Reduced platelet activation and thrombosis in extracorporeal circuits coated with nitric oxide release polymers
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: To determine whether the use of nitric oxide (NO)-releasing polymers coated onto the inner surface of extracorporeal circuits can reduce platelet consumption and activation in the absence of systemic heparinization using a rabbit model of venovenous extracorporeal circulation. DESIGN: Prospective, controlled trial. SETTING: Research laboratory at an academic medical institution. SUBJECTS: New Zealand White Rabbits. INTERVENTIONS: Anesthetized, tracheotomized, and ventilated New Zealand White rabbits were injected with freshly prepared, 111In(oxine)3 labeled single donor platelets through the external jugular vein. After baseline measurements, these animals were placed on venovenous extracorporeal circulation through a 1-m control circuit or NO test circuit for 4 hrs at a blood flow rate of 109-118 mL/min via roller pump. Four groups were studied: systemically heparinized control circuits, systemically heparinized NO test circuits, nonheparinized control circuits, and nonheparinized NO test circuits. Platelet counts, fibrinogen levels, and plasma free indium levels were measured hourly. Circuits were rinsed and retained for gamma counting after the 4-hr run or when the circuit clotted. Four animals, one from each group, did not receive radiolabeled platelets so that the circuits could be preserved for scanning electron microscopic examination after the 4-hr study. MEASUREMENTS AND MAIN RESULTS: Platelet consumption was significantly reduced in both the heparinized and nonheparinized NO test groups when compared with the controls (p < .0001 and p < .0004, respectively). Platelet adhesion to the extracorporeal circuits was significantly reduced in the nonheparinized test circuits when compared with the controls (p < .05). Scanning electron microscopic examination of the circuits revealed that in the absence of heparin and in the presence of a NO-releasing surface, platelets retained their spherical nonactivated shape. CONCLUSIONS: The incorporation of NO into the surface of extracorporeal circuits reduces platelet consumption and eliminates the need for systemic heparinization in a rabbit model of extracorporeal circulation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Nitric Oxide-Releasing Polymers Containing the [N(O)NO]-Group
Smith, D. J., Chakravarthy, D., Pulfer, S., Simmons, M. L., Hrabie, J. A., Citro, M. L., Saavedra, J. E., Davies, K. M., Hutsell, T. C., Mooradian, D. L., et al. (1996) · Journal of Medicinal Chemistry · doi:10.1021/jm950652b · Cited by 208 · cited 1×
“(15) have shown that specific diazeniumdiolate NO donors can be incorporated into polymers to dramatically improve their biocompatibility.”
Background
Cited by
Recent developments in nitric oxide donor drugs
Miller, M. R., & Megson, I. L. (2007) · British Journal of Pharmacology · doi:10.1038/sj.bjp.0707224 · Cited by 628
Nitric Oxide Insufficiency, Platelet Activation, and Arterial Thrombosis
Loscalzo, J. (2001) · Circulation Research · doi:10.1161/hh0801.089861 · Cited by 612
Nitric Oxide Therapy for Diabetic Wound Healing
Malone‐Povolny, M. J., Maloney, S. E., & Schoenfisch, M. H. (2019) · Advanced Healthcare Materials · doi:10.1002/adhm.201801210 · Cited by 498
Frost, M. C., Reynolds, M. M., & Meyerhoff, M. E. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2004.06.006 · Cited by 343
Self-citationLarsson, M., Rayzman, V., Nolte, M. W., Nickel, K. F., Björkqvist, J., Jämsä, A., Hardy, M. P., Fries, M., Schmidbauer, S., Hedenqvist, P., et al. (2014) · Science Translational Medicine · doi:10.1126/scitranslmed.3006804 · Cited by 338
Combating medical device fouling
Harding, J. L., & Reynolds, M. M. (2014) · Trends in Biotechnology · doi:10.1016/j.tibtech.2013.12.004 · Cited by 261
Mowery, K. A., H. Schoenfisch, M., Saavedra, J. E., Keefer, L. K., & Meyerhoff, M. E. (2000) · Biomaterials · doi:10.1016/s0142-9612(99)00127-1 · Cited by 219
Self-citationPolymer‐Based Nitric Oxide Therapies: Recent Insights for Biomedical Applications
Jen, M. C., Serrano, M. C., van Lith, R., & Ameer, G. A. (2012) · Advanced Functional Materials · doi:10.1002/adfm.201101707 · Cited by 194
Progress Toward Clinical Application of the Nitric Oxide–Releasing Diazeniumdiolates
Keefer, L. K. (2003) · Annual Review of Pharmacology and Toxicology · doi:10.1146/annurev.pharmtox.43.100901.135831 · Cited by 189
Zhang, H., Annich, G. M., Miskulin, J., Stankiewicz, K., Osterholzer, K., Merz, S. I., Bartlett, R. H., & Meyerhoff, M. E. (2003) · Journal of the American Chemical Society · doi:10.1021/ja0291538 · Cited by 176
Self-citationZhang, H., Annich, G. M., Miskulin, J., Osterholzer, K., Merz, S. I., Bartlett, R. H., & Meyerhoff, M. E. (2002) · Biomaterials · doi:10.1016/s0142-9612(01)00274-5 · Cited by 168
“It will be further demonstrated that when such NO releasing materials are used to coat the inner walls of SR tubings employed for venovenous extracorporeal circulation of a rabbit [4], a significant reduction in the activation of platelets on the inner walls of the tubings is observed vs.”
