Experimental human endotoxemia increases cardiac regularity: Results from a prospective, randomized, crossover trial
The DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: To determine whether human endotoxemia is associated with a loss of the physiologic beat-to-beat variability of heart rate. DESIGN: Prospective, randomized, crossover, single-blind study. SETTING: Clinical research center in a federal, nonuniversity hospital. SUBJECTS: Healthy volunteers. INTERVENTIONS: Intravenous administration of reference (Escherichia coli) endotoxin or saline placebo, with or without previous administration of oral ibuprofen. MEASUREMENTS AND MAIN RESULTS: Electrocardiograms were continuously recorded and digitized using series of 1000 beat epochs of R-R intervals over 8 hrs. Analyses included measures in the time domain (standard deviation), frequency domain (power spectra), and a measure of regularity (approximate entropy). Endotoxin administration was associated with loss of variability by all measures. This loss of variability remained significant even with administration of ibuprofen, which blocked the development of fever and endotoxin-related symptoms. CONCLUSIONS: Infusion of endotoxin into human volunteers causes loss of heart rate variability, as measured by standard deviation and power spectra, as well as an increase in heart rate regularity, as measured by approximate entropy. Changes in approximate entropy occurred earlier than changes in other heart rate variability measures and may be a useful means of detecting early sepsis. This reduction in regularity is consistent with a model in which the pathogenesis of multiple organ system dysfunction syndrome involves the physiologic uncoupling of vital organ systems.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
An analysis of variance test for normality (complete samples)
SHAPIRO, S. S., & WILK, M. B. (1965) · Biometrika · doi:10.1093/biomet/52.3-4.591 · Cited by 23,480
A Real-Time QRS Detection Algorithm
Pan, J., & Tompkins, W. J. (1985) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1985.325532 · Cited by 7,855
Approximate entropy as a measure of system complexity.
Pincus, S. M. (1991) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.88.6.2297 · Cited by 5,811
Frequency domain measures of heart period variability and mortality after myocardial infarction
Bigger, J. T., Fleiss, J. L., Steinman, R. C., Rolnitzky, L. M., Kleiger, R. E., & Rottman, J. N. (1992) · Circulation · doi:10.1161/01.cir.85.1.164 · Cited by 1,712
Quantitative Investigation of QRS Detection Rules Using the MIT/BIH Arrhythmia Database
Hamilton, P. S., & Tompkins, W. J. (1986) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1986.325695 · Cited by 1,142
An Efficient Algorithm for Spectral Analysis of Heart Rate Variability
Berger, R. D., Akselrod, S., Gordon, D., & Cohen, R. J. (1986) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1986.325789 · Cited by 807
A regularity statistic for medical data analysis
Pincus, S. M., Gladstone, I. M., & Ehrenkranz, R. A. (1991) · Journal of Clinical Monitoring · doi:10.1007/bf01619355 · Cited by 788
Martich, G. D., Danner, R. L., Ceska, M., & Suffredini, A. F. (1991) · The Journal of Experimental Medicine · doi:10.1084/jem.173.4.1021 · Cited by 444
Self-citationPatterns of beat-to-beat heart rate variability in advanced heart failure
Woo, M. A., Stevenson, W. G., Moser, D. K., Trelease, R. B., & Harper, R. M. (1992) · American Heart Journal · doi:10.1016/0002-8703(92)90510-3 · Cited by 429
Godin, P. J., & Buchman, T. G. (1996) · Critical Care Medicine · doi:10.1097/00003246-199607000-00008 · Cited by 377
Self-citation
Cited by
Heart rate variability associated with particulate air pollution
Pope, C. A., Verrier, R. L., Lovett, E. G., Larson, A. C., Raizenne, M. E., Kanner, R. E., Schwartz, J., Villegas, G. M., Gold, D. R., & Dockery, D. W. (1999) · American Heart Journal · doi:10.1016/s0002-8703(99)70014-1 · Cited by 595
Complex systems and the technology of variability analysis
Seely, A. J., & Macklem, P. T. (2004) · Critical Care · doi:10.1186/cc2948 · Cited by 447
Acute Inflammatory Response to Endotoxin in Mice and Humans
Copeland, S., Warren, H. S., Lowry, S. F., Calvano, S. E., & Remick, D. (2005) · Clinical and Vaccine Immunology · doi:10.1128/cdli.12.1.60-67.2005 · Cited by 436
Godin, P. J., & Buchman, T. G. (1996) · Critical Care Medicine · doi:10.1097/00003246-199607000-00008 · Cited by 377
Self-citationSharshar, T., Gray, F., de la Grandmaison, G. L., Hopklnson, N. S., Ross, E., Dorandeu, A., Orlikowski, D., Raphael, J.-C., Gajdos, P., & Annane, D. (2003) · The Lancet · doi:10.1016/s0140-6736(03)14899-4 · Cited by 341
Griffin, M. P., & Moorman, J. R. (2001) · Pediatrics · doi:10.1542/peds.107.1.97 · Cited by 319
Inappropriate Sympathetic Activation at Onset of Septic Shock: A Spectral Analysis Approach
ANNANE, D., TRABOLD, F., SHARSHAR, T., JARRIN, I., BLANC, A. S., RAPHAEL, J. C., & GAJDOS, P. (1999) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.160.2.9810073 · Cited by 296
Multiple organ dysfunction syndrome: exploring the paradigm of complex nonlinear systems
Seely, A. J. E., & Christou, N. V. (2000) · Critical Care Medicine · doi:10.1097/00003246-200007000-00003 · Cited by 287
“(66) demonstrated a loss in HRV after intravenous endotoxin infusion in healthy humans; however, they do not remark on the fact that although endotoxin leads to decreased HRV, it is not sufficient to induce MODS in these healthy human volunteers.”
