Reduced platelet activation and thrombosis in extracorporeal circuits coated with nitric oxide release polymers
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: To determine whether the use of nitric oxide (NO)-releasing polymers coated onto the inner surface of extracorporeal circuits can reduce platelet consumption and activation in the absence of systemic heparinization using a rabbit model of venovenous extracorporeal circulation. DESIGN: Prospective, controlled trial. SETTING: Research laboratory at an academic medical institution. SUBJECTS: New Zealand White Rabbits. INTERVENTIONS: Anesthetized, tracheotomized, and ventilated New Zealand White rabbits were injected with freshly prepared, 111In(oxine)3 labeled single donor platelets through the external jugular vein. After baseline measurements, these animals were placed on venovenous extracorporeal circulation through a 1-m control circuit or NO test circuit for 4 hrs at a blood flow rate of 109-118 mL/min via roller pump. Four groups were studied: systemically heparinized control circuits, systemically heparinized NO test circuits, nonheparinized control circuits, and nonheparinized NO test circuits. Platelet counts, fibrinogen levels, and plasma free indium levels were measured hourly. Circuits were rinsed and retained for gamma counting after the 4-hr run or when the circuit clotted. Four animals, one from each group, did not receive radiolabeled platelets so that the circuits could be preserved for scanning electron microscopic examination after the 4-hr study. MEASUREMENTS AND MAIN RESULTS: Platelet consumption was significantly reduced in both the heparinized and nonheparinized NO test groups when compared with the controls (p < .0001 and p < .0004, respectively). Platelet adhesion to the extracorporeal circuits was significantly reduced in the nonheparinized test circuits when compared with the controls (p < .05). Scanning electron microscopic examination of the circuits revealed that in the absence of heparin and in the presence of a NO-releasing surface, platelets retained their spherical nonactivated shape. CONCLUSIONS: The incorporation of NO into the surface of extracorporeal circuits reduces platelet consumption and eliminates the need for systemic heparinization in a rabbit model of extracorporeal circulation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Nitric Oxide-Releasing Polymers Containing the [N(O)NO]-Group
Smith, D. J., Chakravarthy, D., Pulfer, S., Simmons, M. L., Hrabie, J. A., Citro, M. L., Saavedra, J. E., Davies, K. M., Hutsell, T. C., Mooradian, D. L., et al. (1996) · Journal of Medicinal Chemistry · doi:10.1021/jm950652b · Cited by 208 · cited 1×
“(15) have shown that specific diazeniumdiolate NO donors can be incorporated into polymers to dramatically improve their biocompatibility.”
Background
Cited by
Recent developments in nitric oxide donor drugs
Miller, M. R., & Megson, I. L. (2007) · British Journal of Pharmacology · doi:10.1038/sj.bjp.0707224 · Cited by 628
Nitric Oxide Insufficiency, Platelet Activation, and Arterial Thrombosis
Loscalzo, J. (2001) · Circulation Research · doi:10.1161/hh0801.089861 · Cited by 612
Nitric Oxide Therapy for Diabetic Wound Healing
Malone‐Povolny, M. J., Maloney, S. E., & Schoenfisch, M. H. (2019) · Advanced Healthcare Materials · doi:10.1002/adhm.201801210 · Cited by 498
Frost, M. C., Reynolds, M. M., & Meyerhoff, M. E. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2004.06.006 · Cited by 343
Self-citationLarsson, M., Rayzman, V., Nolte, M. W., Nickel, K. F., Björkqvist, J., Jämsä, A., Hardy, M. P., Fries, M., Schmidbauer, S., Hedenqvist, P., et al. (2014) · Science Translational Medicine · doi:10.1126/scitranslmed.3006804 · Cited by 338
Metadata
- Authors
- Annich, G. M., Meinhardt, J. P., Mowery, K. A., Ashton, B. A., Merz, S. I., Hirschl, R. B., Meyerhoff, M. E., & Bartlett, R. H.
- Venue
- Critical Care Medicine
- Published
- 2000-04
- Volume
- 28
- Issue
- 4
- Pages
- 915-920
- ISSN
- 0090-3493 (ISSN-L)
- OpenAlex
- W2094682388
- Cited by
- 152
- References
- 1
- FWCI
- 8.08
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Reduced platelet activation and thrombosis in extracorporeal circuits coated with nitric oxide release polymers. https://app.cochat.ai/papers/10.1097/00003246-200004000-00001
- The paper
- Annich, G. M., Meinhardt, J. P., Mowery, K. A., Ashton, B. A., Merz, S. I., Hirschl, R. B., Meyerhoff, M. E., & Bartlett, R. H. (2000). Reduced platelet activation and thrombosis in extracorporeal circuits coated with nitric oxide release polymers. Critical Care Medicine. https://doi.org/10.1097/00003246-200004000-00001
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.