Adverse Respiratory Events in Anesthesia: A Closed Claims Analysis
Open accessThe DOI matches its Crossref record.
Abstract
Adverse outcomes associated with respiratory events constitute the single largest class of injury in the American Society of Anesthesiology Closed Claims Study (522 of 1541 cases; 34%). Death or brain damage occurred in 85% of cases. The median cost of settlement or jury award was +200,000. Most outcomes (72%) were considered preventable with better monitoring. Three mechanisms of injury accounted for three-fourths of the adverse respiratory events: inadequate ventilation (196; 38%), esophageal intubation (94; 18%), and difficult tracheal intubation (87; 17%). Inadequate ventilation was used to describe claims in which it was evident that insufficient gas exchange had produced the adverse outcome, but it was not possible to identify the exact cause. This group was characterized by the highest proportion of cases in which care was considered substandard (90%). The esophageal intubation group was notable for a recurring diagnostic failure: in 48% of cases where auscultation of breath sounds was performed and documented, this test led to the erroneous conclusion that the endotracheal tube was correctly located in the trachea. Claims for difficult tracheal intubation were distinguished by a comparatively small proportion of cases (36%) in which the outcome was considered preventable with better monitoring. A better understanding of respiratory risks may require investigative protocols that initiate data collection immediately upon the recognition of a critical incident or adverse outcome.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Cook, T. M., Woodall, N., & Frerk, C. (2011) · British Journal of Anaesthesia · doi:10.1093/bja/aer058 · Cited by 2,415
Cook, T. M., Woodall, N., Harper, J., & Benger, J. (2011) · British Journal of Anaesthesia · doi:10.1093/bja/aer059 · Cited by 1,065
Difficult Airway Society guidelines for management of the unanticipated difficult intubation
Henderson, J. J., Popat, M. T., Latto, I. P., & Pearce, A. C. (2004) · Anaesthesia · doi:10.1111/j.1365-2044.2004.03831.x · Cited by 1,025
Emergency Tracheal Intubation: Complications Associated with Repeated Laryngoscopic Attempts
Mort, T. C. (2004) · Anesthesia & Analgesia · doi:10.1213/01.ane.0000122825.04923.15 · Cited by 995
Prediction of Difficult Mask Ventilation
Langeron, O., Masso, E., Huraux, C., Guggiari, M., Bianchi, A., Coriat, P., & Riou, B. (2000) · Anesthesiology · doi:10.1097/00000542-200005000-00009 · Cited by 915
Adnet, F., Borron, S. W., Racine, S. X., Clemessy, J.-L., Fournier, J.-L., Plaisance, P., & Lapandry, C. (1997) · Anesthesiology · doi:10.1097/00000542-199712000-00005 · Cited by 703
Jaber, S., Amraoui, J., Lefrant, J.-Y., Arich, C., Cohendy, R., Landreau, L., Calvet, Y., Capdevila, X., Mahamat, A., & Eledjam, J.-J. (2006) · Critical Care Medicine · doi:10.1097/01.ccm.0000233879.58720.87 · Cited by 675
The airway: problems and predictions in 18,500 patients
Rose, D. K., & Cohen, M. M. (1994) · Canadian Journal of Anaesthesia · doi:10.1007/bf03009858 · Cited by 645
The unanticipated difficult airway with recommendations for management
Crosby, E. T., Cooper, R. M., Douglas, M. J., Doyle, D. J., Hung, O. R., Labrecque, P., Muir, H., Murphy, M. F., Preston, R. P., Rose, D. K., et al. (1998) · Canadian Journal of Anaesthesia · doi:10.1007/bf03012147 · Cited by 615
Preoperative Airway Assessment: Predictive Value of a Multivariate Risk Index
El-Ganzouri, A. R., McCarthy, R. J., Tuman, K. J., Tanck, E. N., & Ivankovich, A. D. (1996) · Anesthesia & Analgesia · doi:10.1097/00000539-199606000-00017 · Cited by 553
Complications and failure of airway management
Cook, T. M., & MacDougall-Davis, S. R. (2012) · British Journal of Anaesthesia · doi:10.1093/bja/aes393 · Cited by 525
Effect of Outcome on Physician Judgments of Appropriateness of Care
Caplan, R. A. (1991) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1991.03460150061024 · Cited by 382
Self-citationVideolaryngoscopy versus direct laryngoscopy for adult patients requiring tracheal intubation
