Ultrasound guidance for placement of central venous catheters: A meta-analysis of the literature
The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: To evaluate the effect of real-time ultrasound guidance using a regular or Doppler ultrasound technique for placement of central venous catheters. DATA SOURCES: We searched for published and unpublished research using MEDLINE, citation review of relevant primary and review articles, conference abstracts, personal files, and contact with expert informants. STUDY SELECTION: From a pool of 208 randomized, controlled trials of venous and arterial catheter management, eight published randomized, controlled trials were identified. DATA EXTRACTION: In duplicate, independently, we abstracted data on the population, intervention, outcome, and methodologic quality. DATA SYNTHESIS: Ultrasound guidance significantly decreases internal jugular and subclavian catheter placement failure (relative risk 0.32; 95% confidence interval 0.18 to 0.55), decreases complications during catheter placement (relative risk 0.22; 95% confidence interval 0.10 to 0.45), and decreases the need for multiple catheter placement attempts (relative risk 0.60; 95% confidence interval 0.45 to 0.79) when compared with the standard landmark placement technique. CONCLUSIONS: When used for vessel location and catheter placement real-time, ultrasound guidance or Doppler ultrasound guidance improves success rates and decreases the complications associated with internal jugular and subclavian venous catheter placement.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Review papers : The statistical basis of meta-analysis
Fleiss, J. (1993) · Statistical Methods in Medical Research · doi:10.1177/096228029300200202 · Cited by 1,281
Complications and Failures of Subclavian-Vein Catheterization
Mansfield, P. F., Hohn, D. C., Fornage, B. D., Gregurich, M. A., & Ota, D. M. (1994) · New England Journal of Medicine · doi:10.1056/nejm199412293312602 · Cited by 713
Complications and Failures of Subclavian-Vein Catheterization
(1995) · New England Journal of Medicine · doi:10.1056/nejm199506083322313 · Cited by 626
Denys, B. G., Uretsky, B. F., & Reddy, P. S. (1993) · Circulation · doi:10.1161/01.cir.87.5.1557 · Cited by 543
Central Vein Catheterization: Failure and Complication Rates by Three Percutaneous Approaches
Sznajder, J. I. (1986) · Archives of Internal Medicine · doi:10.1001/archinte.1986.00360140065007 · Cited by 496
Subclavian Vein Catheterizations: A Prospective Study
BERNARD, R. W., & STAHL, W. M. (1971) · Annals of Surgery · doi:10.1097/00000658-197102000-00002 · Cited by 343
Ultrasound-Guided Cannulation of the Internal Jugular Vein. A Prospective, Randomized Study
Troianos, C. A., Jobes, D. R., & Ellison, N. (1991) · Anesthesia & Analgesia · doi:10.1213/00000539-199106000-00020 · Cited by 314
Anatomical variations of internal jugular vein location: Impact on central venous access
DENYS, B. G., & URETSKY, B. F. (1991) · Critical Care Medicine · doi:10.1097/00003246-199112000-00013 · Cited by 302
Ultrasound Guidance Improves the Success Rate of Internal Jugular Vein Cannulation
Mallory, D. L., McGee, W. T., Shawker, T. H., Brenner, M., Bailey, K. R., Evans, R. G., Parker, M. M., Farmer, J. C., & Parillo, J. E. (1990) · Chest · doi:10.1378/chest.98.1.157 · Cited by 264
Doppler Localization of the Internal Jugular Vein Facilitates Central Venous Cannulation
Legler, D. C., & Nugent, M. (1984) · Anesthesiology · doi:10.1097/00000542-198405000-00016 · Cited by 170
Cited by
Guidelines for the Prevention of Intravascular Catheter-related Infections
O'Grady, N. P., Alexander, M., Burns, L. A., Dellinger, E. P., Garland, J., Heard, S. O., Lipsett, P. A., Masur, H., Mermel, L. A., Pearson, M. L., et al. (2011) · Clinical Infectious Diseases · doi:10.1093/cid/cir257 · Cited by 4,699
Self-citationPreventing Complications of Central Venous Catheterization
McGee, D. C., & Gould, M. K. (2003) · New England Journal of Medicine · doi:10.1056/nejmra011883 · Cited by 2,290
Moore, C. L., & Copel, J. A. (2011) · New England Journal of Medicine · doi:10.1056/nejmra0909487 · Cited by 1,788
The incidence and nature of in-hospital adverse events: a systematic review
de Vries, E. N., Ramrattan, M. A., Smorenburg, S. M., Gouma, D. J., & Boermeester, M. A. (2008) · Quality and Safety in Health Care · doi:10.1136/qshc.2007.023622 · Cited by 1,784
Loveday, H. P., Wilson, J. A., Pratt, R. J., Golsorkhi, M., Tingle, A., Bak, A., Browne, J., Prieto, J., & Wilcox, M. (2014) · Journal of Hospital Infection · doi:10.1016/s0195-6701(13)60012-2 · Cited by 1,621
Merrer, J. (2001) · JAMA · doi:10.1001/jama.286.6.700 · Cited by 1,187
Ultrasonic locating devices for central venous cannulation: meta-analysis
Hind, D., Calvert, N., McWilliams, R., Davidson, A., Paisley, S., Beverley, C., & Thomas, S. (2003) · BMJ · doi:10.1136/bmj.327.7411.361 · Cited by 1,090
Guidelines for the prevention of intravascular catheter-related infections
O'Grady, N. P., Alexander, M., Burns, L. A., Dellinger, E. P., Garland, J., Heard, S. O., Lipsett, P. A., Masur, H., Mermel, L. A., Pearson, M. L., et al. (2011) · American Journal of Infection Control · doi:10.1016/j.ajic.2011.01.003 · Cited by 1,066
“pared with the standard landmark placement [60, 61].”
