Abstract

OBJECTIVE: To assess the value of bioimpedance as a clinical tool by determining the accuracy and bias of single and multiple frequency bioimpedance estimates of total body and extracellular water in comparison with values established by criterion reference techniques. DESIGN: Controlled, prospective, single-blind investigation. SETTING: Private, not-for-profit, university-affiliated, acute care hospital. PATIENTS: Eight male, post-elective coronary artery bypass graft surgical patients. INTERVENTIONS: Within 6 hrs after surgery, estimates of total body and extracellular water volumes were determined using single and multiple frequency bioimpedance techniques. These estimates were then compared with the gold standard volumes measured by deuterium oxide and bromine dilutional space determination, respectively. MEASUREMENTS AND MAIN RESULTS: The mean multiple frequency bioimpedance estimate of total body water of 47.7 +/- 9.4 L was statistically different from the single frequency bioimpedance and deuterium values of 52.5 +/- 9.4 (p < .006) and 53.3 +/- 11.6 L (p < .002), respectively. In comparison, the mean multiple and single frequency bioimpedance estimates of extracellular water, 26.3 +/- 5.4 and 29.2 +/- 5.4 L, respectively, were not statistically different from the bromine value of 27.5 +/- 6.9 L. In addition, the mean errors for multiple and single frequency bioimpedance determinations of extracellular water, -1.2 +/- 2.0 and 1.7 +/- 2.7 L, respectively, were statistically different (p = .001). CONCLUSIONS: In male, post-elective coronary artery bypass graft surgical patients, single frequency bioimpedance was a more accurate and less biased predictor of total body water than multiple frequency bioimpedance. The accuracy and bias of multiple frequency bioimpedance was superior to single frequency bioimpedance for the prediction of extracellular water. Whether this observation remains true for other populations of critically ill patients remains to be investigated.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00003246-199611000-00011

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 67

Metadata

Authors
Patel, R. V., Peterson, E. L., Silverman, N., & Zarowitz, B. J.
Venue
Critical Care Medicine
Published
1996-11
Volume
24
Issue
11
Pages
1824-1828
ISSN
0090-3493 (ISSN-L)
OpenAlex
W2054312362
Cited by
67
References
3
FWCI
2.23
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Estimation of total body and extracellular water in post-coronary artery bypass graft surgical patients using single and multiple frequency bioimpedance. https://app.cochat.ai/papers/10.1097/00003246-199611000-00011
The paper
Patel, R. V., Peterson, E. L., Silverman, N., & Zarowitz, B. J. (1996). Estimation of total body and extracellular water in post-coronary artery bypass graft surgical patients using single and multiple frequency bioimpedance. Critical Care Medicine. https://doi.org/10.1097/00003246-199611000-00011

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.