Lewis, S. R., Butler, A. R., Parker, J., Cook, T. M., & Smith, A. F. (2016) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd011136.pub2 · Cited by 374
Lewis, S. R., Butler, A. R., Parker, J., Cook, T. M., Schofield-Robinson, O. J., & Smith, A. F. (2017) · British Journal of Anaesthesia · doi:10.1093/bja/aex228 · Cited by 359
The Australian Incident Monitoring Study: An Analysis of 2000 Incident Reports
Webb, R. K., Currie, M., Morgan, C. A., Williamson, J. A., Mackay, P., Russell, W. J., & Runciman, W. B. (1993) · Anaesthesia and Intensive Care · doi:10.1177/0310057x9302100507 · Cited by 352
Cheney, F. W. (1999) · Anesthesiology · doi:10.1097/00000542-199908000-00030 · Cited by 329
Self-citationMetzner, J., Posner, K. L., Lam, M. S., & Domino, K. B. (2011) · Best Practice & Research Clinical Anaesthesiology · doi:10.1016/j.bpa.2011.02.007 · Cited by 325
Self-citationBrain, A. I., Verghese, C., Addy, E. V., Kapila, A., & Brimacombe, J. (1997) · British Journal of Anaesthesia · doi:10.1093/bja/79.6.704 · Cited by 323
Video‐laryngoscopes in the adult airway management: a topical review of the literature
NIFOROPOULOU, P., PANTAZOPOULOS, I., DEMESTIHA, T., KOUDOUNA, E., & XANTHOS, T. (2010) · Acta Anaesthesiologica Scandinavica · doi:10.1111/j.1399-6576.2010.02285.x · Cited by 316
Update on Bispectral Index monitoring
Johansen, J. W. (2006) · Best Practice & Research Clinical Anaesthesiology · doi:10.1016/j.bpa.2005.08.004 · Cited by 313
Use of the Intubating LMA-Fastrach™ in 254 Patients with Difficult-to-manage Airways
Ferson, D. Z., Rosenblatt, W. H., Johansen, M. J., Osborn, I., & Ovassapian, A. (2001) · Anesthesiology · doi:10.1097/00000542-200111000-00022 · Cited by 310
French Survey of Anesthesia in 1996
Clergue, F., Auroy, Y., Péquignot, F., Jougla, E., Lienhart, A., & Laxenaire, M.-C. (1999) · Anesthesiology · doi:10.1097/00000542-199911000-00045 · Cited by 303
Mortality associated with anaesthesia: a qualitative analysis to identify risk factors
Arbous, M. S., Grobbee, D. E., van Kleef, J. W., de Lange, J. J., Spoormans, H. H. A. J. M., Touw, P., Werner, F. M., & Meursing, A. E. E. (2001) · Anaesthesia · doi:10.1046/j.1365-2044.2001.02051.x · Cited by 294
Mort, T. C. (2004) · Journal of Clinical Anesthesia · doi:10.1016/j.jclinane.2004.01.007 · Cited by 276
Will This Patient Be Difficult to Intubate?: The Rational Clinical Examination Systematic Review
Detsky, M. E., Jivraj, N., Adhikari, N. K., Friedrich, J. O., Pinto, R., Simel, D. L., Wijeysundera, D. N., & Scales, D. C. (2019) · JAMA · doi:10.1001/jama.2018.21413 · Cited by 265
Gali, B., Whalen, F. X., Schroeder, D. R., Gay, P. C., & Plevak, D. J. (2009) · Anesthesiology · doi:10.1097/aln.0b013e31819b5d70 · Cited by 264
Citation Classics in Anesthetic Journals
Baltussen, A., & Kindler, C. H. (2004) · Anesthesia & Analgesia · doi:10.1213/01.ane.0000096185.13474.0a · Cited by 261
Romero, L. M., & Remage-Healey, L. (2000) · General and Comparative Endocrinology · doi:10.1006/gcen.2000.7491 · Cited by 259
Rosenstock, C. V., Thøgersen, B., Afshari, A., Christensen, A.-L., Eriksen, C., & Gätke, M. R. (2012) · Anesthesiology · doi:10.1097/aln.0b013e318254d085 · Cited by 255
Pulse oximetry for perioperative monitoring
Pedersen, T., Nicholson, A., Hovhannisyan, K., Møller, A. M., Smith, A. F., & Lewis, S. R. (2014) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd002013.pub3 · Cited by 249
Complications associated with the use of the GlideScope® videolaryngoscope
Cooper, R. M. (2007) · Canadian Journal of Anesthesia/Journal canadien d'anesthésie · doi:10.1007/bf03021900 · Cited by 238
Difficult laryngoscopy made easy with a “BURP”
Knill, R. L. (1993) · Canadian Journal of Anaesthesia · doi:10.1007/bf03037041 · Cited by 237
“My hypothesis was that in some cases of difficult laryngoscopy, the view of the glottis could be improved by manually displacing the larynx in three specific directions - i.e., (I) posteriorly against the cervical vertebrae, (2) superiorly as far as possible and ( 3 ) slightly laterally to the right.”
