CoChat

Different Responses of Ear and Finger Pulse Oximeter Wave Form to Cold Pressor Test

Awad, Aymen A., Ghobashy, M. Ashraf M., Ouda, Wagih, Stout, Robert G., Silverman, David G., Shelley, Kirk H. · 2001 · Anesthesia & Analgesia
Cited by 127

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

The cold pressor test is often used to assess vasoconstrictive responses because it simulates the vasoconstrictive challenges commonly encountered in the clinical setting. With IRB approval, 12 healthy volunteers, aged 25--50 yr, underwent baseline plethysmographic monitoring on the finger and ear. The contralateral hand was immersed in ice water for 30 s to elicit a systemic vasoconstrictive response while the recordings were continued. The changes in plethysmographic amplitude for the first 30 s of ice water immersion (period of maximum response) of the finger and ear were compared. The data indicate a significant disparity between the finger and the ear signals in response to the cold stimulus. The average finger plethysmographic amplitude measurement decreased by 48% +/- 19%. In contrast, no significant change was seen in the ear plethysmographic amplitude measurement, which decreased by 2% +/- 10%. We conclude that the ear is relatively immune to the vasoconstrictive effects. These findings suggest that the comparison of the ear and finger pulse oximeter wave forms might be used as a real-time monitor of sympathetic tone and that the ear plethysmography may be a suitable monitor of the systemic circulation.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00000539-200106000-00026

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 127

Metadata

Authors
Awad, A. A., Ghobashy, M. A. M., Ouda, W., Stout, R. G., Silverman, D. G., & Shelley, K. H.
Venue
Anesthesia & Analgesia
Published
2001-06
Volume
92
Issue
6
Pages
1483-1486
ISSN
0003-2999 (ISSN-L)
OpenAlex
W2170481266
Cited by
127
References
3
FWCI
0.92
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Different Responses of Ear and Finger Pulse Oximeter Wave Form to Cold Pressor Test. https://app.cochat.ai/papers/10.1097/00000539-200106000-00026
The paper
Awad, A. A., Ghobashy, M. A. M., Ouda, W., Stout, R. G., Silverman, D. G., & Shelley, K. H. (2001). Different Responses of Ear and Finger Pulse Oximeter Wave Form to Cold Pressor Test. Anesthesia & Analgesia. https://doi.org/10.1097/00000539-200106000-00026

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.