Two‐photon molecular excitation provides intrinsic 3‐dimensional resolution for laser‐based microscopy and microphotochemistry
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
With the development of sensitive and specific fluorescent indicators, modern laser scanning microscopies enable visualization and measurement of submicron, dynamic processes inside living cells and tissues. Here we describe the working principles of new, nonlinear laser microscopies based on two‐photon molecular excitation. In these techniques, a pulsed laser produces peak photon densities high enough that when focused into an appropriate medium, excitation by photon energy combinations can occur. For example, two red photons interacting simultaneously with a fluorescent molecule can excite within it a UV electronic transition, one corresponding to twice the energy of each single photon. Because the amount of two‐photon excitation depends on the square of the local illumination intensity, this process exhibits a unique localization to the diffraction‐limited spot of the beam focus. Elsewhere along the beam, excitation of background and photodamage is virtually nonexistent. Focal point localization of two‐photon excitation lends to all visualization, measurement, and photopharmacology studies an intrinsic, three‐dimensional resolution. We describe some preliminary biological applications, specifically, imaging of vital DNA stains in developing cells and embryos, imaging of cellular metabolic activity from NADH autofluorescence, spatially resolved measurements of cytoplasmic calcium ion activity, and optically induced micropharmacology using caged bioeffector molecules.—Williams, R. M., Piston, D. W., Webb, W. W. Two‐photon molecular excitation provides intrinsic three‐dimensional resolution for laser‐based microscopy and microphotochemistry. FASEB J. 8: 804‐813; 1994.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Principles of Fluorescence Spectroscopy
Lakowicz, J. R. (1999) · Springer eBooks · doi:10.1007/978-1-4757-3061-6 · Cited by 26,947
Two-photon laser scanning fluorescence microscopy
Denk, W., Strickler, J. H., & Webb, W. W. (1990) · Science · doi:10.1126/science.2321027 · Cited by 9,488
Self-citation
Cited by
Precise Nanometer Localization Analysis for Individual Fluorescent Probes
Thompson, R. E., Larson, D. R., & Webb, W. W. (2002) · Biophysical Journal · doi:10.1016/s0006-3495(02)75618-x · Cited by 2,320
“The intrinsic three-dimensional resolution and localization of the excitation volume (Williams et al., 1994) significantly reduces the extra noise caused by fluorescence from immersion oil, scattering inside the microscope, or parts of the cell out of the focal plane.”
BackgroundSelf-citationDesign of Organic Molecules with Large Two-Photon Absorption Cross Sections
Albota, M., Beljonne, D., Brédas, J.-L., Ehrlich, J. E., Fu, J.-Y., Heikal, A. A., Hess, S. E., Kogej, T., Levin, M. D., Marder, S. R., et al. (1998) · Science · doi:10.1126/science.281.5383.1653 · Cited by 2,245
Self-citationMultiphoton fluorescence excitation: new spectral windows for biological nonlinear microscopy.
Xu, C., Zipfel, W., Shear, J. B., Williams, R. M., & Webb, W. W. (1996) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.93.20.10763 · Cited by 1,165
Self-citationTwo-Photon Excitation Fluorescence Microscopy
So, P. T. C., Dong, C. Y., Masters, B. R., & Berland, K. M. (2000) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.2.1.399 · Cited by 1,057
Measurement of Intracellular Calcium
Takahashi, A., Camacho, P., Lechleiter, J. D., & Herman, B. (1999) · Physiological Reviews · doi:10.1152/physrev.1999.79.4.1089 · Cited by 763
Schwille, P., Haupts, U., Maiti, S., & Webb, W. W. (1999) · Biophysical Journal · doi:10.1016/s0006-3495(99)77065-7 · Cited by 722
Self-citationFuruta, T., Wang, S. S.-H., Dantzker, J. L., Dore, T. M., Bybee, W. J., Callaway, E. M., Denk, W., & Tsien, R. Y. (1999) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.96.4.1193 · Cited by 635
Exchange of Protein Molecules Through Connections Between Higher Plant Plastids
Köhler, R. H., Cao, J., Zipfel, W. R., Webb, W. W., & Hanson, M. R. (1997) · Science · doi:10.1126/science.276.5321.2039 · Cited by 582
Self-citationLong-term two-photon fluorescence imaging of mammalian embryos without compromising viability
Squirrell, J. M., Wokosin, D. L., White, J. G., & Bavister, B. D. (1999) · Nature Biotechnology · doi:10.1038/11698 · Cited by 538
Large-scale oscillatory calcium waves in the immature cortex
Garaschuk, O., Linn, J., Eilers, J., & Konnerth, A. (2000) · Nature Neuroscience · doi:10.1038/74823 · Cited by 493
Centonze, V. E., & White, J. G. (1998) · Biophysical Journal · doi:10.1016/s0006-3495(98)77643-x · Cited by 460
Intracellular Coenzymes as Natural Biomarkers for Metabolic Activities and Mitochondrial Anomalies
Heikal, A. A. (2010) · Biomarkers in Medicine · doi:10.2217/bmm.10.1 · Cited by 458
Highly Nonlinear Photodamage in Two-Photon Fluorescence Microscopy
Hopt, A., & Neher, E. (2001) · Biophysical Journal · doi:10.1016/s0006-3495(01)76173-5 · Cited by 442
“This damage seems to be quite nonlinear in nature, because, below this threshold, two-photon excitation is very favorable for cell viability, as has been pointed out repeatedly (e.g., Denk et al., 1990; Williams et al., 1994).”
