CoChat

Solar simulated radiation induced cell death depends on spectral distribution and irradiance but not output delivery

Open access
Maguire, A., Lyng, F. M., Walsh, J. E. · 2010 · Radiation Protection Dosimetry

The DOI matches its Crossref record; 35 of the 36 references it cites were found in a registry or an index.

Abstract

Photo-biological investigations are dependent on calibration and characterisation to determine the relevance of an artificial irradiator to the study at hand. The importance of this has been voiced in the literature. However, the importance of output delivery is relatively unknown. The biological relevance of a high-energy, rapidly pulsing solar simulator was investigated using the clonogenic assay and was found to be reciprocity law compliant despite an exaggerated ultraviolet (UV) irradiance in excess of 1600 W m(-2) delivered per pulse. In fact, it was found to be the least cytotoxic irradiator compared with a second solar simulator and a UVB fluorescent lamp with continuous UV irradiances of 55 and 6.4 W m(-2), respectively. The reduced survival observed with the continuous irradiators is attributed to differences in spectral irradiance and distribution, particularly in the UVB, which in the absence of thorough calibration and characterisation may have resulted in erroneous conclusions.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/rpd/ncq080

Cites

35 of 36 references verified0 citation errors · 1 not checkable

Statistics

Figures

Figure 1 Spectral irradiance for the Q-sun solar simulator (a, ), the Oriel solar simulator operating at 35 mA (b, ), the UVA fluorescent lamp (c, ), and the UVB fluorescent lamp (d, ) at their respective exposure levels shown alongside solar irradiance sampled midsummer in Naples Italy 40 ° N (e, ) from 280 nm to 800 nm in (1A) and 280 nm to 400 nm in (1B). Also shown in (1B) are the irradiance spectra for solar radiation sampled midsummer in Albuquerque 38 ° N (f, ) and Melbourne 38 ° S (g , ) (30) .
Figure 1 Spectral irradiance for the Q-sun solar simulator (a, ), the Oriel solar simulator operating at 35 mA (b, ), the UVA fluorescent lamp (c, ), and the UVB fluorescent lamp (d, ) at their respective exposure levels shown alongside solar irradiance sampled midsummer in Naples Italy 40 ° N (e, ) from 280 nm to 800 nm in (1A) and 280 nm to 400 nm in (1B). Also shown in (1B) are the irradiance spectra for solar radiation sampled midsummer in Albuquerque 38 ° N (f, ) and Melbourne 38 ° S (g , ) (30) .CC-BY-NC-SA · From the PDF
Figure 2 Transmission spectra of cell culture medium ( ) and PBS ( ) measured using spectrally matched 1 cm quartz cuvettes in a dual beam PerkinElmer Lambda 900 UV/Vis/NIR spectrometer, where the reference cuvette contained deionised water.
Figure 2 Transmission spectra of cell culture medium ( ) and PBS ( ) measured using spectrally matched 1 cm quartz cuvettes in a dual beam PerkinElmer Lambda 900 UV/Vis/NIR spectrometer, where the reference cuvette contained deionised water.CC-BY-NC-SA · From the PDF
Figure 3 The irradiance spectra for the Q-sun solar simulator ( ), the Oriel solar simulator operating at 35 mA ( ), the UVA fluorescent lamp ( ) and the UVB fluorescent lamp ( ) at their respective exposure levels when transmitted through PBS (3A) and DMEM-F12 cell culture medium (3B).
Figure 3 The irradiance spectra for the Q-sun solar simulator ( ), the Oriel solar simulator operating at 35 mA ( ), the UVA fluorescent lamp ( ) and the UVB fluorescent lamp ( ) at their respective exposure levels when transmitted through PBS (3A) and DMEM-F12 cell culture medium (3B).CC-BY-NC-SA · From the PDF
Image 4
CC-BY-NC-SA · From the PDF
Image 5
CC-BY-NC-SA · From the PDF
Figure 6 Direct exposure of HaCaT cells in DMEM-F12 (6A) and PBS (6B) using the Q-sun ( ● ) and the Oriel ( O ) solar simulators; hexasterisk1 represents a significant difference between survival elicited by the two solar simulators for a given exposure duration, p ≤ 0.05
Figure 6 Direct exposure of HaCaT cells in DMEM-F12 (6A) and PBS (6B) using the Q-sun ( ● ) and the Oriel ( O ) solar simulators; hexasterisk1 represents a significant difference between survival elicited by the two solar simulators for a given exposure duration, p ≤ 0.05CC-BY-NC-SA · From the PDF
Figure 7 Direct exposure of HaCaT cells in DMEM-F12 cell culture medium ( ● ) and PBS ( O ) using the UVB fluorescent lamp, hexasterisk1 represents a significant difference between different exposure media for a given duration, p ≤ 0.05
Figure 7 Direct exposure of HaCaT cells in DMEM-F12 cell culture medium ( ● ) and PBS ( O ) using the UVB fluorescent lamp, hexasterisk1 represents a significant difference between different exposure media for a given duration, p ≤ 0.05CC-BY-NC-SA · From the PDF

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 36 references

Research works printed but not linked: 2

  1. IRPA Proposed change to the IRPA 1985 guidelines on limits of exposure to ultraviolet radiation. International Non-ionizing Radiation Committee of the International Radiation Protection Association. Health Phys. 56, 971-2 (1989).
  2. McKinlay, A. F. and Diffey, B. L. Reference action spectrum for ultraviolet induced erythema in human skin. CIE Journal. Volume 6, Pages 17-22 (1987).

Cited by

See all 6

Metadata

Authors
Maguire, A., Lyng, F. M., & Walsh, J. E.
Affiliations
Dublin Institute of Technology (IE)
Corresponding author
Maguire, A.
Venue
Radiation Protection Dosimetry
Published
2010-03-04
Volume
140
Issue
2
Pages
147-157
ISSN
  • 0144-8420 (ISSN-L)
  • 1742-3406
OpenAlex
W2029406960
Cited by
6
References
35
Citations by year
2023: 1 · 2021: 2 · 2020: 1 · 2013: 1
FWCI
0.52
Type
journal article
Language
en
Open access
Licence
cc-by-nc-sa
Locations
  • Radiation Protection Dosimetry (publishedVersion)
  • PubMed (publishedVersion)
  • Arrow - TU Dublin (Technological University Dublin) (submittedVersion, cc-by-nc-sa)
  • Arrow@dit (Dublin Institute of Technology) (submittedVersion, cc-by-nc-sa)
  • Arrow - TU Dublin (Technological University Dublin) (submittedVersion)
  • HighWire Press Open Archive (submittedVersion)
Funders
Deutsches Krebsforschungszentrum
Topics
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Effects of Radiation Exposure
  • Physical Sciences › Physics and Astronomy › Radiation › Radiation Therapy and Dosimetry
  • Physical Sciences › Physics and Astronomy › Radiation › Advanced Radiotherapy Techniques
Keywords
solar simulator, radiation-induced cell death, reciprocity laws, spectral irradiance distribution, irradiance, UV-B radiation, clonogenic survival
MeSH terms
Cells, Cultured, Colony-Forming Units Assay, Humans, Solar Energy, Ultraviolet Rays, Keratinocytes, Cell Death, Photobiology

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.