BackgroundMethodInfluentialSelf-citationNovel thromboresistant materials
Jordan, S. W., & Chaikof, E. L. (2007) · Journal of Vascular Surgery · doi:10.1016/j.jvs.2007.02.048 · Cited by 153
Batchelor, M. M., Reoma, S. L., Fleser, P. S., Nuthakki, V. K., Callahan, R. E., Shanley, C. J., Politis, J. K., Elmore, J., Merz, S. I., & Meyerhoff, M. E. (2003) · Journal of Medicinal Chemistry · doi:10.1021/jm030286t · Cited by 120
Self-citationMajor, T. C., Brant, D. O., Burney, C. P., Amoako, K. A., Annich, G. M., Meyerhoff, M. E., Handa, H., & Bartlett, R. H. (2011) · Biomaterials · doi:10.1016/j.biomaterials.2011.03.036 · Cited by 118
“Indeed, a number of NO releasing (NORel) polymer coatings have been studied over the last decade using polymer-embedded NO donor molecules, such as diazeniumdiolated dibutylhexanediamine (DBHD/N2O2) [1–5].”
Self-citationReynolds, M. M., Frost, M. C., & Meyerhoff, M. E. (2004) · Free Radical Biology and Medicine · doi:10.1016/j.freeradbiomed.2004.06.019 · Cited by 116
Self-citationZhou, Z., & Meyerhoff, M. E. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2005.04.046 · Cited by 115
Self-citationBrisbois, E. J., Davis, R. P., Jones, A. M., Major, T. C., Bartlett, R. H., Meyerhoff, M. E., & Handa, H. (2015) · Journal of Materials Chemistry B · doi:10.1039/c4tb01839g · Cited by 101
Self-citationMajor, T. C., Brisbois, E. J., Jones, A. M., Zanetti, M. E., Annich, G. M., Bartlett, R. H., & Handa, H. (2014) · Biomaterials · doi:10.1016/j.biomaterials.2014.05.036 · Cited by 83
Self-citationImproved haemocompatibility of cysteine-modified polymers via endogenous nitric oxide
Duan, X., & Lewis, R. S. (2002) · Biomaterials · doi:10.1016/s0142-9612(01)00234-4 · Cited by 75
Nitric Oxide-Releasing Sol−Gel Particle/Polyurethane Glucose Biosensors
Shin, J. H., Marxer, S. M., & Schoenfisch, M. H. (2004) · Analytical Chemistry · doi:10.1021/ac049776z · Cited by 71
Harding, J. L., Metz, J. M., & Reynolds, M. M. (2014) · Advanced Functional Materials · doi:10.1002/adfm.201402529 · Cited by 67
Handa, H., Brisbois, E. J., Major, T. C., Refahiyat, L., Amoako, K. A., Annich, G. M., Bartlett, R. H., & Meyerhoff, M. E. (2013) · Journal of Materials Chemistry B · doi:10.1039/c3tb20277a · Cited by 64
Self-citationReynolds, M. M., & Annich, G. M. (2011) · Organogenesis · doi:10.4161/org.7.1.14029 · Cited by 60
Self-citationHarding, J. L., & Reynolds, M. M. (2014) · J. Mater. Chem. B · doi:10.1039/c3tb21458c · Cited by 43
Major, T. C., Handa, H., Annich, G. M., & Bartlett, R. H. (2014) · Journal of Biomaterials Applications · doi:10.1177/0885328214538866 · Cited by 43
“Two limitations with ECC circuits that strongly activate circulating platelets and reduce platelet count are the adsorption of fibrinogen to the biomaterial surface and the required need for systemic anticoagulation with heparin which has minimal effect on platelet activation or no reduction on fibrinogen adsorption.(…”
BackgroundSelf-citationNO donors and NO delivery methods for controlling biofilms in chronic lung infections
Cai, Y.-M., Zhang, Y.-D., & Yang, L. (2021) · Applied Microbiology and Biotechnology · doi:10.1007/s00253-021-11274-2 · Cited by 25
Höfler, L., Koley, D., Wu, J., Xi, C., & Meyerhoff, M. E. (2012) · RSC Advances · doi:10.1039/c2ra20853a · Cited by 20
Self-citationSynthesis of novel N-diazeniumdiolates based on hyperbranched polyethers
Kou, Y., & Wan, A. (2008) · Bioorganic & Medicinal Chemistry Letters · doi:10.1016/j.bmcl.2008.02.073 · Cited by 7
Metadata
- Authors
- Annich, G. M., Meinhardt, J. P., Mowery, K. A., Ashton, B. A., Merz, S. I., Hirschl, R. B., Meyerhoff, M. E., & Bartlett, R. H.
- Venue
- Critical Care Medicine
- Published
- 2000-04
- Volume
- 28
- Issue
- 4
- Pages
- 915-920
- ISSN
- 0090-3493 (ISSN-L)
- OpenAlex
- W2094682388
- Cited by
- 152
- References
- 1
- FWCI
- 8.08
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.