BackgroundMeasuring Serotonin Distribution in Live Cells with Three-Photon Excitation
Maiti, S., Shear, J. B., Williams, R. M., Zipfel, W. R., & Webb, W. W. (1997) · Science · doi:10.1126/science.275.5299.530 · Cited by 417
Self-citationMultiphoton microscopy in biological research
Williams, R. M., Zipfel, W. R., & Webb, W. W. (2001) · Current Opinion in Chemical Biology · doi:10.1016/s1367-5931(00)00241-6 · Cited by 370
Self-citationImaging in vivo: watching the brain in action
Kerr, J. N. D., & Denk, W. (2008) · Nature Reviews Neuroscience · doi:10.1038/nrn2338 · Cited by 346
Two-photon fluorescence excitation and related techniques in biological microscopy
Diaspro, A., Chirico, G., & Collini, M. (2005) · Quarterly Reviews of Biophysics · doi:10.1017/s0033583505004129 · Cited by 318
Chung, H. J., Huang, Y. H., Lau, L.-F., & Huganir, R. L. (2004) · The Journal of Neuroscience · doi:10.1523/jneurosci.0546-04.2004 · Cited by 313
Yu, Q., & Heikal, A. A. (2009) · Journal of Photochemistry and Photobiology B: Biology · doi:10.1016/j.jphotobiol.2008.12.010 · Cited by 288
Two-Photon Photosensitized Production of Singlet Oxygen
Frederiksen, P. K., Jørgensen, M., & Ogilby, P. R. (2001) · Journal of the American Chemical Society · doi:10.1021/ja003468a · Cited by 258
Translocation and Utilization of Fungal Storage Lipid in the Arbuscular Mycorrhizal Symbiosis
Bago, B., Zipfel, W., Williams, R. M., Jun, J., Arreola, R., Lammers, P. J., Pfeffer, P. E., & Shachar-Hill, Y. (2002) · Plant Physiology · doi:10.1104/pp.010466 · Cited by 257
Self-citationMegason, S. G., & Fraser, S. E. (2007) · Cell · doi:10.1016/j.cell.2007.08.031 · Cited by 254
Nan, X., Potma, E. O., & Xie, X. S. (2006) · Biophysical Journal · doi:10.1529/biophysj.105.074534 · Cited by 224
Single-molecule fluorescence detection in microfluidic channels—the Holy Grail in μTAS?
Dittrich, P. S., & Manz, A. (2005) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-005-3335-9 · Cited by 182
A simple introduction to multiphoton microscopy
USTIONE, A., & PISTON, D. W. (2011) · Journal of Microscopy · doi:10.1111/j.1365-2818.2011.03532.x · Cited by 174
“Thus, in practice two-photon microscopy provides spatial resolution that is nearly identical to confocal microscopy (Williams et al., 1994).”
BackgroundInfluentialSelf-citationFluorescence correlation spectroscopy for the detection and study of single molecules in biology
Medina, M. Á., & Schwille, P. (2002) · BioEssays · doi:10.1002/bies.10118 · Cited by 166
“This feature, as well as the higher tolerance of infrared light by cells, makes two-photon excitation laser scanning microscopy an attractive alternative to confocal imaging.((45))Although two-photon excitation has been successfully applied in conventional FCS,((21,46)) its employment for DC-FCCS is expected to signif…”
BackgroundHidalgo, G., Burns, A., Herz, E., Hay, A. G., Houston, P. L., Wiesner, U., & Lion, L. W. (2009) · Applied and Environmental Microbiology · doi:10.1128/aem.01220-09 · Cited by 127
“Several recent reviews further elaborate on the relative merits of single and multiphoton imaging techniques (19, 57).”
BackgroundVisualization of Retinoid Storage and Trafficking by Two-Photon Microscopy
Imanishi, Y., & Palczewski, K. (2010) · Methods in Molecular Biology · doi:10.1007/978-1-60327-325-1_14 · Cited by 16
Metadata
- Authors
- Williams, R. M., Piston, D. W., & Webb, W. W.
- Venue
- The FASEB Journal
- Publisher
- Wiley
- Published
- 1994-08
- Volume
- 8
- Issue
- 11
- Pages
- 804-813
- ISSN
- 0892-6638 (ISSN-L)
- 1530-6860
- OpenAlex
- W2155757349
- Cited by
- 235
- References
- 2
- FWCI
- 9.04
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.