CoChat

Characterization of Volatile Organic Compound Metabolites in Cigarette Smokers, Electronic Nicotine Device Users, Dual Users, and Nonusers of Tobacco

Open access
Keith, Rachel J, Fetterman, Jessica L, Orimoloye, Olusola A, Dardari, Zeina, Lorkiewicz, Pawel K, Hamburg, Naomi M, DeFilippis, Andrew P, Blaha, Michael J, Bhatnagar, Aruni · 2020 · Nicotine & Tobacco Research
Cited by 81

The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.

Abstract

Introduction: Limited research exists about the possible cardiovascular effects of electronic nicotine delivery systems (ENDS). We therefore sought to compare exposure to known or potentially cardiotoxic volatile organic compounds (VOCs) in ENDS users, smokers, and dual users. Methods: A total of 371 individuals from the Cardiovascular Injury due to Tobacco Use study, a cross-sectional study of healthy participants aged 21–45 years, were categorized as nonusers of tobacco (n = 87), sole ENDS users (n = 17), cigarette smokers (n = 237), and dual users (n = 30) based on 30-day self-reported tobacco product use patterns. Participants provided urine samples for VOC and nicotine metabolite measurement. We assessed associations between tobacco product use and VOC metabolite measures using multivariable-adjusted linear regression models. Results: Mean (SD) age of the population was 32 (±6.8) years, 55% men. Mean urinary cotinine level in nonusers of tobacco was 2.6 ng/mg creatinine, whereas cotinine levels were similar across all tobacco product use categories (851.6–910.9 ng/mg creatinine). In multivariable-adjusted models, sole ENDS users had higher levels of metabolites of acrolein, acrylamide, acrylonitrile, and xylene compared with nonusers of tobacco, but lower levels of most VOC metabolites compared with cigarette smokers or dual users. In direct comparison of cigarettes smokers and dual users, we found lower levels of metabolites of styrene and xylene in dual users. Conclusion: Although sole ENDS use may be associated with lower VOC exposure compared to cigarette smoking, further study is required to determine the potential health effects of the higher levels of certain reactive aldehydes, including acrolein, in ENDS users compared with nonusers of tobacco. Implications: ENDS use in conjunction with other tobacco products may not significantly reduce exposure to VOC, but sole use does generally reduce some VOC exposure and warrants more in-depth studies.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/ntr/ntz021

Cites

7 of 7 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 81

Metadata

Authors
Keith, R. J., Fetterman, J. L., Orimoloye, O. A., Dardari, Z., Lorkiewicz, P. K., Hamburg, N. M., DeFilippis, A. P., Blaha, M. J., & Bhatnagar, A.
Venue
Nicotine & Tobacco Research
Published
2019-02-13
Volume
22
Issue
2
Pages
264-272
ISSN
  • 1462-2203 (ISSN-L)
  • 1469-994X
OpenAlex
W2911913140
Cited by
81
References
7
FWCI
6.14
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.