Inspiratory Pressure Support Compensates for the Additional Work of Breathing Caused by the Endotracheal Tube
Open accessThe DOI matches its Crossref record.
Abstract
Breathing through an endotracheal tube and a demand valve may increase the work performed by the respiratory muscles. Inspiratory pressure support (PS) is known to reduce this work and might therefore compensate for this increased requirement. To test this hypothesis, we measured the work of breathing (WOB) in 11 patients whose tracheas were intubated. Five had no intrinsic lung disease, but six had chronic obstructive lung disease. We compared WOB measurements taken under several sets of conditions: during assisted breathing at four levels of PS, during unassisted breathing and connection to a T-piece, and after extubation of the trachea. During unassisted breathing via the ventilator circuit (PS set at 0 cmH20), the WOB per minute was greater than that after extubation, with a mean increase (+/- standard deviation) of 68 +/- 38% (10.3 +/- 5.1 vs. 6.5 +/- 3.7 J.min-1, P less than 0.01). While breathing through the T-piece, the WOB was 27 +/- 18% greater than after tracheal extubation (8.2 +/- 5.1 vs. 6.5 +/- 3.7 J.min-1, P less than 0.05). The principal reason why inspiratory work decreased after extubation was that the ventilatory requirement decreased. For each patient, we determined retrospectively, after extubation, the level of PS that had reduced WOB to its postextubation value and obtained levels ranging from 3.4 to 14.4 cmH2O. The PS level at which additional WOB was compensated for, was greater in patients with chronic lung disease than in those free of lung disease (12.0 +/- 1.9 vs. 5.7 +/- 1.5 cm H2O, P less than 0.05).(ABSTRACT TRUNCATED AT 250 WORDS)
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
A Comparison of Four Methods of Weaning Patients from Mechanical Ventilation
Esteban, A., Frutos, F., Tobin, M. J., Alía, I., Solsona, J. F., Valverdu, V., Fernández, R., de la Cal, M. A., Benito, S., Tomás, R., et al. (1995) · New England Journal of Medicine · doi:10.1056/nejm199502093320601 · Cited by 1,549
Brochard, L., Rauss, A., Benito, S., Conti, G., Mancebo, J., Rekik, N., Gasparetto, A., & Lemaire, F. (1994) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.150.4.7921460 · Cited by 1,122
Self-citationExtubation Outcome after Spontaneous Breathing Trials with T-Tube or Pressure Support Ventilation
ESTEBAN, A., ALÍA, I., GORDO, F., FERNÁNDEZ, R., SOLSONA, J. F., VALLVERDÚ, I., MACÍAS, S., ALLEGUE, J. M., BLANCO, J., CARRIEDO, D., et al. (1997) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.156.2.9610109 · Cited by 795
Neural control of mechanical ventilation in respiratory failure
Sinderby, C., Navalesi, P., Beck, J., Skrobik, Y., Comtois, N., Friberg, S., Gottfried, S. B., & Lindström, L. (1999) · Nature Medicine · doi:10.1038/71012 · Cited by 636
The Decision to Extubate in the Intensive Care Unit
Thille, A. W., Richard, J.-C. M., & Brochard, L. (2013) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201208-1523ci · Cited by 576
Self-citationSlutsky, A. S. (1993) · Chest · doi:10.1378/chest.104.6.1833 · Cited by 563
Advances in Mechanical Ventilation
Tobin, M. J. (2001) · New England Journal of Medicine · doi:10.1056/nejm200106283442606 · Cited by 475
A Multicenter Randomized Trial of Computer-driven Protocolized Weaning from Mechanical Ventilation
Lellouche, F., Mancebo, J., Jolliet, P., Roeseler, J., Schortgen, F., Dojat, M., Cabello, B., Bouadma, L., Rodriguez, P., Maggiore, S., et al. (2006) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200511-1780oc · Cited by 406
Self-citationRandolph, A. G. (2002) · JAMA · doi:10.1001/jama.288.20.2561 · Cited by 401
GIRAULT, C., DAUDENTHUN, I., CHEVRON, V., TAMION, F., LEROY, J., & BONMARCHAND, G. (1999) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.160.1.9802120 · Cited by 365
Epstein, S. (2002) · Intensive Care Medicine · doi:10.1007/s00134-002-1268-8 · Cited by 288
Nava, S., Ferrer, M., Esquinas, A., Scala, R., Groff, P., Cosentini, R., Guido, D., Lin, C.-H., Cuomo, A. M., & Grassi, M. (2013) · The Lancet Oncology · doi:10.1016/s1470-2045(13)70009-3 · Cited by 273
Respiratory management of inhalation injury
Mlcak, R. P., Suman, O. E., & Herndon, D. N. (2007) · Burns · doi:10.1016/j.burns.2006.07.007 · Cited by 252
Etiology of extubation failure and the predictive value of the rapid shallow breathing index.
Epstein, S. K. (1995) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.152.2.7633705 · Cited by 252
Changes in Respiratory Mechanics After Tracheostomy
Davis, K. (1999) · Archives of Surgery · doi:10.1001/archsurg.134.1.59 · Cited by 170
“The imposed WOB caused by the presence of an endotracheal tube has been studied by numerous investigators.(8-12) Decreasing the diameter of the tube and increasing flow (patient demand) through the tube increase the imposed work.”
BackgroundAcute effects of inspiratory pressure support during exercise in patients with COPD
van 't Hul, A., Gosselink, R., Hollander, P., Postmus, P., & Kwakkel, G. (2004) · European Respiratory Journal · doi:10.1183/09031936.03.00016903 · Cited by 79
Metadata
- Authors
- Brochard, L., Rua, F., Lorino, H., Lemaire, F., & Harf, A.
- Venue
- Anesthesiology
- Published
- 1991-11-01
- Volume
- 75
- Issue
- 5
- Pages
- 739-745
- ISSN
- 0003-3022 (ISSN-L)
- OpenAlex
- W2094923585
- Cited by
- 348
- References
- 0
- FWCI
- 7.76
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.