CoChat

Evaluation of the Ohmeda 3700 Pulse Oximeter: Steady-state and Transient Response Characteristics

Open access
Kagle, David M., Alexander, Christian M., Berko, Robert S., Gluffre, Maureen, Gross, Jeffrey B. · 1987 · Anesthesiology
Cited by 109

The DOI matches its Crossref record.

Abstract

The authors determined the accuracy of the Ohmeda 3700 (version J) pulse oximeter in healthy volunteers rendered hypoxic (SaO2 from 60-98%) by breathing mixtures of O2 in N2. When equipped with an ear probe, the pulse oximeter reading (y) reliably predicted arterial saturation (x) under steady-state conditions (y = 1.05x - 4.66, r = 0.98) as well as when oxygen saturation was rapidly decreasing (y = 1.05x - 6.38, r = 0.96). Conversely, when equipped with a finger probe, the oximeter tended to significantly underestimate steady-state arterial saturation (y = 1.21x - 19.1, r = 0.98, P less than 0.001). In response to this information, the manufacturer modified the oximeter's software (version XJ1), resulting in improved agreement between oximeter readings and arterial values (y = 0.96x + 4.59, r = 0.99). Despite the close correlation between steady-state oximeter readings and arterial saturation, the 99% prediction limits for both the ear and finger probes (version XJ1) were +/- 8%. Finger probe readings did not reliably reflect radial arterial oxygenation during rapid desaturation (y = 0.55x + 45.2, r = 0.78). This may be related to the time required to "arterialize" the blood in the finger; during acute resaturation, we found that the ear- to finger-probe delay was 24.0 +/- 2.3 s (means +/- SE, P less than 0.001).

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00000542-198703000-00018

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 109

Metadata

Authors
Kagle, D. M., Alexander, C. M., Berko, R. S., Gluffre, M., & Gross, J. B.
Venue
Anesthesiology
Published
1987-03-01
Volume
66
Issue
3
Pages
376-380
ISSN
0003-3022 (ISSN-L)
OpenAlex
W2069535946
Cited by
109
References
0
FWCI
15.38
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Evaluation of the Ohmeda 3700 Pulse Oximeter: Steady-state and Transient Response Characteristics. https://app.cochat.ai/papers/10.1097/00000542-198703000-00018
The paper
Kagle, D. M., Alexander, C. M., Berko, R. S., Gluffre, M., & Gross, J. B. (1987). Evaluation of the Ohmeda 3700 Pulse Oximeter: Steady-state and Transient Response Characteristics. Anesthesiology. https://doi.org/10.1097/00000542-198703000-00018

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.