An Electrocardiogram-Based Technique to Assess Cardiopulmonary Coupling During Sleep
The DOI matches its Crossref record; 38 of the 38 references it cites were found in a registry or an index.
Abstract
STUDY OBJECTIVES: To evaluate a new automated measure of cardiopulmonary coupling during sleep using a single-lead electrocardiographic signal. DESIGN: Using training and test datasets of 35 polysomnograms each, we assessed the correlations of an electrocardiogram-based measure of cardiopulmonary interactions with respect to standard sleep staging, as well as to the cyclic alternating pattern classification. The pattern of coupling in 15 healthy individuals was also assessed. SETTING: American Academy of Sleep Medicine Accredited Sleep Disorders Center. INTERVENTIONS: None. MEASUREMENTS AND RESULTS: From a continuous, single-lead electrocardiogram, we extracted both the normal-to-normal sinus interbeat interval series and a corresponding electrocardiogram-derived respiration signal. Employing Fourier-based techniques, the product of the coherence and cross-power of these 2 simultaneous signals was used to generate a spectrographic representation of cardiopulmonary coupling dynamics during sleep. This technique shows that non-rapid eye movement sleep in adults demonstrates spontaneous abrupt transitions between high- and low-frequency cardiopulmonary coupling regimes, which have characteristic electroencephalogram, respiratory, and heart-rate variability signatures in both health and disease. Using the kappa statistic, agreement with standard sleep staging was poor (training set 62.7%, test set 43.9%) but higher with cyclic alternating pattern scoring (training set 74%, test set 77.3%). CONCLUSIONS: A sleep spectrogram derived from information in a single-lead electrocardiogram can be used to dynamically track cardiopulmonary interactions. The 2 distinct (bimodal) regimes demonstrate a closer relationship with visual cyclic alternating pattern and non-cyclic alternating pattern states than with standard sleep stages. This technique may provide a complementary approach to the conventional characterization of graded non-rapid eye movement sleep stages.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Goldberger, A. L., Amaral, L. A. N., Glass, L., Hausdorff, J. M., Ivanov, P. C., Mark, R. G., Mietus, J. E., Moody, G. B., Peng, C.-K., & Stanley, H. E. (2000) · Circulation · doi:10.1161/01.cir.101.23.e215 · Cited by 14,809
Self-citationTerzano, M. G., Parrino, L., Sherieri, A., Chervin, R., Chokroverty, S., Guilleminault, C., Hirshkowitz, M., Mahowald, M., Moldofsky, H., Rosa, A., et al. (2001) · Sleep Medicine · doi:10.1016/s1389-9457(01)00149-6 · Cited by 793
Self-citationThe effects of age, sex, ethnicity, and sleep-disordered breathing on sleep architecture
Redline, S., Kirchner, H. L., Quan, S. F., Gottlieb, D. J., Kapur, V., & Newman, A. (2004) · Archives of Internal Medicine · doi:10.1001/archinte.164.4.406 · Cited by 732
Lieberman, H., Tharion, W., Shukitt-Hale, B., Speckman, K., & Tulley, R. (2002) · Psychopharmacology · doi:10.1007/s00213-002-1217-9 · Cited by 576
The nature of arousal in sleep
Halász, P., Terzano, M., Parrino, L., & Bódizs, R. (2004) · Journal of Sleep Research · doi:10.1111/j.1365-2869.2004.00388.x · Cited by 529
Penzel, T., Kantelhardt, J. W., Grote, L., Peter, J., & Bunde, A. (2003) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.817636 · Cited by 492
Penzel, T., McNames, J., de Chazal, P., Raymond, B., Murray, A., & Moody, G. (2002) · Medical and Biological Engineering and Computing · doi:10.1007/bf02345072 · Cited by 417
Reliability of Scoring Respiratory Disturbance Indices and Sleep Staging
Whitney, C. W., Gottlieb, D. J., Redline, S., Norman, R. G., Dodge, R. R., Shahar, E., Surovec, S., & Nieto, F. J. (1998) · Sleep · doi:10.1093/sleep/21.7.749 · Cited by 327
Origin and Significance of the Cyclic Alternating Pattern (CAP)
Terzano, M. G., & Parrino, L. (2000) · Sleep Medicine Reviews · doi:10.1053/smrv.1999.0083 · Cited by 294
Screening of Obstructive Sleep Apnea Syndrome by Heart Rate Variability Analysis
Roche, F., Gaspoz, J.-M., Court-Fortune, I., Minini, P., Pichot, V., Duverney, D., Costes, F., Lacour, J.-R., & Barthélémy, J.-C. (1999) · Circulation · doi:10.1161/01.cir.100.13.1411 · Cited by 239
Cited by
Cyclic alternating pattern (CAP): The marker of sleep instability
Parrino, L., Ferri, R., Bruni, O., & Terzano, M. G. (2012) · Sleep Medicine Reviews · doi:10.1016/j.smrv.2011.02.003 · Cited by 442
Phenotypes in obstructive sleep apnea: A definition, examples and evolution of approaches
