Nonallograft Osteoconductive Bone Graft Substitutes
The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Abstract
An estimated 500,000 to 600,000 bone grafting procedures are done annually in the United States. Approximately (1/2) of these surgeries involve spinal arthrodesis whereas 35% to 40% are used for general orthopaedic applications. Synthetic bone graft substitutes currently represent only 10% of the bone graft market, but their share is increasing as experience and confidence in their use are accrued. Despite 15 to 20 years of clinical experience with various synthetic substitutes, there have been few welldesigned, controlled clinical trials of these implants. Synthetic bone graft substitutes consist of hydroxyapatite, tricalcium phosphate, calcium sulfate, or a combination of these minerals. Their fabrication technique, crystallinity, pore dimensions, mechanical properties, and resorption rate vary. All synthetic porous substitutes share numerous advantages over autografts and allografts including their unlimited supply, easy sterilization, and storage. However, the degree to which the substitute provides an osteoconductive structural framework or matrix for new bone ingrowth differs among implants. Disadvantages of ceramic implants include brittle handling properties, variable rates of resorption, poor performance in diaphyseal defects, and potentially adverse effects on normal bone remodeling. These inherent weaknesses have refocused their primary use to bone graft extenders and carriers for pharmaceuticals. The composition, histologic features, indications, and clinical experience of several of the synthetic bone graft substitutes approved for orthopaedic use in the United States are reviewed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STUDIES IN BONE GROWTH: TRIPLE CALCIUM PHOSPHATE AS A STIMULUS TO OSTEOGENESIS
ALBEE, F. H., & MORRISON, H. F. (1920) · Annals of Surgery · doi:10.1097/00000658-192001000-00006 · Cited by 376
Kelly, C. M., Wilkins, R. M., Gitelis, S., Hartjen, C., Watson, J. T., & Kim, P. T. (2001) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-200101000-00008 · Cited by 353
Interporous Hydroxyapatite as a Bone Graft Substitute in Tibial Plateau Fractures
BUCHOLZ, R. W., CARLTON, A., & HOLMES, R. (1989) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-198903000-00008 · Cited by 333
Self-citationPorous hydroxyapatite as a bone-graft substitute in metaphyseal defects. A histometric study.
Holmes, R. E., Bucholz, R. W., & Mooney, V (1986) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-198668060-00013 · Cited by 305
Self-citationCHAPMAN, M. W., BUCHOLZ, R., & CORNELL, C. (1997) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199704000-00004 · Cited by 228
Self-citationClark, A. E., Hench, L. L., & Paschall, H. A. (1976) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820100202 · Cited by 212
Moore, D. C., Chapman, M. W., & Manske, D. (1987) · Journal of Orthopaedic Research · doi:10.1002/jor.1100050307 · Cited by 164
Osteoblast adherence and resorption activity of isolated osteoclasts on calcium sulphate hemihydrate
Sidqui, M., Collin, P., Vitté, C., & Forest, N. (1995) · Biomaterials · doi:10.1016/0142-9612(95)91048-4 · Cited by 153
Multicenter Trial of Collagraft as Bone Graft Substitute
Cornell, C. N., Lane, J. M., Seligson, D., Henry, S., Chapman, M., Vincent, K., Merkow, R., & Gustilo, R. (1991) · Journal of Orthopaedic Trauma · doi:10.1097/00005131-199105020-00018 · Cited by 137
GRUNDEL, R. E., Chapman, M., Yee, T., & Moore, D. C. (1991) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199105000-00037 · Cited by 135
Cited by
Calcium phosphates in biomedical applications: materials for the future?
Habraken, W., Habibovic, P., Epple, M., & Bohner, M. (2016) · Materials Today · doi:10.1016/j.mattod.2015.10.008 · Cited by 857
Calcium phosphate cements for bone substitution: Chemistry, handling and mechanical properties
Zhang, J., Liu, W., Schnitzler, V., Tancret, F., & Bouler, J.-M. (2014) · Acta Biomaterialia · doi:10.1016/j.actbio.2013.11.001 · Cited by 667
Wagoner Johnson, A. J., & Herschler, B. A. (2011) · Acta Biomaterialia · doi:10.1016/j.actbio.2010.07.012 · Cited by 635
Recent Advances in Biomaterials for 3D Printing and Tissue Engineering
Jammalamadaka, U., & Tappa, K. (2018) · Journal of Functional Biomaterials · doi:10.3390/jfb9010022 · Cited by 526
Metallic Scaffolds for Bone Regeneration
Alvarez, K., & Nakajima, H. (2009) · Materials · doi:10.3390/ma2030790 · Cited by 505
Design of ceramic-based cements and putties for bone graft substitution
RMS Foundation, C.-2. B., & Bohner, M. (2010) · European Cells and Materials · doi:10.22203/ecm.v020a01 · Cited by 327
