Cited by 98Non-Invasive Vital Sign MonitoringHemodynamic Monitoring and TherapyThermal Regulation in Medicine

The desaturation response time of finger pulse oximeters during mild hypothermia*

MacLeod, D. B., Cortinez, L. I., Keifer, J. C., Cameron, D., Wright, D. R., White, W. D., Moretti, E. W., Radulescu, L. R. +1 more·2005·Anaesthesia

Abstract

Summary: Pulse oximeters may delay displaying the correct oxygen saturation during the onset of hypoxia. We investigated the desaturation response times of pulse oximeter sensors (forehead, ear and finger) during vasoconstriction due to mild hypothermia and vasodilation caused by glyceryl trinitrate. Ten healthy male volunteers were given three hypoxic challenges of 3 min duration under differing experimental conditions. Mild hypothermia increased the mean response time of finger oximeters from 130 to 215 s. Glyceryl trinitrate partly offset this effect by reducing the response time from 215 to 187 s. In contrast, the response times of the forehead and ear oximeters were unaffected by mild hypothermia, but the difference between head and finger oximeters was highly significant (p < 0.0001). The results suggest that the head oximeters provide a better monitoring site for pulse oximeters during mild hypothermia.

Integrity signals

Registry

Crossref · 10.1111/j.1365-2044.2004.04033.x

Cites

12 of 12 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • For infants who experience hypothermia or low body temperatures, distal measurement locations like the hand and foot often face limited perfusion to protect vital organs.

    “In addition, for infants who experience hypothermia or low body temperatures, which is common for infants in the Ethiopian NICU, distal measurement locations like the hand and foot often face limited perfusion to protect vital organs8–11.”

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
MacLeod, D. B., Cortinez, L. I., Keifer, J. C., Cameron, D., Wright, D. R., White, W. D., Moretti, E. W., Radulescu, L. R., & Somma, J.
Affiliations
  • Duke University (US)
  • Edinburgh Royal Infirmary (GB)
  • Duke Medical Center (US)
Corresponding author
MacLeod, D. B.
Venue
Anaesthesia
Publisher
Wiley
Published
2004-12-13
Volume
60
Issue
1
Pages
65-71
ISSN
  • 0003-2409 (ISSN-L)
  • 1365-2044
OpenAlex
W2150257143
Cited by
98
References
12
Citations by year
2026: 3 · 2025: 9 · 2024: 7 · 2023: 3 · 2022: 3 · 2021: 4 · 2020: 2 · 2019: 3 · 2018: 2 · 2017: 9 · 2016: 4 · 2015: 4 · 2014: 5 · 2013: 8 · 2012: 5
FWCI
3.36
Type
journal article
Language
en
Open access
closed
Locations
  • Anaesthesia (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
  • Health Sciences › Medicine › Surgery › Hemodynamic Monitoring and Therapy
  • Health Sciences › Medicine › Critical Care and Intensive Care Medicine › Thermal Regulation in Medicine
Keywords
pulse oximetry, mild hypothermia, hypoxia, vasoconstriction, vasodilation, nitroglycerin, oxygen saturation monitoring
MeSH terms
Adult, Hypoxia, Anthropometry, Fingers, Nitroglycerin, Humans, Hypothermia, Male, Monitoring, Physiologic, Oximetry, Reaction Time, Vasoconstriction, Vasodilation, Vasodilator Agents

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review