BackgroundSilvestri, S., Ralls, G. A., Krauss, B., Thundiyil, J., Rothrock, S. G., Senn, A., Carter, E., & Falk, J. (2005) · Annals of Emergency Medicine · doi:10.1016/j.annemergmed.2004.09.014 · Cited by 230
Malik, M. A., Maharaj, C. H., Harte, B. H., & Laffey, J. G. (2008) · British Journal of Anaesthesia · doi:10.1093/bja/aen231 · Cited by 229
Effect of Nitrous Oxide on Excitatory and Inhibitory Synaptic Transmission in Hippocampal Cultures
Mennerick, S., Jevtovic-Todorovic, V., Todorovic, S. M., Shen, W., Olney, J. W., & Zorumski, C. F. (1998) · The Journal of Neuroscience · doi:10.1523/jneurosci.18-23-09716.1998 · Cited by 224
The intubating laryngeal maskResults of a multicentre trial with experience of 500 cases
Baskett, P. J. F., Parr, M. J. A., & Nolan, J. P. (1998) · Anaesthesia · doi:10.1046/j.1365-2044.1998.00614.x · Cited by 224
Li, J. (2001) · The Journal of Emergency Medicine · doi:10.1016/s0736-4679(00)00318-8 · Cited by 222
Brodbelt, D. C., Pfeiffer, D. U., Young, L. E., & Wood, J. L. N. (2007) · British Journal of Anaesthesia · doi:10.1093/bja/aem229 · Cited by 222
Brimacombe, J. R., & Berry, A. M. (1997) · Canadian Journal of Anaesthesia · doi:10.1007/bf03014464 · Cited by 213
Adnet, F., Jouriles, N. J., Le Toumelin, P., Hennequin, B., Taillandier, C., Rayeh, F., Couvreur, J., Nougière, B., Nadiras, P., Ladka, A., et al. (1998) · Annals of Emergency Medicine · doi:10.1016/s0196-0644(98)70175-1 · Cited by 194
An Evaluation of a Virtual Reality Airway Simulator
Rowe, R., & Cohen, R. A. (2002) · Anesthesia & Analgesia · doi:10.1097/00000539-200207000-00011 · Cited by 192
“In the list of reasons for anesthesia-related injuries in the United States, adverse respiratory events cause the most harm (18).”
BackgroundMaharaj, C. H., Buckley, E., Harte, B. H., & Laffey, J. G. (2007) · Anesthesiology · doi:10.1097/01.anes.0000267529.71756.f0 · Cited by 192
Predicting difficult intubation: a multivariable analysis
Karkouti, K., Rose, D. K., Wigglesworth, D., & Cohen, M. M. (2000) · Canadian Journal of Anesthesia/Journal canadien d'anesthésie · doi:10.1007/bf03019474 · Cited by 192
Munnur, U., de Boisblanc, B., & Suresh, M. S. (2005) · Critical Care Medicine · doi:10.1097/01.ccm.0000183502.45419.c9 · Cited by 185
Heard, A. M. B., Green, R. J., & Eakins, P. (2009) · Anaesthesia · doi:10.1111/j.1365-2044.2009.05888.x · Cited by 182
Mihai, R., Blair, E., Kay, H., & Cook, T. M. (2008) · Anaesthesia · doi:10.1111/j.1365-2044.2008.05489.x · Cited by 179
Green, S. M., & Krauss, B. (2002) · Academic Emergency Medicine · doi:10.1111/j.1553-2712.2002.tb01164.x · Cited by 177
Larsen, B., Seitz, A., & Larsen, R. (2000) · Anesthesia & Analgesia · doi:10.1097/00000539-200001000-00035 · Cited by 173
Strategies for the prevention of airway complications – a narrative review
Cook, T. M. (2018) · Anaesthesia · doi:10.1111/anae.14123 · Cited by 167
“• The ASA Closed Claims Project has also provided considerable insight into the more severe airway misadventures over a period of two decades [31, 32].”
BackgroundFatal and non fatal cardiac arrests related to anesthesia
Biboulet, P., Aubas, P., Dubourdieu, J., Rubenovitch, J., Capdevila, X., & d’Athis, F. (2001) · Canadian Journal of Anesthesia/Journal canadien d'anesthésie · doi:10.1007/bf03014958 · Cited by 163
Malik, M. A., Subramaniam, R., Maharaj, C. H., Harte, B. H., & Laffey, J. G. (2009) · British Journal of Anaesthesia · doi:10.1093/bja/aep266 · Cited by 163
Woodall, N. M., & Cook, T. M. (2011) · British Journal of Anaesthesia · doi:10.1093/bja/aeq339 · Cited by 161
Risk Factors Assessment of the Difficult Airway: An Italian Survey of 1956 Patients
Cattano, D., Panicucci, E., Paolicchi, A., Forfori, F., Giunta, F., & Hagberg, C. (2004) · Anesthesia & Analgesia · doi:10.1213/01.ane.0000136772.38754.01 · Cited by 159
Metadata
- Authors
- Caplan, R. A., Posner, K. L., Ward, R. J., & Cheney, F. W.
- Venue
- Anesthesiology
- Published
- 1990-05-01
- Volume
- 72
- Issue
- 5
- Pages
- 828-833
- ISSN
- 0003-3022 (ISSN-L)
- OpenAlex
- W1996859235
- Cited by
- 1,060
- References
- 0
- FWCI
- 39.94
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.