Heat Flow and Distribution during Epidural Anesthesia
The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
Abstract
Background: Core hypothermia after induction of epidural anesthesia results from both an internal core-to-peripheral redistribution of body heat and a net loss of heat to the environment. However, the relative contributions of each mechanism remain unknown. The authors thus evaluated regional body heat content and the extent to which core hypothermia after induction of anesthesia resulted from altered heat balance and internal heat redistribution.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The measurement of volume changes in human limbs
Whitney, R. J. (1953) · The Journal of Physiology · doi:10.1113/jphysiol.1953.sp004926 · Cited by 1,489
LASER DOPPLER MEASUREMENT OF CUTANEOUS BLOOD FLOW
Holloway, G. A., & Watkins, D. W. (1977) · Journal of Investigative Dermatology · doi:10.1111/1523-1747.ep12507665 · Cited by 538
Heat Flow and Distribution during Induction of General Anesthesia
Matsukawa, T., Sessler, D. I., Sessler, A. M., Schroeder, M., Ozaki, M., Kurz, A., & Cheng, C. (1995) · Anesthesiology · doi:10.1097/00000542-199503000-00008 · Cited by 528
Self-citationSkin-surface Temperature Gradients Correlate with Fingertip Blood Flow in Humans
Rubinstein, E. H., & Sessler, D. I. (1990) · Anesthesiology · doi:10.1097/00000542-199009000-00027 · Cited by 388
Self-citationTRANSEPIDERMAL WATER LOSS IN NEWBORN INFANTS: III. Relation to Gestational Age
HAMMARLUND, K., & SEDIN, G. (2008) · Acta Paediatrica · doi:10.1111/j.1651-2227.1979.tb08214.x · Cited by 315
A new approach for the estimation of body composition: infrared interactance
Conway, J., Norris, K., & Bodwell, C. (1984) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/40.6.1123 · Cited by 311
Determination of esophageal probe insertion length based on standing and sitting height
Mekjavic, I. B., & Rempel, M. E. (1990) · Journal of Applied Physiology · doi:10.1152/jappl.1990.69.1.376 · Cited by 249
Physiologic Responses to Mild Perianesthetic Hypothermia in Humans
Sessler, D. I., Rubinstein, E. H., & Moayeri, A. (1991) · Anesthesiology · doi:10.1097/00000542-199110000-00009 · Cited by 248
Self-citationThermoregulatory Thresholds during Epidural and Spinal Anesthesia
Ozaki, M., Kurz, A., Sessler, D. I., Lenhardt, R., Schroeder, M., Moayeri, A., Noyes, K. M., & Rotheneder, E. (1994) · Anesthesiology · doi:10.1097/00000542-199408000-00004 · Cited by 202
Self-citationSkin-Surface Warming: Heat Flux and Central Temperature
Sessler, D. I., & Moayeri, A. (1990) · Anesthesiology · doi:10.1097/00000542-199008000-00005 · Cited by 199
Self-citationA New Method for Monitoring Deep Body Temperature from the Skin Surface
Fox, R. H., Solman, A. J., Isaacs, R., Fry, A. J., & MacDonald, I. C. (1973) · Clinical Science · doi:10.1042/cs0440081 · Cited by 168
Circulatory Effects of Peridural Block: I. Effects of Level of Analgesia and Dose of Lidocaine
Bonica, J. J., Berges, P. U., & Morikawa, K. (1970) · Anesthesiology · doi:10.1097/00000542-197012000-00008 · Cited by 151
Kurz, A. M., Plattner, O., Sessler, D. I., Huemer, G., REDL, G., & Lackner, F. X. (1993) · Anesthesiology · doi:10.1097/00000542-199309000-00008 · Cited by 145
Self-citationShivering following cardiac surgery: Hemodynamic changes and reversal
Guffin, A. V., Girard, D. C., & Kaplan, J. A. (1987) · Journal of Cardiothoracic Anesthesia · doi:10.1016/s0888-6296(87)92593-2 · Cited by 135
Heat Loss in Humans Covered with Cotton Hospital Blankets
