Ultrasound guidance for placement of central venous catheters: A meta-analysis of the literature
The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: To evaluate the effect of real-time ultrasound guidance using a regular or Doppler ultrasound technique for placement of central venous catheters. DATA SOURCES: We searched for published and unpublished research using MEDLINE, citation review of relevant primary and review articles, conference abstracts, personal files, and contact with expert informants. STUDY SELECTION: From a pool of 208 randomized, controlled trials of venous and arterial catheter management, eight published randomized, controlled trials were identified. DATA EXTRACTION: In duplicate, independently, we abstracted data on the population, intervention, outcome, and methodologic quality. DATA SYNTHESIS: Ultrasound guidance significantly decreases internal jugular and subclavian catheter placement failure (relative risk 0.32; 95% confidence interval 0.18 to 0.55), decreases complications during catheter placement (relative risk 0.22; 95% confidence interval 0.10 to 0.45), and decreases the need for multiple catheter placement attempts (relative risk 0.60; 95% confidence interval 0.45 to 0.79) when compared with the standard landmark placement technique. CONCLUSIONS: When used for vessel location and catheter placement real-time, ultrasound guidance or Doppler ultrasound guidance improves success rates and decreases the complications associated with internal jugular and subclavian venous catheter placement.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Review papers : The statistical basis of meta-analysis
Fleiss, J. (1993) · Statistical Methods in Medical Research · doi:10.1177/096228029300200202 · Cited by 1,281
Complications and Failures of Subclavian-Vein Catheterization
Mansfield, P. F., Hohn, D. C., Fornage, B. D., Gregurich, M. A., & Ota, D. M. (1994) · New England Journal of Medicine · doi:10.1056/nejm199412293312602 · Cited by 713
Complications and Failures of Subclavian-Vein Catheterization
(1995) · New England Journal of Medicine · doi:10.1056/nejm199506083322313 · Cited by 626
Denys, B. G., Uretsky, B. F., & Reddy, P. S. (1993) · Circulation · doi:10.1161/01.cir.87.5.1557 · Cited by 543
Central Vein Catheterization: Failure and Complication Rates by Three Percutaneous Approaches
Sznajder, J. I. (1986) · Archives of Internal Medicine · doi:10.1001/archinte.1986.00360140065007 · Cited by 496
Subclavian Vein Catheterizations: A Prospective Study
BERNARD, R. W., & STAHL, W. M. (1971) · Annals of Surgery · doi:10.1097/00000658-197102000-00002 · Cited by 343
Ultrasound-Guided Cannulation of the Internal Jugular Vein. A Prospective, Randomized Study
Troianos, C. A., Jobes, D. R., & Ellison, N. (1991) · Anesthesia & Analgesia · doi:10.1213/00000539-199106000-00020 · Cited by 314
Anatomical variations of internal jugular vein location: Impact on central venous access
DENYS, B. G., & URETSKY, B. F. (1991) · Critical Care Medicine · doi:10.1097/00003246-199112000-00013 · Cited by 302
Ultrasound Guidance Improves the Success Rate of Internal Jugular Vein Cannulation
Mallory, D. L., McGee, W. T., Shawker, T. H., Brenner, M., Bailey, K. R., Evans, R. G., Parker, M. M., Farmer, J. C., & Parillo, J. E. (1990) · Chest · doi:10.1378/chest.98.1.157 · Cited by 264
Doppler Localization of the Internal Jugular Vein Facilitates Central Venous Cannulation
Legler, D. C., & Nugent, M. (1984) · Anesthesiology · doi:10.1097/00000542-198405000-00016 · Cited by 170
Gilbert, T. B., Seneff, M. G., & Becker, R. B. (1995) · Critical Care Medicine · doi:10.1097/00003246-199501000-00012 · Cited by 90
The SMART needle: A new Doppler ultrasound‐guided vascular access needle
Vucevic, M., TEHAN, B., Gamlin, F., BERRIDGE, J. C., & BOYLAN, M. (1994) · Anaesthesia · doi:10.1111/j.1365-2044.1994.tb04268.x · Cited by 55
Doppler-guided cannulation of the internal jugular vein: A prospective, randomized trial
Gratz, I., Afshar, M., Kidwell, P., Weiman, D. S., & Shariff, H. M. (1994) · Journal of Clinical Monitoring and Computing · doi:10.1007/bf02908859 · Cited by 37
[Continuous guidance for venous punctures using a new pulsed Doppler probe: efficiency, safety].
Branger, B., Zabadani, B., Vecina, F., Juan, J., & Dauzat, M. (1994) · PubMed · Cited by 15
Scherhag, A. W., Klein, A., & Jp, J. (1989) · PubMed · Cited by 11
Johnson, R., DONNELL, J. O., & Fielder, K. (1994) · Critical Care Medicine · doi:10.1097/00003246-199401000-00045 · Cited by 6
Cited by
Guidelines for the Prevention of Intravascular Catheter-related Infections
O'Grady, N. P., Alexander, M., Burns, L. A., Dellinger, E. P., Garland, J., Heard, S. O., Lipsett, P. A., Masur, H., Mermel, L. A., Pearson, M. L., et al. (2011) · Clinical Infectious Diseases · doi:10.1093/cid/cir257 · Cited by 4,699
Self-citationPreventing Complications of Central Venous Catheterization
McGee, D. C., & Gould, M. K. (2003) · New England Journal of Medicine · doi:10.1056/nejmra011883 · Cited by 2,290
Moore, C. L., & Copel, J. A. (2011) · New England Journal of Medicine · doi:10.1056/nejmra0909487 · Cited by 1,788
The incidence and nature of in-hospital adverse events: a systematic review
de Vries, E. N., Ramrattan, M. A., Smorenburg, S. M., Gouma, D. J., & Boermeester, M. A. (2008) · Quality and Safety in Health Care · doi:10.1136/qshc.2007.023622 · Cited by 1,784
Loveday, H. P., Wilson, J. A., Pratt, R. J., Golsorkhi, M., Tingle, A., Bak, A., Browne, J., Prieto, J., & Wilcox, M. (2014) · Journal of Hospital Infection · doi:10.1016/s0195-6701(13)60012-2 · Cited by 1,621
Metadata
- Authors
- Randolph, A. G., Cook, D. J., Gonzales, C. A., & Pribble, C. G.
- Venue
- Critical Care Medicine
- Published
- 1996-12
- Volume
- 24
- Issue
- 12
- Pages
- 2053-2058
- ISSN
- 0090-3493 (ISSN-L)
- OpenAlex
- W2011330050
- Cited by
- 852
- References
- 16
- FWCI
- 16.09
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.