The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
The Use of Auto-Titrating Continuous Positive Airway Pressure for Treatment of Adult Obstructive Sleep Apnea
Abstract
This paper reviews the efficacy of auto-titrating continuous positive airway pressure (APAP) for treatment of obstructive sleep apnea. It is based on a review of 30 articles published in peer review journals conducted by a task force appointed by the American Academy of Sleep Medicine to develop practice parameters for use of APAP devices for treatment of obstructive sleep apnea (OSA). The data indicate that APAP can be used to treat many patients with OSA (auto-adjusting) or to identify an effective optimal fixed level of continuous positive airway pressure (CPAP) for treatment (auto-titration). Patients with significant congestive heart failure, chronic obstructive pulmonary disease (COPD), or significant amounts of central apnea were excluded from many treatment trials and there is insufficient evidence that APAP can be used to treat these patients. Many clinical trials have been performed in patients already on CPAP or with the initial APAP night in a laboratory setting. At this time only a few studies have evaluated initial titration with APAP in CPAP-naïve patients in an unattended setting. Further studies of APAP in this circumstance are needed. No studies have systematically compared the efficacy of one APAP technology with another. Devices using different technology may not give the same results in a given patient. Devices solely dependent on vibration may not work in non-snorers or patient who have undergone upper-airway surgery. High mask or mouth leaks may prevent adequate titration in devices monitoring snoring, flow, or impedance (forced oscillation technique). Review of the raw data to identify periods of high leak was performed in several of the APAP titration studies, to identify a pressure for fixed CPAP treatment or to determine if the titration was adequate. There is conflicting evidence for and against the premise that treatment with APAP increases acceptance and adherence compared to fixed CPAP. In studies demonstrating an increase in adherence with APAP, there was similar improvement in measures of daytime sleepiness as with fixed CPAP treatment. Further studies are needed to determine if APAP can increase acceptance or adherence with positive pressure treatment in patients with OSA.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Occurrence of Sleep-Disordered Breathing among Middle-Aged Adults
Young, T., Palta, M., Dempsey, J., Skatrud, J., Weber, S., & Badr, S. (1993) · New England Journal of Medicine · doi:10.1056/nejm199304293281704 · Cited by 10,183
Sullivan, C., Berthon-Jones, M., Issa, F., & Eves, L. (1981) · The Lancet · doi:10.1016/s0140-6736(81)92140-1 · Cited by 2,731
Jenkinson, C., Davies, R. J., Mullins, R., & Stradling, J. R. (1999) · The Lancet · doi:10.1016/s0140-6736(98)10532-9 · Cited by 826
Autoadjusting CPAP Therapy Based on Impedance Efficacy, Compliance and Acceptance
RANDERATH, W. J., SCHRAEDER, O., GALETKE, W., FELDMEYER, F., & RÜHLE, K.-H. (2001) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.163.3.2006168 · Cited by 143
Hudgel, D. W., & Fung, C. (2000) · Sleep · doi:10.1093/sleep/23.5.1g · Cited by 112
CPAP Titration for Sleep Apnea Using a Split-Night Protocol
Yamashiro, Y., & Kryger, M. H. (1995) · Chest · doi:10.1378/chest.107.1.62 · Cited by 104
Cited by
Meschia, J. F., Bushnell, C., Boden-Albala, B., Braun, L. T., Bravata, D. M., Chaturvedi, S., Creager, M. A., Eckel, R. H., Elkind, M. S. V., Fornage, M., et al. (2014) · Stroke · doi:10.1161/str.0000000000000046 · Cited by 2,650
Task Force Members, Kushida, C. A., Chediak, A., Berry, R. B., Brown, L. K., Gozal, D., Iber, C., Parthasarathy, S., Quan, S. F., & Rowley, J. A. (2008) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.27133 · Cited by 749
Self-citationChesson, A. L., Berry, R. B., & Pack, A. (2003) · Sleep · doi:10.1093/sleep/26.7.907 · Cited by 344
Obesity and obstructive sleep apnea
Gami, A. S., Caples, S. M., & Somers, V. K. (2003) · Endocrinology and Metabolism Clinics of North America · doi:10.1016/s0889-8529(03)00069-0 · Cited by 338
Morgenthaler, T. I., Aurora, R. N., Brown, T., Zak, R., Alessi, C., Boehlecke, B., Chesson, A. L., Friedman, L., Kapur, V., Maganti, R., et al. (2008) · Sleep · doi:10.1093/sleep/31.1.141 · Cited by 334
Metadata
- Venue
- Sleep
- Publisher
- Oxford University Press (OUP)
- Published
- 2002-01-01
- Volume
- 25
- Issue
- 2
- Pages
- 148-73
- ISSN
- 0161-8105 (ISSN-L)
- 1550-9109
- OpenAlex
- W2395816504
- Cited by
- 185
- References
- 6
- FWCI
- 8.08
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.