Sessler, D. I., & Schroeder, M. (1993) · Anesthesia & Analgesia · doi:10.1213/00000539-199307000-00014 · Cited by 127
Self-citationNaloxone, Meperidine, and Shivering
Kurz, M., Belani, K. G., Sessler, D. I., Kurz, A. M., Larson, M. D., Schroeder, M., & Blanchard, D. (1993) · Anesthesiology · doi:10.1097/00000542-199312000-00009 · Cited by 123
Self-citationMidazolam Minimally Impairs Thermoregulatory Control
Kurz, A., Sessler, D. I., Annadata, R., Dechert, M., Christensen, R., & Bjorksten, A. R. (1995) · Anesthesia & Analgesia · doi:10.1097/00000539-199508000-00032 · Cited by 116
Self-citationThe Thermoregulatory Threshold in Humans during Nitrous Oxide-Fentanyl Anesthesia
Sessler, D. I., Olofsson, C. I., & Rubinstein, E. H. (1988) · Anesthesiology · doi:10.1097/00000542-198809000-00012 · Cited by 113
Self-citationEpidural Anesthesia Increases Apparent Leg Temperature and Decreases the Shivering Threshold
Emerick, T., Ozaki, M., Sessler, D. I., Walters, K., & Schroeder, M. (1994) · Anesthesiology · doi:10.1097/00000542-199408000-00005 · Cited by 98
Self-citationThermal Balance and Tremor Patterns during Epidural Anesthesia
Hynson, J. M., Sessler, D. I., Glosten, B., & McGuire, J. (1991) · Anesthesiology · doi:10.1097/00000542-199104000-00011 · Cited by 89
Self-citationShimosato, S., & Etsten, B. E. (1969) · Anesthesiology · doi:10.1097/00000542-196906000-00009 · Cited by 82
A modified internal temperature measurement device
Togwa, T., Nemoto, T., Yamazaki, T., & Kobayashi, T. (1976) · Medical & Biological Engineering & Computing · doi:10.1007/bf02478138 · Cited by 80
Leslie, K., Sessler, D. I., Bjorksten, A. R., Ozaki, M., Matsukawa, T., Schroeder, M., & Lin, S. (1994) · Anesthesiology · doi:10.1097/00000542-199408000-00013 · Cited by 75
Self-citationThe Shivering Threshold during Spinal Anesthesia Is Reduced in the Elderly
Vassilieff, N., Rosencher, N., Sessler, D., & Conseiller, C. (1994) · Anesthesiology · doi:10.1097/00000542-199409001-00012 · Cited by 37
Self-citationIntravenous Lidocaine Does Not Cause Shivering-like Tremor or Alter Thermoregulation
Glosten, B., Faure, E. A. M., Sessler, D. I., Karl, L., Östman, L. G., & Thisted, R. A. (1991) · Regional Anesthesia The Journal of Neural Blockade in Obstetrics Surgery & Pain Control · doi:10.1136/rapm-00115550-199116040-00007 · Cited by 19
Self-citation
Cited by
The Effects of Mild Perioperative Hypothermia on Blood Loss and Transfusion Requirement
Rajagopalan, S., Mascha, E., Na, J., & Sessler, D. I. (2008) · Anesthesiology · doi:10.1097/01.anes.0000296719.73450.52 · Cited by 905
Self-citationTemperature Monitoring and Perioperative Thermoregulation
Sessler, D. I., Warner, D. S., & Warner, M. A. (2008) · Anesthesiology · doi:10.1097/aln.0b013e31817f6d76 · Cited by 758
Self-citationMild Perioperative Hypothermia
Sessler, D. I. (1997) · New England Journal of Medicine · doi:10.1056/nejm199706123362407 · Cited by 659
Self-citationPerioperative thermoregulation and heat balance
Sessler, D. I. (2016) · The Lancet · doi:10.1016/s0140-6736(15)00981-2 · Cited by 593
Self-citationSessler, D. I., & Todd, M. M. (2000) · Anesthesiology · doi:10.1097/00000542-200002000-00042 · Cited by 557
Self-citation
Metadata
- Authors
- Matsukawa, T., Sessler, D. I., Christensen, R., Ozaki, M., & Schroeder, M.
- Venue
- Anesthesiology
- Published
- 1995-11-01
- Volume
- 83
- Issue
- 5
- Pages
- 961-967
- ISSN
- 0003-3022 (ISSN-L)
- OpenAlex
- W2075326501
- Cited by
- 290
- References
- 25
- FWCI
- 12.49
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.