Self-citationInternational evidence-based recommendations on ultrasound-guided vascular access
Lamperti, M., Bodenham, A. R., Pittiruti, M., Blaivas, M., Augoustides, J. G., Elbarbary, M., Pirotte, T., Karakitsos, D., LeDonne, J., Doniger, S., et al. (2012) · Intensive Care Medicine · doi:10.1007/s00134-012-2597-x · Cited by 834
Guidelines for the Prevention of Intravascular Catheter-Related Infections
O’Grady, N. P., Alexander, M., Dellinger, E. P., Gerberding, J. L., Heard, S. O., Maki, D. G., Masur, H., McCormick, R. D., Mermel, L. A., Pearson, M. L., et al. (2002) · Pediatrics · doi:10.1542/peds.110.5.e51 · Cited by 738
Self-citationPratt, R. J., Pellowe, C. M., Wilson, J. A., Loveday, H. P., Harper, P. J., Jones, S. R. L. J., McDougall, C., & Wilcox, M. H. (2007) · Journal of Hospital Infection · doi:10.1016/s0195-6701(07)60002-4 · Cited by 725
Pittiruti, M., Hamilton, H., Biffi, R., MacFie, J., & Pertkiewicz, M. (2009) · Clinical Nutrition · doi:10.1016/j.clnu.2009.03.015 · Cited by 698
Guidelines for the use of platelet transfusions
Estcourt, L. J., Birchall, J., Allard, S., Bassey, S. J., Hersey, P., Kerr, J. P., Mumford, A. D., Stanworth, S. J., Tinegate, H., & the British Committee for Standards in Haematology (2017) · British Journal of Haematology · doi:10.1111/bjh.14423 · Cited by 648
Karakitsos, D., Labropoulos, N., De Groot, E., Patrianakos, A. P., Kouraklis, G., Poularas, J., Samonis, G., Tsoutsos, D. A., Konstadoulakis, M. M., & Karabinis, A. (2006) · Critical Care · doi:10.1186/cc5101 · Cited by 639
Ruesch, S., Walder, B., & Tramèr, M. R. (2002) · Critical Care Medicine · doi:10.1097/00003246-200202000-00031 · Cited by 629
O'Grady, N. P., Alexander, M., Burns, L. A., Dellinger, E. P., Garland, J., Heard, S. O., Lipsett, P. A., Masur, H., Mermel, L. A., Pearson, M. L., et al. (2011) · Clinical Infectious Diseases · doi:10.1093/cid/cir138 · Cited by 560
Self-citationReal-Time Ultrasound Guidance Facilitates Femoral Arterial Access and Reduces Vascular Complications
Seto, A. H., Abu-Fadel, M. S., Sparling, J. M., Zacharias, S. J., Daly, T. S., Harrison, A. T., Suh, W. M., Vera, J. A., Aston, C. E., Winters, R. J., et al. (2010) · JACC: Cardiovascular Interventions · doi:10.1016/j.jcin.2010.04.015 · Cited by 484
Ultrasound guidance versus anatomical landmarks for internal jugular vein catheterization
Brass, P., Hellmich, M., Kolodziej, L., Schick, G., & Smith, A. F. (2015) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd006962.pub2 · Cited by 476
Infections Associated with Medical Devices: Pathogenesis, Management and Prophylaxis
von Eiff, C., Jansen, B., Kohnen, W., & Becker, K. (2005) · Drugs · doi:10.2165/00003495-200565020-00003 · Cited by 459
Guidelines for the Prevention of Intravascular Catheter–Related Infections
O'Grady, N. P., Alexander, M., Dellinger, E. P., Gerberding, J. L., Heard, S. O., Maki, D. G., Masur, H., McCormick, R. D., Mermel, L. A., Pearson, M. L., et al. (2002) · Clinical Infectious Diseases · doi:10.1086/344188 · Cited by 440
Self-citationCostantino, T. G., Parikh, A. K., Satz, W. A., & Fojtik, J. P. (2005) · Annals of Emergency Medicine · doi:10.1016/j.annemergmed.2004.12.026 · Cited by 435
Barsuk, J. H., McGaghie, W. C., Cohen, E. R., Balachandran, J. S., & Wayne, D. B. (2009) · Journal of Hospital Medicine · doi:10.1002/jhm.468 · Cited by 405
The hemodialysis catheter conundrum: Hate living with them, but can’t live without them
Schwab, S. J., & Beathard, G. (1999) · Kidney International · doi:10.1046/j.1523-1755.1999.00512.x · Cited by 388
