CoChat

An open-label dose escalation study of the nitric oxide synthase inhibitor, NG-methyl-L-arginine hydrochloride (546C88), in patients with septic shock

Grover, Robert, Zaccardelli, David, Colice, Gene, Guntupalli, Kalpalatha, Watson, David, Vincent, Jean-Louis · 1999 · Critical Care Medicine
Cited by 198

The DOI matches its Crossref record; 45 of the 45 references it cites were found in a registry or an index.

Abstract

OBJECTIVE: To assess the effects of the nitric oxide synthase inhibitor, 546C88, in patients with septic shock and to evaluate the range of dose rates that sustain mean arterial pressure (MAP) of > or =70 mmHg. DESIGN: Multicenter, open-label, uncontrolled, dose range finding study. SETTING: Ten intensive care units in Europe and the United States. PATIENTS: Thirty-two patients with septic shock diagnosed within <24 hrs. INTERVENTIONS: Patients received a fixed dose rate of 546C88 at either 1(n = 6), 2.5 (n = 6), 5 (n = 4), 10 (n = 5), or 20 mg/kg/hr (n = 11) by intravenous infusion for up to 8 hrs. Conventional vasoactive therapy was restricted to norepinephrine and/or dobutamine. During 546C88 therapy, MAP was to be maintained between 70 and 90 mm Hg, while attempting to withdraw any concurrent norepinephrine. MEASUREMENTS AND MAIN RESULTS: Systemic and pulmonary hemodynamics, blood gases, and plasma nitrate were assessed. Infusion of 546C88 (1-20 mg/kg/hr) for up to 8 hrs enabled a 60 to 80% reduction of the norepinephrine dose rate in all cohorts, while MAP was sustained at >70 mm Hg. There was an increase in vascular tone and a decrease in cardiac index within the 1st hr of therapy. Systemic vascular resistance returned toward baseline with reduction of concomitant administration of norepinephrine. The decline in oxygen delivery was associated with an increase in extraction and, therefore, the maintenance of oxygen consumption. There was a sustained reduction of venous admixture within the 1st hr of therapy. 546C88 was not associated with any major or dose-dependent adverse effect on pulmonary, hepatic, or renal function. CONCLUSIONS: Treatment with the nitric oxide synthase inhibitor, 546C88, can restore the balance of vasomotor tone, thereby, maintaining blood pressure and reducing or eliminating the requirement for norepinephrine therapy in patients with septic shock. Infusion of 546C88 (1-20 mg/kg/hr) appears to have a satisfactory overall safety profile.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00003246-199905000-00025

Cites

45 of 45 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 45 references

Cited by

Metadata

Authors
Grover, R., Zaccardelli, D., Colice, G., Guntupalli, K., Watson, D., & Vincent, J.-L.
Venue
Critical Care Medicine
Published
1999-05
Volume
27
Issue
5
Pages
913-922
ISSN
0090-3493 (ISSN-L)
OpenAlex
W2053684366
Cited by
198
References
45
FWCI
19.90
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.