Approximate Entropy as an Electroencephalographic Measure of Anesthetic Drug Effect during Desflurane Anesthesia
The DOI matches its Crossref record.
Abstract
Background: The authors hypothesized that the electroencephalogram (EEG) during higher anesthetic concentrations would show more "order" and less "randomness" than at lower anesthetic concentrations. "Approximate entropy" is a new statistical parameter derived from the Kolmogorov-Sinai entropy formula which quantifies the amount of regularity in data. The approximate entropy quantifies the predictability of subsequent amplitude values of the EEG based on the knowledge of the previous amplitude values. The authors investigated the dose-response relation of the EEG approximate entropy during desflurane anesthesia in comparison with spectral edge frequency 95, median frequency, and bispectral index. Methods: Twelve female patients were studied during gynecologic laparotomies. Between opening and closure of the peritoneum, end-tidal desflurane concentrations were varied between 0.5 and 1.6 minimum alveolar concentration (MAC). The EEG approximate entropy, median EEG frequency, spectral edge frequency 95, and bispectral index were determined and the performance of each to predict the desflurane effect compartment concentration, obtained by simultaneous pharmacokinetic-pharmacodynamic modeling, was compared. Results: Electroencephalogram approximate entropy decreased continuously over the observed concentration range of desflurane. The performance of the approximate entropy (prediction probability PK = 0.86 +/- 0.06) as an indicator for desflurane concentrations is similar to spectral edge frequency 95 (PK = 0.86 +/- 0.06) and bispectral index (PK = 0.82 +/- 0.06) and is statistically significantly better than median frequency (PK = 0.78 +/- 0.06). Conclusions: The amount of regularity in the EEG increases with increasing desflurane concentrations. The approximate entropy could be a useful EEG measure of anesthetic drug effect.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Characterization of Surface EMG Signal Based on Fuzzy Entropy
Chen, W., Wang, Z., Xie, H., & Yu, W. (2007) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2007.897025 · Cited by 1,094
Measuring complexity using FuzzyEn, ApEn, and SampEn
Chen, W., Zhuang, J., Yu, W., & Wang, Z. (2009) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2008.04.005 · Cited by 723
Subha, D. P., Joseph, P. K., Acharya U, R., & Lim, C. M. (2010) · Journal of Medical Systems · doi:10.1007/s10916-008-9231-z · Cited by 627
Approximate Entropy-Based Epileptic EEG Detection Using Artificial Neural Networks
Srinivasan, V., Eswaran, C., & Sriraam, N. (2007) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2006.884369 · Cited by 591
Description of the Entropy™ algorithm as applied in the Datex‐Ohmeda S/5™ Entropy Module
Viertiö‐Oja, H., Maja, V., Särkelä, M., Talja, P., Tenkanen, N., Tolvanen‐Laakso, H., Paloheimo, M., Vakkuri, A., Yli‐Hankala, A., & Meriläinen, P. (2004) · Acta Anaesthesiologica Scandinavica · doi:10.1111/j.0001-5172.2004.00322.x · Cited by 582
EEG complexity as a measure of depth of anesthesia for patients
Zhang, X.-S., Roy, R. J., & Jensen, E. W. (2001) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.966601 · Cited by 495
Complex systems and the technology of variability analysis
Seely, A. J., & Macklem, P. T. (2004) · Critical Care · doi:10.1186/cc2948 · Cited by 447
Assessing Serial Irregularity and Its Implications for Health
PINCUS, S. M. (2001) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.2001.tb02755.x · Cited by 401
Bouillon, T. W., Bruhn, J., Radulescu, L., Andresen, C., Shafer, T. J., Cohane, C., & Shafer, S. L. (2004) · Anesthesiology · doi:10.1097/00000542-200406000-00006 · Cited by 375
Self-citationDepth of anaesthesia monitoring: what’s available, what’s validated and what’s next?