BackgroundBuchman, T. G. (2002) · Nature · doi:10.1038/nature01260 · Cited by 207
Self-citationUncoupling of the autonomic and cardiovascular systems in acute brain injury
Goldstein, B., Toweill, D., Lai, S., Sonnenthal, K., & Kimberly, B. (1998) · American Journal of Physiology-Regulatory, Integrative and Comparative Physiology · doi:10.1152/ajpregu.1998.275.4.r1287 · Cited by 196
Heart rate variability as early marker of multiple organ dysfunction syndrome in septic patients
Pontet, J., Contreras, P., Curbelo, A., Medina, J., Noveri, S., Bentancourt, S., & Migliaro, E. R. (2003) · Journal of Critical Care · doi:10.1016/j.jcrc.2003.08.005 · Cited by 195
Goldstein, B., Fiser, D. H., Kelly, M. M., Mickelsen, D., Ruttimann, U., & Pollack, M. M. (1998) · Critical Care Medicine · doi:10.1097/00003246-199802000-00040 · Cited by 183
Role of vasopressin in the management of septic shock
Mutlu, G., & Factor, P. (2004) · Intensive Care Medicine · doi:10.1007/s00134-004-2283-8 · Cited by 178
“Loss of autonomic nervous regulation has been reported in hyperdynamic states such as septic shock and portal hypertension [112, 113].”
BackgroundHeart rate variability after acute traumatic brain injury in children
Biswas, A. K., Scott, W. A., Sommerauer, J. F., & Luckett, P. M. (2000) · Critical Care Medicine · doi:10.1097/00003246-200012000-00030 · Cited by 176
“The ratio of low- to high-frequency (LF/HF) power was used as a measure of sympathetic modulation of heart rate (4, 5, 8, 15).”
MethodResultCardiac variability in critically ill adults: Influence of sepsis
Korach, M., Sharshar, T., Jarrin, I., Fouillot, J.-P., Raphaël, J.-C., Gajdos, P., & Annane, D. (2001) · Critical Care Medicine · doi:10.1097/00003246-200107000-00013 · Cited by 173
“This conclusion is supported by numerous controlled laboratory (1, 12) and clinical studies (3–5).”
BackgroundResultHeart Rate Variability in Emergency Department Patients with Sepsis
Barnaby, D., Ferrick, K., Kaplan, D. T., Shah, S., Bijur, P., & Gallagher, E. J. (2002) · Academic Emergency Medicine · doi:10.1197/aemj.9.7.661 · Cited by 167
Heart Rate Variability in Emergency Department Patients with Sepsis
Barnaby, D. P., Ferrick, K. J., Kaplan, D. T., Shah, S. P., Bijur, P. E., & Gallagher, E. J. (2002) · Academic Emergency Medicine · doi:10.1111/j.1553-2712.2002.tb02143.x · Cited by 167
Bench-to-bedside review: β-Adrenergic modulation in sepsis
de Montmollin, E., Aboab, J., Mansart, A., & Annane, D. (2009) · Critical Care · doi:10.1186/cc8026 · Cited by 158
“Sepsis is often characterized by altered cardiovascular variability, and particularly by impaired sympathetic control on heart and vessel tone [ 45-47 ].”
BackgroundYeatts, K., Svendsen, E., Creason, J., Alexis, N., Herbst, M., Scott, J., Kupper, L., Williams, R., Neas, L., Cascio, W., et al. (2007) · Environmental Health Perspectives · doi:10.1289/ehp.9499 · Cited by 158
Autonomic dysfunction in the ICU patient
Schmidt, H. B., Werdan, K., & Müller-Werdan, U. (2001) · Current Opinion in Critical Care · doi:10.1097/00075198-200110000-00002 · Cited by 138
Kox, M., Pompe, J. C., Pickkers, P., Hoedemaekers, C. W., van Vugt, A. B., & van der Hoeven, J. G. (2008) · Neurology · doi:10.1212/01.wnl.0000279479.69502.3e · Cited by 51
Metadata
- Authors
- Godin, P. J., Fleisher, L. A., Eidsath, A., Vandivier, R. W., Preas, H. L., Banks, S. M., Buchman, T. G., & Suffredini, A. F.
- Venue
- Critical Care Medicine
- Published
- 1996-07
- Volume
- 24
- Issue
- 7
- Pages
- 1117-1124
- ISSN
- 0090-3493 (ISSN-L)
- OpenAlex
- W2048750384
- Cited by
- 226
- References
- 26
- FWCI
- 7.23
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.