Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 240

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Effects of Mechanical Ventilation on Release of Cytokines into Systemic Circulation in Patients with Normal Pulmonary Function

Open access
Wrigge, Hermann, Zinserling, Jörg, Stüber, Frank, von Spiegel, Tilman, Hering, Rudolf, Wetegrove, Silke, Hoeft, Andreas, Putensen, Christian · 2000 · Anesthesiology

Abstract

Background: Mechanical ventilation with high tidal volumes (V(T)) in contrast to mechanical ventilation with low V(T) has been shown to increase plasma levels of proinflammatory and antiinflammatory mediators in patients with acute lung injury. The authors hypothesized that, in patients without previous lung injury, a conventional potentially injurious ventilatory strategy with high V(T) and zero end-expiratory pressure (ZEEP) will not cause a cytokine release into systemic circulation. Methods: A total of 39 patients with American Society of Anesthesiologists physical status I-II and without signs of systemic infection scheduled for elective surgery with general anesthesia were randomized to receive mechanical ventilation with either (1) V(T) = 15 ml/kg ideal body weight on ZEEP, (2) V(T) = 6 ml/kg ideal body weight on ZEEP, or (3) V(T) = 6 ml/kg ideal body weight on positive end-expiratory pressure of 10 cm H2O. Plasma levels of proinflammatory and antiinflammatory mediators tumor necrosis factor, interleukin (IL)-6, IL-10, and IL-1 receptor antagonist were determined before and 1 h after the initiation of mechanical ventilation. Results: Plasma levels of all cytokines remained low in all settings. IL-6, tumor necrosis factor, and IL-1 receptor antagonist did not change significantly after 1 h of mechanical ventilation. IL-10 was below the detection limit (10 pg/ml) in 35 of 39 patients. There were no differences between groups. Conclusions: Initiation of mechanical ventilation for 1 h in patients without previous lung injury caused no consistent changes in plasma levels of studied mediators. Mechanical ventilation with high V(T) on ZEEP did not result in higher cytokine levels compared with lung-protective ventilatory strategies. Previous lunge damage seems to be mandatory to cause an increase in plasma cytokines after 1 h of high V(T) mechanical ventilation.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00000542-200012000-00012

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 240

Metadata

Authors
Wrigge, H., Zinserling, J., Stüber, F., von Spiegel, T., Hering, R., Wetegrove, S., Hoeft, A., & Putensen, C.
Venue
Anesthesiology
Published
2000-12-01
Volume
93
Issue
6
Pages
1413-1417
ISSN
0003-3022 (ISSN-L)
OpenAlex
W2062246500
Cited by
240
References
4
FWCI
7.73
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Effects of Mechanical Ventilation on Release of Cytokines into Systemic Circulation in Patients with Normal Pulmonary Function. https://app.cochat.ai/papers/10.1097/00000542-200012000-00012
The paper
Wrigge, H., Zinserling, J., Stüber, F., von Spiegel, T., Hering, R., Wetegrove, S., Hoeft, A., & Putensen, C. (2000). Effects of Mechanical Ventilation on Release of Cytokines into Systemic Circulation in Patients with Normal Pulmonary Function. Anesthesiology. https://doi.org/10.1097/00000542-200012000-00012

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.