Ogose, A., Hotta, T., Kawashima, H., Kondo, N., Gu, W., Kamura, T., & Endo, N. (2005) · Journal of Biomedical Materials Research Part B: Applied Biomaterials · doi:10.1002/jbm.b.30136 · Cited by 315
Octacalcium phosphate: Osteoconductivity and crystal chemistry
Suzuki, O. (2010) · Acta Biomaterialia · doi:10.1016/j.actbio.2010.04.002 · Cited by 252
The Use of Osteoconductive Bone Graft Substitutes in Orthopaedic Trauma
Hak, D. J. (2007) · Journal of the American Academy of Orthopaedic Surgeons · doi:10.5435/00124635-200709000-00003 · Cited by 244
Extracellular matrix‐mimetic adhesive biomaterials for bone repair
Shekaran, A., & García, A. J. (2011) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.32979 · Cited by 234
“Furthermore, more than 600,000 bone grafting procedures are performed annually in the United States to treat nonhealing skeletal defects caused by traumatic injury and cancer.(8,9) However, autografts, the gold standard of treatment, are limited by donor site supply and morbidity,(10) and allografts are limited by inc…”
BackgroundEppley, B. L., Pietrzak, W. S., & Blanton, M. W. (2005) · Journal of Craniofacial Surgery · doi:10.1097/01.scs.0000179662.38172.dd · Cited by 231
“Coralline HA implants have been used for over 20 years for a variety of orthopedic, craniofacial, oral surgery, and periodontal procedures.(61,62,64,65) This interesting technology derives from the observation that certain marine corals, comprised primarily of calcium carbonate, have skeletons with interconnecting por…”
BackgroundMesenchymal Stem Cells and Bone Regeneration
KRAUS, K. H., & KIRKER‐HEAD, C. (2006) · Veterinary Surgery · doi:10.1111/j.1532-950x.2006.00142.x · Cited by 213
Kim, M. S., Ahn, H. H., Shin, Y. N., Cho, M. H., Khang, G., & Lee, H. B. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2007.08.014 · Cited by 205
Human stem cell delivery for treatment of large segmental bone defects
Dupont, K. M., Sharma, K., Stevens, H. Y., Boerckel, J. D., García, A. J., & Guldberg, R. E. (2010) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0905444107 · Cited by 197
Wang, L., Fan, H., Zhang, Z.-Y., Lou, A.-J., Pei, G.-X., Jiang, S., Mu, T.-W., Qin, J.-J., Chen, S.-Y., & Jin, D. (2010) · Biomaterials · doi:10.1016/j.biomaterials.2010.08.036 · Cited by 196
“transplantations are limited by several problems including limited supply, additional surgical time, donor sitemorbidity, long recovery period, and pathogen transfer [4,5].”
BackgroundSikavitsas, V. I., Bancroft, G. N., Lemoine, J. J., Liebschner, M. A. K., Dauner, M., & Mikos, A. G. (2005) · Annals of Biomedical Engineering · doi:10.1007/s10439-005-8963-x · Cited by 193
Bone Regeneration in Osseous Defects Using a Resorbable Nanoparticular Hydroxyapatite
Thorwarth, M., Schultze-Mosgau, S., Kessler, P., Wiltfang, J., & Schlegel, K. A. (2005) · Journal of Oral and Maxillofacial Surgery · doi:10.1016/j.joms.2005.06.010 · Cited by 193
Reactivity of calcium phosphate cements
Bohner, M. (2007) · Journal of Materials Chemistry · doi:10.1039/b706411j · Cited by 190
Shao, X., Goh, J. C. H., Hutmacher, D. W., Lee, E. H., & Zigang, G. (2006) · Tissue Engineering · doi:10.1089/ten.2006.12.1539 · Cited by 185
“21 However, because of the relatively poor mechanical properties, TCP is not suitable for load-bearing sites or large bony defects.”
Bone regeneration using an alpha 2 beta 1 integrin-specific hydrogel as a BMP-2 delivery vehicle
Shekaran, A., García, J. R., Clark, A. Y., Kavanaugh, T. E., Lin, A. S., Guldberg, R. E., & García, A. J. (2014) · Biomaterials · doi:10.1016/j.biomaterials.2014.03.055 · Cited by 183
Minardi, S., Corradetti, B., Taraballi, F., Sandri, M., Van Eps, J., Cabrera, F. J., Weiner, B. K., Tampieri, A., & Tasciotti, E. (2015) · Biomaterials · doi:10.1016/j.biomaterials.2015.05.011 · Cited by 175
“Autologous trabecular bone is widely regarded as the standard for bone augmentation, supplying growth factors, cells and a mechanical support for tissue’s structure [4, 5].”
BackgroundDíaz-Tocados, J. M., Herencia, C., Martínez-Moreno, J. M., Montes de Oca, A., Rodríguez-Ortiz, M. E., Vergara, N., Blanco, A., Steppan, S., Almadén, Y., Rodríguez, M., et al. (2017) · Scientific Reports · doi:10.1038/s41598-017-08379-y · Cited by 175
Uebersax, L., Apfel, T., Nuss, K. M. R., Vogt, R., Kim, H. Y., Meinel, L., Kaplan, D. L., Auer, J. A., Merkle, H. P., & von Rechenberg, B. (2013) · European Journal of Pharmaceutics and Biopharmaceutics · doi:10.1016/j.ejpb.2013.05.008 · Cited by 61
Metadata
- Authors
- Bucholz, R. W.
- Venue
- Clinical Orthopaedics and Related Research
- Published
- 2002-02
- Volume
- 395
- Issue
- 395
- Pages
- 44-52
- ISSN
- 0009-921X (ISSN-L)
- OpenAlex
- W2036127175
- Cited by
- 356
- References
- 10
- FWCI
- 13.80
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.