Central venous catheter use: Part 1: Mechanical complications
Polderman, K. H., & Girbes, A. R. (2002) · Intensive Care Medicine · doi:10.1007/s00134-001-1154-9 · Cited by 377
Schiffer, C. A., Mangu, P. B., Wade, J. C., Camp-Sorrell, D., Cope, D. G., El-Rayes, B. F., Gorman, M., Ligibel, J., Mansfield, P., & Levine, M. (2013) · Journal of Clinical Oncology · doi:10.1200/jco.2012.45.5733 · Cited by 368
Leung, J., Duffy, M., & Finckh, A. (2006) · Annals of Emergency Medicine · doi:10.1016/j.annemergmed.2006.01.011 · Cited by 342
Milling, T. J., Rose, J., Briggs, W. M., Birkhahn, R., Gaeta, T. J., Bove, J. J., & Melniker, L. A. (2005) · Critical Care Medicine · doi:10.1097/01.ccm.0000171533.92856.e5 · Cited by 334
Complications of Central Venous Catheterization
Kusminsky, R. E. (2007) · Journal of the American College of Surgeons · doi:10.1016/j.jamcollsurg.2007.01.039 · Cited by 330
Firstenberg, M., Kornbau, C., Lee, K., & Hughes, G. (2015) · International Journal of Critical Illness and Injury Science · doi:10.4103/2229-5151.164940 · Cited by 327
Ultrasound guidance versus anatomical landmarks for subclavian or femoral vein catheterization
Brass, P., Hellmich, M., Kolodziej, L., Schick, G., & Smith, A. F. (2015) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd011447 · Cited by 320
Guidelines for the Prevention of Intravascular Catheter–Related Infections
O'Grady, N. P., Alexander, M., Dellinger, E. P., Gerberding, J. L., Heard, S. O., Maki, D. G., Masur, H., McCormick, R. D., Mermel, L. A., Pearson, M. L., et al. (2002) · Infection Control & Hospital Epidemiology · doi:10.1017/s0195941700080577 · Cited by 319
Self-citationPneumothorax Following Thoracentesis: A Systematic Review and Meta-analysis
Gordon, C. E. (2010) · Archives of Internal Medicine · doi:10.1001/archinternmed.2009.548 · Cited by 306
Central venous catheterization
Taylor, R. W., & Palagiri, A. V. (2007) · Critical Care Medicine · doi:10.1097/01.ccm.0000260241.80346.1b · Cited by 299
Vascular Access in Oncology Patients
Gallieni, M., Pittiruti, M., & Biffi, R. (2008) · CA: A Cancer Journal for Clinicians · doi:10.3322/ca.2008.0015 · Cited by 284
Franco‐Sadud, R., Schnobrich, D., Mathews, B. K., Candotti, C., Abdel‐Ghani, S., Perez, M. G., Rodgers, S. C., Mader, M. J., Haro, E. K., Dancel, R., et al. (2019) · Journal of Hospital Medicine · doi:10.12788/jhm.3287 · Cited by 260
Froehlich, C. D., Rigby, M. R., Rosenberg, E. S., Li, R., Roerig, P.-L. J., Easley, K. A., & Stockwell, J. A. (2009) · Critical Care Medicine · doi:10.1097/ccm.0b013e31819b570e · Cited by 250
Continuous Renal-Replacement Therapy for Acute Kidney Injury
Tolwani, A. (2012) · New England Journal of Medicine · doi:10.1056/nejmct1206045 · Cited by 249
Injuries and Liability Related to Central Vascular Catheters: A Closed Claims Analysis
Domino, K. B., Bowdle, T. A., Posner, K. L., Spitellie, P. H., Lee, L. A., & Cheney, F. W. (2004) · Anesthesiology · doi:10.1097/00000542-200406000-00013 · Cited by 244
“to inconsistent efficacy of ultrasound in clinical trials in catheterization of the subclavian vein.(2,7,11,12) Injuries”
BackgroundBiffi, R., Orsi, F., Pozzi, S., Pace, U., Bonomo, G., Monfardini, L., Della Vigna, P., Rotmensz, N., Radice, D., Zampino, M. G., et al. (2009) · Annals of Oncology · doi:10.1093/annonc/mdn701 · Cited by 236
“The role of US guidance in catheterization of central veins was investigated in randomized trials, also included in two metaanalyses [9, 23].”
