Use of Injectable Calcium Phosphate Cement for Fracture Fixation: A Review
The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Abstract
Injectable osteoconductive calcium phosphate cements have been introduced as an adjunct to internal fixation for treating selected fractures. These cements harden without producing much heat, develop compressive strength, and are remodeled slowly in vivo. The main purpose of the cement is to fill voids in metaphyseal bone, thereby reducing the need for bone graft, but cements also may improve the holding strength around metal devices in osteoporotic bone. Several bioactive cements are being developed. One of these cements, Skeletal Repair System, is available in Europe and has been approved by the United States Food and Drug Administration for use in selected distal radius fractures. Cadaveric studies have shown that using Skeletal Repair System cement with conventional metal fixation in certain fractures of the distal radius, tibial plateau, proximal femur, and calcaneus can produce better stability, stiffness, and strength than metal fixation alone. Early clinical results have shown reduced time to full weightbearing when cement has been used for augmentation of tibial plateau and calcaneal fractures, more rapid gain of strength and range of motion when used in distal radius fractures, and improved stability in certain hip fractures. Bioactive cements in general also may prove useful in vertebroplasty.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Skeletal Repair by in Situ Formation of the Mineral Phase of Bone
Constantz, B. R., Ison, I. C., Fulmer, M. T., Poser, R. D., Smith, S. T., VanWagoner, M., Ross, J., Goldstein, S. A., Jupiter, J. B., & Rosenthal, D. I. (1995) · Science · doi:10.1126/science.7892603 · Cited by 728
Roentgen stereophotogrammetry. A method for the study of the kinematics of the skeletal system.
Selvik, G. (1989) · PubMed · Cited by 702
Lu-Yao, G. L., Keller, R. B., Littenberg, B., & Wennberg, J. E. (1994) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199401000-00003 · Cited by 697
Roentgen stereophotogrammetry: A method for the study of the kinematics of the skeletal system
Selvik, G. (1989) · Acta Orthopaedica Scandinavica · doi:10.3109/17453678909154184 · Cited by 478
Friedman, C. D., Costantino, P. D., Takagi, S., & Chow, L. C. (1998) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(199824)43:4<428::aid-jbm10>3.0.co;2-0 · Cited by 418
Biomechanical and Histological Evaluation of a Calcium Phosphate Cement*
FRAKENBURG, E. P., GOLDSTEIN, S. A., BAUER, T. W., HARRIS, S. A., & POSER, R. D. (1998) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199808000-00004 · Cited by 362
Self-citationInterporous Hydroxyapatite as a Bone Graft Substitute in Tibial Plateau Fractures
BUCHOLZ, R. W., CARLTON, A., & HOLMES, R. (1989) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-198903000-00008 · Cited by 333
Norian SRS Cement Augmentation in Hip Fracture Treatment: Laboratory and Initial Clinical Results
Goodman, S. B., Bauer, T. W., Carter, D., Casteleyn, P. P., Goldstein, S. A., Kyle, R. F., Larsson, S., Stankewich, C. J., Swiontkowski, M. F., Tencer, A. F., et al. (1998) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199803000-00009 · Cited by 165
Self-citationKopylov, P., Runnqvist, K., Jonsson, K., & Aspenberg, P. (1999) · Acta Orthopaedica Scandinavica · doi:10.3109/17453679909000946 · Cited by 119
Yetkinler, D. N., Ladd, A. L., Poser, R. D., Constantz, B. R., & Carter, D. R. P. (1999) · Journal of Bone and Joint Surgery · doi:10.2106/00004623-199903000-00012 · Cited by 98
Cited by
Calcium phosphates in biomedical applications: materials for the future?
