The DOI matches its Crossref record.
Two‐photon molecular excitation provides intrinsic 3‐dimensional resolution for laser‐based microscopy and microphotochemistry
Abstract
With the development of sensitive and specific fluorescent indicators, modern laser scanning microscopies enable visualization and measurement of submicron, dynamic processes inside living cells and tissues. Here we describe the working principles of new, nonlinear laser microscopies based on two‐photon molecular excitation. In these techniques, a pulsed laser produces peak photon densities high enough that when focused into an appropriate medium, excitation by photon energy combinations can occur. For example, two red photons interacting simultaneously with a fluorescent molecule can excite within it a UV electronic transition, one corresponding to twice the energy of each single photon. Because the amount of two‐photon excitation depends on the square of the local illumination intensity, this process exhibits a unique localization to the diffraction‐limited spot of the beam focus. Elsewhere along the beam, excitation of background and photodamage is virtually nonexistent. Focal point localization of two‐photon excitation lends to all visualization, measurement, and photopharmacology studies an intrinsic, three‐dimensional resolution. We describe some preliminary biological applications, specifically, imaging of vital DNA stains in developing cells and embryos, imaging of cellular metabolic activity from NADH autofluorescence, spatially resolved measurements of cytoplasmic calcium ion activity, and optically induced micropharmacology using caged bioeffector molecules.—Williams, R. M., Piston, D. W., Webb, W. W. Two‐photon molecular excitation provides intrinsic three‐dimensional resolution for laser‐based microscopy and microphotochemistry. FASEB J. 8: 804‐813; 1994.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Precise Nanometer Localization Analysis for Individual Fluorescent Probes
Thompson, R. E., Larson, D. R., & Webb, W. W. (2002) · Biophysical Journal · doi:10.1016/s0006-3495(02)75618-x · Cited by 2,320
Self-citationDesign of Organic Molecules with Large Two-Photon Absorption Cross Sections
Albota, M., Beljonne, D., Brédas, J.-L., Ehrlich, J. E., Fu, J.-Y., Heikal, A. A., Hess, S. E., Kogej, T., Levin, M. D., Marder, S. R., et al. (1998) · Science · doi:10.1126/science.281.5383.1653 · Cited by 2,245
Self-citationMultiphoton fluorescence excitation: new spectral windows for biological nonlinear microscopy.
Xu, C., Zipfel, W., Shear, J. B., Williams, R. M., & Webb, W. W. (1996) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.93.20.10763 · Cited by 1,165
Self-citationTwo-Photon Excitation Fluorescence Microscopy
So, P. T. C., Dong, C. Y., Masters, B. R., & Berland, K. M. (2000) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.2.1.399 · Cited by 1,057
Measurement of Intracellular Calcium
Takahashi, A., Camacho, P., Lechleiter, J. D., & Herman, B. (1999) · Physiological Reviews · doi:10.1152/physrev.1999.79.4.1089 · Cited by 763
Metadata
- Authors
- Williams, R. M., Piston, D. W., & Webb, W. W.
- Venue
- The FASEB Journal
- Publisher
- Wiley
- Published
- 1994-08
- Volume
- 8
- Issue
- 11
- Pages
- 804-813
- ISSN
- 0892-6638 (ISSN-L)
- 1530-6860
- OpenAlex
- W2155757349
- Cited by
- 235
- References
- 0
- FWCI
- 9.04
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Two‐photon molecular excitation provides intrinsic 3‐dimensional resolution for laser‐based microscopy and microphotochemistry. https://app.cochat.ai/papers/10.1096/fasebj.8.11.8070629
- The paper
- Williams, R. M., Piston, D. W., & Webb, W. W. (1994). Two‐photon molecular excitation provides intrinsic 3‐dimensional resolution for laser‐based microscopy and microphotochemistry. The FASEB Journal. https://doi.org/10.1096/fasebj.8.11.8070629
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.