BackgroundMethodUltrasound guidance for difficult peripheral venous access: Systematic review and meta-analysis
Egan, G., Healy, D., O'Neill, H., Clarke-Moloney, M., Grace, P. A., & Walsh, S. R. (2013) · Emergency Medicine Journal · doi:10.1136/emermed-2012-201652 · Cited by 222
Lameire, N., Kellum, J. A., & for the KDIGO AKI Guideline Work Group (2013) · Critical Care · doi:10.1186/cc11455 · Cited by 219
“Th e advantage appears most pronounced for the jugular vein, whereas the evidence is scarce for the subclavian and femoral vein [110,111].”
BackgroundUltrasound-Guided Catheterization of the Radial Artery
Shiloh, A. L., Savel, R. H., Paulin, L. M., & Eisen, L. A. (2011) · Chest · doi:10.1378/chest.10-0919 · Cited by 208
Spencer, T. R., & Pittiruti, M. (2019) · The Journal of Vascular Access · doi:10.1177/1129729818804718 · Cited by 203
Pediatric emergency medicine point-of-care ultrasound: summary of the evidence
Marin, J. R., Abo, A. M., Arroyo, A. C., Doniger, S. J., Fischer, J. W., Rempell, R., Gary, B., Holmes, J. F., Kessler, D. O., Lam, S. H. F., et al. (2016) · Critical Ultrasound Journal · doi:10.1186/s13089-016-0049-5 · Cited by 190
Improvement of internal jugular vein cannulation using an ultrasound-guided technique
Slama, M., Novara, A., Safavian, A., Ossart, M., Safar, M., & Fagon, J.-Y. (1997) · Intensive Care Medicine · doi:10.1007/s001340050432 · Cited by 180
“A meta-analysis of the literature concerning ultrasound guidance for the placement of central venous catheters has recently been published [17].”
BackgroundA Prospective Comparison of Ultrasound-guided and Blindly Placed Radial Arterial Catheters
Shiver, S., Blaivas, M., & Lyon, M. (2006) · Academic Emergency Medicine · doi:10.1197/j.aem.2006.07.015 · Cited by 173
“A meta-analysis of the existing literature clearly showed that US guidance decreases central venous catheter placement failure rates, complications encountered during placement, and the need for multiple placement attempts.(4) Despite the success of US guidance in central access, less information exists on the applica…”
BackgroundUse of ultrasound to place central lines
Keenan, S. P. (2002) · Journal of Critical Care · doi:10.1053/jcrc.2002.34364 · Cited by 164
T. Arntfield, R., & J. Millington, S. (2012) · Current Cardiology Reviews · doi:10.2174/157340312801784952 · Cited by 164
“While ultrasound has gained widespread recognition for its ability to improve safety during central venous catheter insertion [117,118], the use of ultrasound to guide pericardiocentesis has also been extensively studied [119-121].”
BackgroundUltrasound-guidance vs. standard technique in difficult vascular access patients by ed technicians
Bauman, M., Braude, D., & Crandall, C. (2009) · The American Journal of Emergency Medicine · doi:10.1016/j.ajem.2008.02.005 · Cited by 160
Jenkins, K., & Baker, A. B. (2003) · Anaesthesia · doi:10.1046/j.1365-2044.2003.03410.x · Cited by 150
Au, A. K., Rotte, M. J., Grzybowski, R. J., Ku, B. S., & Fields, J. M. (2012) · The American Journal of Emergency Medicine · doi:10.1016/j.ajem.2012.04.016 · Cited by 149
“Ultrasound has previously been shown to decrease complication rates associated with CVC placement [12,13], and the current study reveals that the modality can further help avoid CVC placement altogether.”
BackgroundComplications of invasive monitoring
Bowdle, T. A. (2002) · Anesthesiology Clinics of North America · doi:10.1016/s0889-8537(02)00004-4 · Cited by 112
Metadata
- Authors
- Randolph, A. G., Cook, D. J., Gonzales, C. A., & Pribble, C. G.
- Venue
- Critical Care Medicine
- Published
- 1996-12
- Volume
- 24
- Issue
- 12
- Pages
- 2053-2058
- ISSN
- 0090-3493 (ISSN-L)
- OpenAlex
- W2011330050
- Cited by
- 852
- References
- 16
- FWCI
- 16.09
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.