Bruhn, J., Myles, P. S., Sneyd, R., & Struys, M. M. R. F. (2006) · British Journal of Anaesthesia · doi:10.1093/bja/ael120 · Cited by 341
Self-citationEEG entropy measures in anesthesia
Liang, Z., Wang, Y., Sun, X., Li, D., Voss, L. J., Sleigh, J. W., Hagihira, S., & Li, X. (2015) · Frontiers in Computational Neuroscience · doi:10.3389/fncom.2015.00016 · Cited by 306
Advances in Quantitative Electroencephalogram Analysis Methods
Thakor, N. V., & Tong, S. (2004) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.5.040202.121601 · Cited by 305
Vakkuri, A., Yli‐Hankala, A., Talja, P., Mustola, S., Tolvanen‐Laakso, H., Sampson, T., & Viertiö‐Oja, H. (2004) · Acta Anaesthesiologica Scandinavica · doi:10.1111/j.0001-5172.2004.00323.x · Cited by 293
Nonlinear analysis of EEG signals at different mental states
Natarajan, K., Acharya U, R., Alias, F., Tiboleng, T., & Puthusserypady, S. K. (2004) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-3-7 · Cited by 292
Schartner, M., Seth, A., Noirhomme, Q., Boly, M., Bruno, M.-A., Laureys, S., & Barrett, A. (2015) · PLOS ONE · doi:10.1371/journal.pone.0133532 · Cited by 287
Sabeti, M., Katebi, S., & Boostani, R. (2009) · Artificial Intelligence in Medicine · doi:10.1016/j.artmed.2009.03.003 · Cited by 285
Hans, P., Dewandre, P.-Y., Brichant, J. F., & Bonhomme, V. (2005) · British Journal of Anaesthesia · doi:10.1093/bja/aei047 · Cited by 271
Comparison of Entropy and Complexity Measures for the Assessment of Depth of Sedation
Ferenets, R., Lipping, T., Anier, A., Jantti, V., Melto, S., & Hovilehto, S. (2006) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.873543 · Cited by 262
The Anesthetic Cascade: A Theory of How Anesthesia Suppresses Consciousness
John, E. R., & Prichep, L. S. (2005) · Anesthesiology · doi:10.1097/00000542-200502000-00030 · Cited by 250
“The S/5 Entropy Module (Datex-Ohmeda, Helsinki, Finland) computes the approximate entropy of the power spectrum to quantify the depth of anesthesia.(54,55) This method treats the quantitative electroencephalographic power spectrum obtained before induction of anesthesia essentially as the “ground state” of the organiz…”
MethodStruys, M. M. R. F., Jensen, E. W., Smith, W., Smith, N. T., Rampil, I., Dumortier, F. J. E., Mestach, C., & Mortier, E. P. (2002) · Anesthesiology · doi:10.1097/00000542-200204000-00006 · Cited by 223
“have a high sensitivity and specificity compared with other processed electroencephalograpic variables.(2,3) For MLAEP, Mantzaridis and Kenny(4) extracted a single nu-”
ResultUsing Permutation Entropy to Measure the Electroencephalographic Effects of Sevoflurane
Li, X., Cui, S., & Voss, L. J. (2008) · Anesthesiology · doi:10.1097/aln.0b013e318182a91b · Cited by 203
“Because AE specifies a noise threshold, it may be better than spectral entropy in the quantification of complexity of electroencephalographic recordings.(14,37) The disadvantage of AE is that it is heavily dependent on the record length and is often lower than expected for short records.”
BackgroundOptimal classification of epileptic seizures in EEG using wavelet analysis and genetic algorithm
Ocak, H. (2008) · Signal Processing · doi:10.1016/j.sigpro.2008.01.026 · Cited by 179
“ApEn is a measure of the predictability or the regularity of a time series that have been applied to EEG in the literature for sleep analysis [16], identification of the burst suppression patterns [17] and anesthetic depth monitoring [18].”
BackgroundVanluchene, A. L. G., Vereecke, H., Thas, O., Mortier, E. P., Shafer, S. L., & Struys, M. M. R. F. (2004) · Anesthesiology · doi:10.1097/00000542-200407000-00008 · Cited by 178
“That is, given two randomly selected electroencephalographic-derived data points with distinct anesthetic drug concentration, PK is the probability that the indicator describes correctly which of the data points is the one with the higher (or lower) anesthetic drug concentration.(2) To avoid an overwhelming influFig.”
BackgroundBettinardi, R. G., Tort-Colet, N., Ruiz-Mejias, M., Sanchez-Vives, M. V., & Deco, G. (2015) · NeuroImage · doi:10.1016/j.neuroimage.2015.03.037 · Cited by 68
“We believe that taken together, our findings could indicate that one of the global effects of anesthesia is that of reducing the overall dynamical complexity, as also suggested by findings indicating a decrease in EEG signal complexity in deep anesthesia (Bruhn et al., 2000; Zhang et al., 2001; Ferenets et al., 2007).”
BackgroundWong, W., Noreika, V., Móró, L., Revonsuo, A., Windt, J., Valli, K., & Tsuchiya, N. (2020) · Neuroscience of Consciousness · doi:10.1093/nc/niaa006 · Cited by 40
“2019), higher signal entropy or complexity (Bruhn et al. 2000; Bein 2006; King et al. 2013; Liang et al. 2013; Ouyang et al. 2013; Liang et al. 2015; Sarasso et al. 2015; Schartner et al. 2015; Hudetz et al. 2016; D’Andola et al. 2017), stronger phase coherence between brain areas (Nieminen et al.”
Background
Metadata
- Authors
- Bruhn, J., Röpcke, H., & Hoeft, A.
- Venue
- Anesthesiology
- Published
- 2000-03-01
- Volume
- 92
- Issue
- 3
- Pages
- 715-726
- ISSN
- 0003-3022 (ISSN-L)
- OpenAlex
- W2118694939
- Cited by
- 368
- References
- 0
- FWCI
- 10.93
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.