Habraken, W., Habibovic, P., Epple, M., & Bohner, M. (2016) · Materials Today · doi:10.1016/j.mattod.2015.10.008 · Cited by 857
Calcium phosphate cements as bone drug delivery systems: A review
Ginebra, M. P., Traykova, T., & Planell, J. A. (2006) · Journal of Controlled Release · doi:10.1016/j.jconrel.2006.04.007 · Cited by 684
Dorozhkin, S. V. (2007) · Journal of Materials Science · doi:10.1007/s10853-006-1467-8 · Cited by 573
Bone Grafts and Bone Graft Substitutes in Orthopaedic Trauma Surgery: A Critical Analysis
De Long, W. G., Einhorn, T. A., Koval, K., McKee, M., Smith, W., Sanders, R., & Watson, T. (2007) · The Journal of Bone & Joint Surgery · doi:10.2106/jbjs.f.00465 · Cited by 570
Biodegradable Materials for Bone Repairs: A Review
Tan, L., Yu, X., Wan, P., & Yang, K. (2013) · Journal of Materials Science & Technology · doi:10.1016/j.jmst.2013.03.002 · Cited by 431
Calcium phosphate cements for bone engineering and their biological properties
Xu, H. H., Wang, P., Wang, L., Bao, C., Chen, Q., Weir, M. D., Chow, L. C., Zhao, L., Zhou, X., & Reynolds, M. A. (2017) · Bone Research · doi:10.1038/boneres.2017.56 · Cited by 409
Review: Mineralization of Synthetic Polymer Scaffolds for Bone Tissue Engineering
Kretlow, J. D., & Mikos, A. G. (2007) · Tissue Engineering · doi:10.1089/ten.2006.0394 · Cited by 343
Calcium orthophosphate cements for biomedical application
Dorozhkin, S. V. (2008) · Journal of Materials Science · doi:10.1007/s10853-008-2527-z · Cited by 334
Calcium Orthophosphate Cements and Concretes
Dorozhkin, S. V. (2009) · Materials · doi:10.3390/ma2010221 · Cited by 221
“For further biomedical details, the interested readers are referred to other papers and reviews [21,25,32,33,111,391,395,477].”
BackgroundCalcium phosphate‐based composites as injectable bone substitute materials
Low, K. L., Tan, S. H., Zein, S. H. S., Roether, J. A., Mouriño, V., & Boccaccini, A. R. (2010) · Journal of Biomedical Materials Research Part B: Applied Biomaterials · doi:10.1002/jbm.b.31619 · Cited by 212
“Self-setting CPCs have been first expanded and many of them are already commercially available.(15,57,58) Recently, for use in minimal invasive surgery and as carriers for drug delivery systems, IBS are being developed based on the suspension of CP granules in a carrier phase consisting of polymeric water solution of…”
BackgroundGauthier, O., Müller, R., von Stechow, D., Lamy, B., Weiss, P., Bouler, J.-M., Aguado, E., & Daculsi, G. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2005.01.072 · Cited by 196
Guelcher, S. A., Srinivasan, A., Dumas, J. E., Didier, J. E., McBride, S., & Hollinger, J. O. (2008) · Biomaterials · doi:10.1016/j.biomaterials.2007.12.046 · Cited by 166
Synthesis of two-component injectable polyurethanes for bone tissue engineering
Bonzani, I. C., Adhikari, R., Houshyar, S., Mayadunne, R., Gunatillake, P., & Stevens, M. M. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2006.08.026 · Cited by 159
“Additionally, the polymers are found to exhibit mechanical properties better than those of a novel calcium phosphatebased bone cements and widely used acrylic cements, both of which have gained FDA and European approval for uses in distal radius and tibial plateau fractures, craniofacial applications, and screw fixati…”
Background
Metadata
- Authors
- Larsson, S., & Bauer, T. W.
- Venue
- Clinical Orthopaedics and Related Research
- Published
- 2002-02
- Volume
- 395
- Issue
- 395
- Pages
- 23-32
- ISSN
- 0009-921X (ISSN-L)
- OpenAlex
- W2053877801
- Cited by
- 257
- References
- 12
- FWCI
- 8.56
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.