Stereoelectroencephalography in the Presurgical Evaluation of Focal Epilepsy: A Retrospective Analysis of 215 Procedures
The DOI matches its OpenAlex record; 26 of the 26 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: To report on indications, surgical technique, results, and morbidity of stereoelectroencephalography (SEEG) in the presurgical evaluation of patients with drug-resistant focal epilepsy. METHODS: Two-hundred fifteen stereotactic implantations of multilead intracerebral electrodes were performed in 211 patients (4 patients were explored twice), who showed variable patterns of localizing incoherence among electrical (interictal/ictal scalp electroencephalography), clinical (ictal semeiology), and anatomic (magnetic resonance imaging [MRI]) investigations. MRI scanning showed a lesion in 134 patients (63%; associated with mesial temporal sclerosis in 7) and no lesion in 77 patients (37%; with mesial temporal sclerosis in 14 patients). A total of 2666 electrodes (mean, 12.4 per patient) were implanted (unilaterally in 175 procedures and bilaterally in 40). For electrode targeting, stereotactic stereoscopic cerebral angiograms were used in all patients, coupled with a coregistered three-dimensional MRI scan in 108 patients. RESULTS: One hundred eighty-three patients (87%) were scheduled for resective surgery after SEEG recording, and 174 have undergone surgery thus far. Resections sites were temporal in 47 patients (27%), frontal in 55 patients (31.6%), parietal in 14 patients (8%), occipital in one patient (0.6%), rolandic in one patient (0.6%), and multilobar in 56 patients (32.2%). Outcome on seizures (Engel's classification) in 165 patients with a follow-up period of more than 12 months was: Class I, 56.4%; Class II, 15.1%; Class III, 10.9%; and Class IV, 17.6%. Outcome was significantly associated with the results of MRI scanning (P = 0.0001) and with completeness of lesion removal (P = 0.038). Morbidity related to electrode implantation occurred in 12 procedures (5.6%), with severe permanent deficits from intracerebral hemorrhage in 2 (1%) patients. CONCLUSION: SEEG is a useful and relatively safe tool in the evaluation of surgical candidates when noninvasive investigations fail to localize the epileptogenic zone. SEEG-based resective surgery may provide excellent results in particularly complex drug-resistant epilepsies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Surgical Treatment of the Epilepsies
Kotagal, P. (1994) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-199407000-00009 · Cited by 2,747
Outcome with respect to epileptic seizures.
Engel, J. (1993) · Medical Entomology and Zoology · Cited by 2,338
Daumas-Duport, C., Scheithauer, B. W., Chodkiewicz, J.-P., Laws, E. R., & Vedrenne, C. (1988) · Neurosurgery · doi:10.1227/00006123-198811000-00002 · Cited by 719
Focal cortical dysplasia: neuropathological subtypes, EEG, neuroimaging and surgical outcome
Tassi, L. (2002) · Brain · doi:10.1093/brain/awf175 · Cited by 666
Self-citationChassoux, F. (2000) · Brain · doi:10.1093/brain/123.8.1733 · Cited by 391
Surgical and Neurological Complications in a Series of 708 Epilepsy Surgery Procedures
Behrens, E., Schramm, J., Zentner, J., & König, R. (1997) · Neurosurgery · doi:10.1097/00006123-199707000-00004 · Cited by 294
Complications of invasive video-EEG monitoring with subdural grid electrodes
Hamer, H. M., Morris, H. H., Mascha, E. J., Karafa, M. T., Bingaman, W. E., Bej, M. D., Burgess, R. C., Dinner, D. S., Foldvary, N. R., Hahn, J. F., et al. (2002) · Neurology · doi:10.1212/wnl.58.1.97 · Cited by 289
Potts, D. G. (1984) · Archives of Neurology · doi:10.1001/archneur.1984.04050230015009 · Cited by 272
Combined depth and subdural electrode investigation in uncontrolled epilepsy
Spencer, S. S., Spencer, D. D., Williamson, P. D., & Mattson, R. (1990) · Neurology · doi:10.1212/wnl.40.1.74 · Cited by 251
Stereotaxic Approach to Epilepsy
Talairach, J., & Bancaud, J. (2015) · Progress in Neurological Surgery · doi:10.1159/000394343 · Cited by 249
Cited by
Cardinale, F., Cossu, M., Castana, L., Casaceli, G., Schiariti, M. P., Miserocchi, A., Fuschillo, D., Moscato, A., Caborni, C., Arnulfo, G., et al. (2013) · Neurosurgery · doi:10.1227/neu.0b013e31827d1161 · Cited by 527
Self-citationMullin, J. P., Shriver, M., Alomar, S., Najm, I., Bulacio, J., Chauvel, P., & Gonzalez‐Martinez, J. (2016) · Epilepsia · doi:10.1111/epi.13298 · Cited by 434
Technique, Results, and Complications Related to Robot-Assisted Stereoelectroencephalography
González-Martínez, J., Bulacio, J., Thompson, S., Gale, J., Smithason, S., Najm, I., & Bingaman, W. (2016) · Neurosurgery · doi:10.1227/neu.0000000000001034 · Cited by 315
