 · Cited by 60 · cited 1×
“For instance, significantly different performance was observed when identical DSC-MRI data were processed with two software packages using different implementations of post-processing leakage correction.(62) The best correlation of CBV with histology”
Self-citationPrah, M. A., Al-Gizawiy, M. M., Mueller, W. M., Cochran, E. J., Hoffmann, R. G., Connelly, J., & Schmainda, K. M. (2017) · Journal of Neuro-Oncology · doi:10.1007/s11060-017-2617-3 · Cited by 53 · cited 1×
“13 with 82% sensitivity and 90% specificity.(59) Patel et al.”
Self-citationThree-dimensional observations on microvascular growth in rat glioma using a vascular casting method
Zama, A., Tamura, M., & INOUE, H. K. (1991) · Journal of Cancer Research and Clinical Oncology · doi:10.1007/bf01612757 · Cited by 51
Gahramanov, S., Muldoon, L. L., Li, X., & Neuwelt, E. A. (2011) · Radiology · doi:10.1148/radiol.11103503 · Cited by 50 · cited 1×
“Intravascular contrast agents like ferumoxytol eliminate contrast agent leakage effects entirely, and there is compelling evidence that ferumoxytol-based CBV measurements are inherently more accurate and precise than gadoliniumbased CBV measurements because complications related to GBCA extravasation are minimized.(50…”
Smith, M. R., Lu, H., & Frayne, R. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10330 · Cited by 48
Harris, R. J., Cloughesy, T. F., Hardy, A. J., Liau, L. M., Pope, W. B., Nghiemphu, P. L., Lai, A., & Ellingson, B. M. (2015) · Journal of Neuro-Oncology · doi:10.1007/s11060-015-1755-8 · Cited by 42
Self-citationLeu, K., Boxerman, J. L., Lai, A., Nghiemphu, P. L., Pope, W. B., Cloughesy, T. F., & Ellingson, B. M. (2016) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.25227 · Cited by 39
Self-citationSemmineh, N. B., Bell, L. C., Stokes, A. M., Hu, L., Boxerman, J. L., & Quarles, C. C. (2018) · American Journal of Neuroradiology · doi:10.3174/ajnr.a5827 · Cited by 38 · cited 4×
“5 T.(66) Confluent regions of high performance are desirable because these schemes would presumably be less sensitive to minor parameter variations or to underlying model assumptions or tumor physiology.”
InfluentialSelf-citationPaulson, E. S., Prah, D. E., & Schmainda, K. M. (2016) · Tomography · doi:10.18383/j.tom.2016.00217 · Cited by 38
Self-citationSemmineh, N. B., Xu, J., Skinner, J. T., Xie, J., Li, H., Ayers, G. D., & Quarles, C. C. (2014) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25435 · Cited by 37 · cited 1×
“12 and cell distribution.(28) Signal-time (and R2*-time) curves no longer return to”
Self-citationSemmineh, N. B., Stokes, A. M., Bell, L. C., Boxerman, J. L., & Quarles, C. C. (2017) · Tomography · doi:10.18383/j.tom.2016.00286 · Cited by 36 · cited 2×
“Therefore, implementation matters, motivating efforts to build consensus regarding post-processing and to establish a benchmark for validating DSC-MRI analysis tools, such as the DRO described below.(65,66)”
Self-citationLeu, K., Enzmann, D. R., Woodworth, D. C., Harris, R. J., Tran, A., Lai, A., Nghiemphu, P. L., Pope, W. B., Cloughesy, T. F., & Ellingson, B. M. (2014) · Cancer Imaging · doi:10.1186/s40644-014-0031-z · Cited by 27
Self-citationAquino, D., Stefano, A. L. D., Scotti, A., Cuppini, L., Anghileri, E., Finocchiaro, G., Bruzzone, M. G., & Eoli, M. (2014) · PLoS ONE · doi:10.1371/journal.pone.0090535 · Cited by 23
Horváth, A., Várallyay, C. G., Schwartz, D., Tóth, G. B., Netto, J. P., Barajas, R., Várallyay, P., Szidonya, L. K., Firkins, J. L., Youngers, E. H., et al. (2017) · Magnetic Resonance in Medicine · doi:10.1002/mrm.27028 · Cited by 9 · cited 1×
“Although conventional contrast-enhanced imaging is feasible with ferumoxytol, it is practically performed 24 hours after agent administration.(51) Furthermore, the standardized BTIP requires post-contrast imaging after one total dose of GBCA.”
Cited by
Advances of MR imaging in glioma: What the neurosurgeon needs to know
Falk Delgado, A. (2025) · Acta Neurochirurgica · doi:10.1007/s00701-025-06593-6 · Cited by 14
Magnetic resonance imaging techniques for monitoring glioma response to chemoradiotherapy
Lawrence, L. S. P., Maralani, P. J., Das, S., Sahgal, A., Stanisz, G. J., & Lau, A. Z. (2025) · Journal of Neuro-Oncology · doi:10.1007/s11060-024-04856-3 · Cited by 4
Metadata
- Authors
- Boxerman, J. L., Quarles, C. C., Hu, L. S., Erickson, B. J., Gerstner, E. R., Smits, M., Kaufmann, T. J., Barboriak, D. P., Huang, R. H., Wick, W., Weller, M., Galanis, E., Kalpathy-Cramer, J., Shankar, L., Jacobs, P., Chung, C., van den Bent, M. J., Chang, S., Al Yung, W. K., Cloughesy, T. F., Wen, P. Y., Gilbert, M. R., Rosen, B. R., Ellingson, B. M., Schmainda, K. M., Jumpstarting Brain Tumor Drug Development Coalition Imaging Standardization Steering Committee, Arons, D. F., Kingston, A., Sandak, D., Wallace, M., Musella, A., & Haynes, C.
- Venue
- Neuro-Oncology
- Publisher
- Oxford University Press (OUP)
- Published
- 2020-06-09
- Volume
- 22
- Issue
- 9
- Pages
- 1262-1275
- ISSN
- 1522-8517 (ISSN-L)
- 1523-5866
- OpenAlex
- W3033939517
- Cited by
- 206
- References
- 68
- FWCI
- 12.10
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.