Zinchuk, A. V., Gentry, M. J., Concato, J., & Yaggi, H. K. (2017) · Sleep Medicine Reviews · doi:10.1016/j.smrv.2016.10.002 · Cited by 350
Scaling Up Scientific Discovery in Sleep Medicine: The National Sleep Research Resource
Dean, D. A., Goldberger, A. L., Mueller, R., Kim, M., Rueschman, M., Mobley, D., Sahoo, S. S., Jayapandian, C. P., Cui, L., Morrical, M. G., et al. (2016) · Sleep · doi:10.5665/sleep.5774 · Cited by 309
Self-citationIn situ monitoring of health in older adults: technologies and issues
Kang, H. G., Mahoney, D. F., Hoenig, H., Hirth, V. A., Bonato, P., Hajjar, I., Lipsitz, L. A., & for the Center for Integration of Medicine and Innovative Technology Working Group on Advanced Approaches to Physiologic Monitoring for the Aged (2010) · Journal of the American Geriatrics Society · doi:10.1111/j.1532-5415.2010.02959.x · Cited by 227
A review of signals used in sleep analysis
Roebuck, A., Monasterio, V, Gederi, E., Osipov, M., Behar, J., Malhotra, A., Penzel, T., & Clifford, G. D. (2014) · Physiological Measurement · doi:10.1088/0967-3334/35/1/r1 · Cited by 223
Consumer Sleep Technologies: A Review of the Landscape
Ko, P.-R. T., Kientz, J. A., Choe, E. K., Kay, M., Landis, C. A., & Watson, N. F. (2015) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.5288 · Cited by 211
The 2023 wearable photoplethysmography roadmap
Charlton, P. H., Allen, J., Bailón, R., Baker, S., Behar, J. A., Chen, F., Clifford, G. D., Clifton, D. A., Davies, H. J., Ding, C., et al. (2023) · Physiological Measurement · doi:10.1088/1361-6579/acead2 · Cited by 187
Recent Developments in Home Sleep-Monitoring Devices
Kelly, J. M., Strecker, R. E., & Bianchi, M. T. (2012) · ISRN Neurology · doi:10.5402/2012/768794 · Cited by 180
“Although the Zeo algorithm assigns greater weight in their sleep quality index to this stage of sleep, there is little evidence in the literature that the amount of “deep” sleep correlates with feeling refreshed.”
BackgroundModulations of Heart Rate, ECG, and Cardio-Respiratory Coupling Observed in Polysomnography
Penzel, T., Kantelhardt, J. W., Bartsch, R. P., Riedl, M., Kraemer, J. F., Wessel, N., Garcia, C., Glos, M., Fietze, I., & Schöbel, C. (2016) · Frontiers in Physiology · doi:10.3389/fphys.2016.00460 · Cited by 174
“Another technique to evaluate cardiopulmonary coupling during sleep solely utilizes continuous ECG signals and derives the HRV (e.g., RR interval time series) as well as fluctuations in R-wave amplitude induced by respiration (Thomas et al., 2005).”
BackgroundMethodInfluentialReal-Time Monitoring of Respiration Rhythm and Pulse Rate During Sleep
Zhu, X., Chen, W., Nemoto, T., Kanemitsu, Y., Kitamura, K., Yamakoshi, K., & Wei, D. (2006) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.884641 · Cited by 171
“884641 treatment of disorders like sleep apnea, sudden death syndrome [2], and heart diseases [3]–[5].”
BackgroundHang, L.-W., Wang, H.-L., Chen, J.-H., Hsu, J.-C., Lin, H.-H., Chung, W.-S., & Chen, Y.-F. (2015) · BMC Pulmonary Medicine · doi:10.1186/s12890-015-0017-z · Cited by 115
“Study limitations Unlike PSG and single-lead ECG, the limitation of oximetry measurement is that it is unable to score sleep quality [45].”
BackgroundSleep Abnormalities in Chronic Fatigue Syndrome/Myalgic Encephalomyelitis: A Review
Jackson, M. L., & Bruck, D. (2012) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.2276 · Cited by 106
Reinventing polysomnography in the age of precision medicine
Lim, D. C., Mazzotti, D. R., Sutherland, K., Mindel, J. W., Kim, J., Cistulli, P. A., Magalang, U. J., Pack, A. I., de Chazal, P., & Penzel, T. (2020) · Sleep Medicine Reviews · doi:10.1016/j.smrv.2020.101313 · Cited by 91
Thomas, R. J., Mietus, J. E., Peng, C.-K., Guo, D., Gozal, D., Montgomery-Downs, H., Gottlieb, D. J., Wang, C.-Y., & Goldberger, A. L. (2014) · Sleep Medicine · doi:10.1016/j.sleep.2013.10.002 · Cited by 90
“The CPC analysis of the ECG signal was performed as previously described in detail [13].”
Self-citationIbrahim, L. H., Jacono, F. J., Patel, S. R., Thomas, R. J., Larkin, E. K., Mietus, J. E., Peng, C.-K., Goldberger, A. L., & Redline, S. (2010) · Sleep · doi:10.1093/sleep/33.5.643 · Cited by 35
Self-citationSchramm, P. J., Zobel, I., Mönch, K., Schramm, E., & Michalak, J. (2016) · Sleep Medicine · doi:10.1016/j.sleep.2015.09.022 · Cited by 20
Metadata
- Authors
- Thomas, R. J., Mietus, J. E., Peng, C.-K., & Goldberger, A. L.
- Venue
- Sleep
- Publisher
- Oxford University Press (OUP)
- Published
- 2005-09
- Volume
- 28
- Issue
- 9
- Pages
- 1151-1161
- ISSN
- 0161-8105 (ISSN-L)
- 1550-9109
- OpenAlex
- W1495579528
- Cited by
- 335
- References
- 38
- FWCI
- 3.61
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.