Stereoelectroencephalography in presurgical assessment of MRI-negative epilepsy
McGonigal, A., Bartolomei, F., Regis, J., Guye, M., Gavaret, M., Fonseca, A. T.-D., Dufour, H., Figarella-Branger, D., Girard, N., Peragut, J.-C., et al. (2007) · Brain · doi:10.1093/brain/awm218 · Cited by 290
Motor and emotional behaviours elicited by electrical stimulation of the human cingulate cortex
Caruana, F., Gerbella, M., Avanzini, P., Gozzo, F., Pelliccia, V., Mai, R., Abdollahi, R. O., Cardinale, F., Sartori, I., Lo Russo, G., et al. (2018) · Brain · doi:10.1093/brain/awy219 · Cited by 266
Self-citationThe Bancaud and Talairach view on the epileptogenic zone: a working hypothesis
Kahane, P., Landré, E., Minotti, L., Francione, S., & Ryvlin, P. (2006) · Epileptic Disorders · doi:10.1684/j.1950-6945.2006.tb00206.x · Cited by 212
Self-citationStereoelectroencephalography: retrospective analysis of 742 procedures in a single centre
Cardinale, F., Rizzi, M., Vignati, E., Cossu, M., Castana, L., d’Orio, P., Revay, M., Costanza, M. D., Tassi, L., Mai, R., et al. (2019) · Brain · doi:10.1093/brain/awz196 · Cited by 208
Self-citationBistability breaks-off deterministic responses to intracortical stimulation during non-REM sleep
Pigorini, A., Sarasso, S., Proserpio, P., Szymanski, C., Arnulfo, G., Casarotto, S., Fecchio, M., Rosanova, M., Mariotti, M., Lo Russo, G., et al. (2015) · NeuroImage · doi:10.1016/j.neuroimage.2015.02.056 · Cited by 200
“During the presurgical evaluation all patients underwent individual investigation with simultaneous single pulse electrical stimulation (SPES) and recordings performed by stereotactically implanted depth multi-lead electrodes (Stereo-EEG, SEEG) for the precise localization of the epileptogenic zone and connected areas…”
BackgroundMethodInfluentialSmall focal cortical dysplasia lesions are located at the bottom of a deep sulcus
Besson, P., Andermann, F., Dubeau, F., & Bernasconi, A. (2008) · Brain · doi:10.1093/brain/awn224 · Cited by 197
How Can We Identify Ictal and Interictal Abnormal Activity?
Fisher, R. S., Scharfman, H. E., & deCurtis, M. (2014) · Advances in Experimental Medicine and Biology · doi:10.1007/978-94-017-8914-1_1 · Cited by 193
Tandon, N., Tong, B. A., Friedman, E. R., Johnson, J. A., Von Allmen, G., Thomas, M. S., Hope, O. A., Kalamangalam, G. P., Slater, J. D., & Thompson, S. A. (2019) · JAMA Neurology · doi:10.1001/jamaneurol.2019.0098 · Cited by 191
Dissociated wake-like and sleep-like electro-cortical activity during sleep
Nobili, L., Ferrara, M., Moroni, F., De Gennaro, L., Russo, G. L., Campus, C., Cardinale, F., & De Carli, F. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2011.06.032 · Cited by 173
Self-citationFour-dimensional maps of the human somatosensory system
Avanzini, P., Abdollahi, R. O., Sartori, I., Caruana, F., Pelliccia, V., Casaceli, G., Mai, R., Lo Russo, G., Rizzolatti, G., & Orban, G. A. (2016) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1601889113 · Cited by 114
“Intracerebral recordings were performed according to sEEG methodology to define the cerebral structures involved in the onset and propagation of seizure activity (65, 66).”
MethodHippocampal sleep spindles preceding neocortical sleep onset in humans
Sarasso, S., Proserpio, P., Pigorini, A., Moroni, F., Ferrara, M., De Gennaro, L., De Carli, F., Lo Russo, G., Massimini, M., & Nobili, L. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2013.10.031 · Cited by 105
“France) (Cossu et al., 2005).”
InfluentialPothof, F., Bonini, L., Lanzilotto, M., Livi, A., Fogassi, L., Orban, G. A., Paul, O., & Ruther, P. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/4/046006 · Cited by 56
“This includes among others the monitoring of local field potentials (LFP) prior to the surgical treatment of focal epilepsy [2, 3], or deep brain stimulation in the case of Parkinson’s disease [4], multiple sclerosis related tremor [5], treatment of drug resistant depression [6], and the Tourette’s syndrome [7].”
BackgroundMultiple time courses of somatosensory responses in human cortex
Avanzini, P., Pelliccia, V., Lo Russo, G., Orban, G. A., & Rizzolatti, G. (2018) · NeuroImage · doi:10.1016/j.neuroimage.2017.12.037 · Cited by 49
Metadata
- Authors
- Cossu, M., Cardinale, F., Castana, L., Citterio, A., Francione, S., Tassi, L., Benabid, A. L., & Russo, G. L.
- Venue
- Neurosurgery
- Publisher
- Lippincott Williams & Wilkins
- Published
- 2005-10-01
- Volume
- 57
- Issue
- 4
- Pages
- 706-718
- ISSN
- 0148-396X (ISSN-L)
- OpenAlex
- W2056072423
- Cited by
- 332
- References
- 26
- FWCI
- 3.12
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.